2020-05-05 18:12:14 +00:00
<!-- Copyright (c) 2019 Jonathan Redpath (legoboyvdlp) -->
<system name= "A320: Pneumatic" >
2020-07-19 13:01:13 +00:00
<channel name= "Startup" execrate= "8" >
2020-05-26 20:33:26 +00:00
<switch name= "/systems/startup-power-valves" >
<default value= "0" />
<test logic= "AND" value= "1" >
/sim/time/elapsed-sec lt 10
</test>
</switch>
</channel>
2020-07-19 13:01:13 +00:00
<channel name= "Valves" execrate= "8" >
2020-05-05 18:12:14 +00:00
2020-05-05 18:43:21 +00:00
<!-- apu -->
<switch name= "/systems/pneumatics/valves/apu-bleed-valve-cmd" >
<default value= "0" />
<test logic= "AND" value= "1" >
/engines/engine[2]/n1 ge 95
/controls/pneumatics/switches/apu eq 1
</test>
</switch>
<switch name= "/systems/pneumatics/valves/apu-bleed-valve-power" >
<default value= "0" />
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "1" >
/systems/startup-power-valves eq 1
</test>
<test logic= "AND" value= "1" >
2020-05-06 20:34:08 +00:00
/systems/failures/pneumatics/apu-valve eq 0
2020-05-05 18:43:21 +00:00
/systems/electrical/bus/dc-ess-shed ge 25
<!-- confirm, some a320 have it on dc - bat, but this makes sense, since x - bleed is on ess shed too.
Definitely, some A320 have it on dc-ess-shed, but why is there any difference? -->
</test>
</switch>
<actuator name= "/systems/pneumatics/valves/apu-bleed-valve" >
<input > /systems/pneumatics/valves/apu-bleed-valve-cmd</input>
<rate_limit > /systems/pneumatics/valves/apu-bleed-valve-power</rate_limit>
</actuator>
2020-05-06 16:05:53 +00:00
<!-- Crossbleed -->
<switch name= "/systems/pneumatics/valves/crossbleed-valve-cmd" >
<default value= "/systems/pneumatics/valves/crossbleed-valve-cmd" />
<test logic= "AND" value= "0" > <!-- CB 2HV -->
/systems/electrical/bus/dc-ess-shed ge 25
/controls/pneumatics/switches/x-bleed eq 0
</test>
<test logic= "AND" value= "1" >
/systems/electrical/bus/dc-ess-shed ge 25
/controls/pneumatics/switches/x-bleed eq 2
</test>
<test logic= "AND" value= "0" > <!-- CB 1HV, 4HV -->
/systems/electrical/bus/dc-2 ge 25
<test logic= "OR" >
/controls/pneumatics/switches/apu eq 0
/systems/pneumatics/valves/apu-bleed-valve eq 0
</test>
</test>
<test logic= "AND" value= "1" > <!-- CB 1HV, 4HV -->
/systems/electrical/bus/dc-2 ge 25
/controls/pneumatics/switches/apu eq 1
/systems/pneumatics/valves/apu-bleed-valve ne 0
</test>
</switch>
<switch name= "/systems/pneumatics/valves/crossbleed-valve-power" >
<default value= "0" />
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "1" >
/systems/startup-power-valves eq 1
</test>
2020-05-06 20:34:08 +00:00
<test logic= "AND" value= "0.2" >
/systems/failures/pneumatics/x-bleed-valve eq 0
<test logic= "OR" >
/systems/electrical/bus/dc-ess-shed ge 25
/systems/electrical/bus/dc-2 ge 25
</test>
2020-05-06 16:05:53 +00:00
</test>
</switch>
<actuator name= "/systems/pneumatics/valves/crossbleed-valve" >
<input > /systems/pneumatics/valves/crossbleed-valve-cmd</input>
<rate_limit > /systems/pneumatics/valves/crossbleed-valve-power</rate_limit>
