1
0
Fork 0
Commit graph

9 commits

Author SHA1 Message Date
curt
11e112c1e4 Added very simplistic volt and amp modeling to the electrical model. This
should really be made more generic and part of the electrical model config
but this is all I had time for this weekend.
2003-05-27 19:18:14 +00:00
curt
198b88ca9b This is step "1" of probably "many" in the process of separating out the
scene management code and organizing it within simgear.  My strategy is
to identify the code I want to move, and break it's direct flightgear
dependencies.  Then it will be free to move over into the simgear package.

- Moved some property specific code into simgear/props/
- Split out the condition code from fgfs/src/Main/fg_props and put it
  in it's own source file in simgear/props/
- Created a scene subdirectory for scenery, model, and material property
  related code.
- Moved location.[ch]xx into simgear/scene/model/
- The location and condition code had dependencies on flightgear's global
  state (all the globals-> stuff, the flightgear property tree, etc.)  SimGear
  code can't depend on it so that data has to be passed as parameters to the
  functions/methods/constructors.
- This need to pass data as function parameters had a dramatic cascading
  effect throughout the FlightGear code.
2003-05-06 23:54:17 +00:00
curt
6bfdb5a762 Add support for specifying an rpm source for the alternator. This enables
us to tie the output of an arbitrary generator to the state of an arbitrary
engine.
2003-02-03 22:35:24 +00:00
curt
1b40b5e4c9 Fixed a spelling error in the api. (ouch) :-) 2003-02-03 22:22:02 +00:00
curt
9e35d33657 Add the ability to specify an initial state (on/off) for a connector switch.
If nothing is specifed the switch defaults to on, but this is a problem for
the starter switch.
2003-02-03 22:15:36 +00:00
curt
cc4821e43f Each node in the electrical system graph can now publish to an arbitrary
number of properties which will reflect that node's state.
2002-09-26 04:51:23 +00:00
curt
8d2014f7bc Updates to the electrical system model. "Juice" is now propogated through
the system, switches, fuses, circuit-breakers work.  Nothing is actually
wired into the electical system yet.
2002-09-24 23:45:56 +00:00
curt
3323efa256 Check point commit:
The code reads the electrical system config and contructs an internal model.
Nothing is done beyond that yet ... the electrical system is not updated,
nor is it connected to the property system in anyway.
2002-09-24 19:57:11 +00:00
curt
90e64f9430 Stub in a place holder for the electrical system model. 2002-09-24 15:24:04 +00:00