</actuator>
2020-05-05 18:12:14 +00:00
<!-- Low Pressure valve -->
<switch name= "/systems/pneumatics/valves/engine-1-lp-valve-cmd" >
<default value= "1" />
<test logic= "OR" value= "0" >
/systems/pneumatics/valves/engine-1-hp-valve eq 1
</test>
</switch>
2020-05-05 18:43:21 +00:00
<switch name= "/systems/pneumatics/valves/engine-1-lp-valve-power" >
2020-05-05 18:12:14 +00:00
<default value= "0" />
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "1" >
/systems/startup-power-valves eq 1
</test>
2020-05-11 20:25:40 +00:00
<test logic= "OR" value= "1" > <!-- pneumatic, so instant nearly -->
2020-05-05 18:12:14 +00:00
/systems/electrical/bus/dc-ess-shed ge 25
</test>
</switch>
2020-05-11 20:25:40 +00:00
<switch name= "/systems/pneumatics/valves/engine-1-lp-valve" >
<default value= "/systems/pneumatics/valves/engine-1-lp-valve-cmd" />
<test value= "/systems/pneumatics/valves/engine-1-lp-valve" >
/systems/pneumatics/valves/engine-1-lp-valve-power eq 0
</test>
</switch>
2020-05-05 18:12:14 +00:00
<switch name= "/systems/pneumatics/valves/engine-2-lp-valve-cmd" >
<default value= "1" />
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "1" >
/systems/startup-power-valves eq 1
</test>
2020-05-05 18:12:14 +00:00
<test logic= "OR" value= "0" >
/systems/pneumatics/valves/engine-2-hp-valve eq 1
</test>
</switch>
2020-05-05 18:43:21 +00:00
<switch name= "/systems/pneumatics/valves/engine-2-lp-valve-power" >
2020-05-05 18:12:14 +00:00
<default value= "0" />
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "1" >
/systems/startup-power-valves eq 1
</test>
2020-05-11 20:25:40 +00:00
<test logic= "OR" value= "1" > <!-- pneumatic, so instant nearly -->
2020-05-05 18:12:14 +00:00
/systems/electrical/bus/dc-2 ge 25
</test>
</switch>
2020-05-11 20:25:40 +00:00
<switch name= "/systems/pneumatics/valves/engine-2-lp-valve" >
<default value= "/systems/pneumatics/valves/engine-2-lp-valve-cmd" />
<test value= "/systems/pneumatics/valves/engine-2-lp-valve" >
/systems/pneumatics/valves/engine-2-lp-valve-power eq 0
</test>
</switch>
2020-05-05 18:12:14 +00:00
<!-- High Pressure valve -->
<switch name= "/systems/pneumatics/valves/engine-1-hp-valve-cmd" >
<default value= "1" />
<test logic= "OR" value= "0" >
/systems/pneumatics/source/engine-1-hp-psi lt 8
/systems/pneumatics/source/engine-1-hp-psi ge 120
<test logic= "AND" >
2020-05-11 14:57:23 +00:00
/systems/pneumatics/valves/wing-ice-1 eq 0
2020-05-05 18:12:14 +00:00
/systems/pneumatics/source/engine-1-hp-psi ge 110
/position/altitude-ft ge 15000
/systems/pneumatics/valves/engine-1-prv-valve eq 1
/systems/pneumatics/valves/engine-2-prv-valve eq 1
</test>
</test>
</switch>
2020-05-05 18:43:21 +00:00
<switch name= "/systems/pneumatics/valves/engine-1-hp-valve-power" >
2020-05-05 18:12:14 +00:00
<default value= "0" />
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "1" >
/systems/startup-power-valves eq 1
</test>
2020-05-11 20:25:40 +00:00
<test logic= "AND" value= "1" >
2020-05-05 18:12:14 +00:00
/systems/electrical/bus/dc-ess-shed ge 25
2020-05-06 20:34:08 +00:00
/systems/failures/pneumatics/hp-1-valve eq 0
2020-05-05 18:12:14 +00:00
</test>
</switch>
2020-05-11 20:25:40 +00:00
<switch name= "/systems/pneumatics/valves/engine-1-hp-valve" >
<default value= "/systems/pneumatics/valves/engine-1-hp-valve-cmd" />
<test value= "/systems/pneumatics/valves/engine-1-hp-valve" >
/systems/pneumatics/valves/engine-1-hp-valve-power eq 0
</test>
</switch>
2020-05-05 18:12:14 +00:00
<switch name= "/systems/pneumatics/valves/engine-2-hp-valve-cmd" >
<default value= "1" />
<test logic= "OR" value= "0" >
/systems/pneumatics/source/engine-2-hp-psi lt 8
/systems/pneumatics/source/engine-2-hp-psi ge 120
<test logic= "AND" >
2020-05-11 14:57:23 +00:00
/systems/pneumatics/valves/wing-ice-2 eq 0
2020-05-05 18:12:14 +00:00
/systems/pneumatics/source/engine-2-hp-psi ge 110
/position/altitude-ft ge 15000
/systems/pneumatics/valves/engine-1-prv-valve eq 1
/systems/pneumatics/valves/engine-2-prv-valve eq 1
</test>
</test>
</switch>
2020-05-05 18:43:21 +00:00
<switch name= "/systems/pneumatics/valves/engine-2-hp-valve-power" >
2020-05-05 18:12:14 +00:00
<default value= "0" />
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "1" >
/systems/startup-power-valves eq 1
</test>
2020-05-11 20:25:40 +00:00
<test logic= "AND" value= "1" >
2020-05-05 18:12:14 +00:00
/systems/electrical/bus/dc-2 ge 25
2020-05-06 20:34:08 +00:00
/systems/failures/pneumatics/hp-2-valve eq 0
2020-05-05 18:12:14 +00:00
</test>
</switch>
2020-05-11 20:25:40 +00:00
<switch name= "/systems/pneumatics/valves/engine-2-hp-valve" >
<default value= "/systems/pneumatics/valves/engine-2-hp-valve-cmd" />
<test value= "/systems/pneumatics/valves/engine-2-hp-valve" >
/systems/pneumatics/valves/engine-2-hp-valve-power eq 0
</test>
</switch>
2020-05-05 18:12:14 +00:00
<!-- Pressure regulation valve -->
2020-05-11 12:08:55 +00:00
<switch name= "/systems/pneumatics/valves/engine-1-prv-valve-autoclose-psi-cmd" >
<default value= "0" />
<test value= "1" >
/systems/pneumatics/psi/engine-1-downstream-prv gt 57
</test>
</switch>
<actuator name= "/systems/pneumatics/valves/engine-1-prv-valve-autoclose-psi" >
<input > /systems/pneumatics/valves/engine-1-prv-valve-autoclose-psi-cmd</input>
2020-10-20 21:24:29 +00:00
<rate_limit sense= "decr" > 120</rate_limit> <!-- Instant -->
2020-05-11 12:08:55 +00:00
<rate_limit sense= "incr" > 0.0666</rate_limit> <!-- 15 seconds -->
</actuator>
2020-05-10 22:58:26 +00:00
<switch name= "/systems/pneumatics/valves/engine-1-prv-valve-autoclose-cmd" >
<default value= "0" />
2020-05-11 12:08:55 +00:00
<test logic= "AND" value= "1" >
/systems/pneumatics/valves/engine-1-prv-valve-autoclose-cmd eq 1
/controls/pneumatics/switches/bleed-1 eq 1
</test>
2020-05-10 22:58:26 +00:00
<test logic= "OR" value= "1" >
2020-05-11 12:08:55 +00:00
/systems/pneumatics/valves/engine-1-prv-valve-autoclose-psi eq 1
2020-05-10 22:58:26 +00:00
/systems/pneumatics/precooler/ovht-1 eq 1
</test>
</switch>
2020-05-11 12:08:55 +00:00
<fcs_function name= "/systems/pneumatics/valves/engine-1-prv-valve-temp-gain" >
<function >
<table >
<independentVar lookup= "row" > /systems/pneumatics/precooler/temp-1</independentVar>
<tableData >
235 1.0
245 0.397
</tableData>
</table>
</function>
</fcs_function>
2020-05-05 18:12:14 +00:00
<switch name= "/systems/pneumatics/valves/engine-1-prv-valve-cmd" >
<default value= "0" />
<test logic= "OR" value= "0" >
/controls/engines/engine[0]/fire-btn eq 1
2020-05-10 22:58:26 +00:00
/controls/pneumatics/switches/bleed-1 eq 0
2020-06-16 17:51:43 +00:00
/systems/pneumatics/valves/apu-bleed-valve eq 1
2020-05-11 12:08:55 +00:00
/systems/pneumatics/valves/starter-valve-1 ne 0
2020-05-26 20:33:26 +00:00
/systems/pneumatics/psi/engine-1-upstream-src lt 8
2020-05-10 22:58:26 +00:00
/systems/pneumatics/valves/engine-1-prv-valve-autoclose-cmd eq 1
2020-05-05 18:12:14 +00:00
</test>
2020-05-11 12:08:55 +00:00
<test logic= "AND" value= "/systems/pneumatics/valves/engine-1-prv-valve-temp-gain" >
2020-05-05 18:12:14 +00:00
/controls/pneumatics/switches/bleed-1 eq 1
</test>
</switch>
2020-05-05 18:43:21 +00:00
<switch name= "/systems/pneumatics/valves/engine-1-prv-valve-power" >
2020-05-05 18:12:14 +00:00
<default value= "0" />
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "1" >
/systems/startup-power-valves eq 1
</test>
<test logic= "AND" value= "1" >
2020-05-05 18:12:14 +00:00
/systems/electrical/bus/dc-ess-shed ge 25
/systems/failures/pneumatics/bleed-1-valve eq 0
</test>
</switch>
<actuator name= "/systems/pneumatics/valves/engine-1-prv-valve" >
<input > /systems/pneumatics/valves/engine-1-prv-valve-cmd</input>
2020-05-05 18:43:21 +00:00
<rate_limit > /systems/pneumatics/valves/engine-1-prv-valve-power</rate_limit>
2020-05-05 18:12:14 +00:00
</actuator>
2020-05-06 16:05:53 +00:00
<switch name= "/systems/pneumatics/valves/engine-1-prv-valve-disag" >
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/pneumatics/valves/engine-1-prv-valve-cmd eq 0
/systems/pneumatics/valves/engine-1-prv-valve ne 0
</test>
<test logic= "AND" value= "1" >
/systems/pneumatics/valves/engine-1-prv-valve-cmd eq 1
/systems/pneumatics/valves/engine-1-prv-valve ne 1
</test>
</switch>
2020-05-11 12:08:55 +00:00
<switch name= "/systems/pneumatics/valves/engine-2-prv-valve-autoclose-psi-cmd" >
<default value= "0" />
<test value= "1" >
/systems/pneumatics/psi/engine-2-downstream-prv gt 57
</test>
</switch>
<actuator name= "/systems/pneumatics/valves/engine-2-prv-valve-autoclose-psi" >
<input > /systems/pneumatics/valves/engine-2-prv-valve-autoclose-psi-cmd</input>
2020-10-20 21:24:29 +00:00
<rate_limit sense= "decr" > 120</rate_limit> <!-- Instant -->
2020-05-11 12:08:55 +00:00
<rate_limit sense= "incr" > 0.0666</rate_limit> <!-- 15 seconds -->
</actuator>
2020-05-10 22:58:26 +00:00
<switch name= "/systems/pneumatics/valves/engine-2-prv-valve-autoclose-cmd" >
<default value= "0" />
2020-05-11 12:08:55 +00:00
<test logic= "AND" value= "1" >
/systems/pneumatics/valves/engine-2-prv-valve-autoclose-cmd eq 1
/controls/pneumatics/switches/bleed-2 eq 1
</test>
2020-05-10 22:58:26 +00:00
<test logic= "OR" value= "1" >
2020-05-11 12:08:55 +00:00
/systems/pneumatics/valves/engine-2-prv-valve-autoclose-psi eq 1
2020-05-10 22:58:26 +00:00
/systems/pneumatics/precooler/ovht-2 eq 1
</test>
</switch>
2020-05-11 12:08:55 +00:00
<fcs_function name= "/systems/pneumatics/valves/engine-2-prv-valve-temp-gain" >
<function >
<table >
<independentVar lookup= "row" > /systems/pneumatics/precooler/temp-2</independentVar>
<tableData >
235 1.0
245 0.397
</tableData>
</table>
</function>
</fcs_function>
2020-05-05 18:12:14 +00:00
<switch name= "/systems/pneumatics/valves/engine-2-prv-valve-cmd" >
<default value= "0" />
<test logic= "OR" value= "0" >
/controls/engines/engine[1]/fire-btn eq 1
2020-05-10 22:58:26 +00:00
/controls/pneumatics/switches/bleed-2 eq 0
2020-05-12 20:57:10 +00:00
<test logic= "AND" >
2020-06-16 17:51:43 +00:00
/systems/pneumatics/valves/apu-bleed-valve eq 1
2020-05-12 20:57:10 +00:00
/systems/pneumatics/valves/crossbleed-valve ne 0
</test>
2020-05-11 12:08:55 +00:00
/systems/pneumatics/valves/starter-valve-2 ne 0
2020-05-26 20:33:26 +00:00
/systems/pneumatics/psi/engine-2-upstream-src lt 8
2020-05-10 22:58:26 +00:00
/systems/pneumatics/valves/engine-2-prv-valve-autoclose-cmd eq 1
2020-05-05 18:12:14 +00:00
</test>
2020-05-11 12:08:55 +00:00
<test logic= "AND" value= "/systems/pneumatics/valves/engine-2-prv-valve-temp-gain" >
2020-05-05 18:12:14 +00:00
/controls/pneumatics/switches/bleed-2 eq 1
</test>
</switch>
2020-05-05 18:43:21 +00:00
<switch name= "/systems/pneumatics/valves/engine-2-prv-valve-power" >
2020-05-05 18:12:14 +00:00
<default value= "0" />
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "1" >
/systems/startup-power-valves eq 1
</test>
<test logic= "AND" value= "1" >
2020-05-05 18:12:14 +00:00
/systems/electrical/bus/dc-2 ge 25
/systems/failures/pneumatics/bleed-2-valve eq 0
</test>
</switch>
2020-05-06 16:05:53 +00:00
<switch name= "/systems/pneumatics/valves/engine-2-prv-valve-disag" >
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/pneumatics/valves/engine-2-prv-valve-cmd eq 0
/systems/pneumatics/valves/engine-2-prv-valve ne 0
</test>
<test logic= "AND" value= "1" >
/systems/pneumatics/valves/engine-2-prv-valve-cmd eq 1
/systems/pneumatics/valves/engine-2-prv-valve ne 1
</test>
</switch>
2020-05-05 18:12:14 +00:00
<actuator name= "/systems/pneumatics/valves/engine-2-prv-valve" >
<input > /systems/pneumatics/valves/engine-2-prv-valve-cmd</input>
2020-05-05 18:43:21 +00:00
<rate_limit > /systems/pneumatics/valves/engine-2-prv-valve-power</rate_limit>
2020-05-05 18:12:14 +00:00
</actuator>
<!-- Overpressure valve -->
<fcs_function name= "/systems/pneumatics/valves/engine-1-opv-valve-cmd-schedule" >
<function >
<table >
2020-05-10 14:11:52 +00:00
<independentVar lookup= "row" > /systems/pneumatics/psi/engine-1-downstream-prv</independentVar>
2020-05-05 18:12:14 +00:00
<tableData >
79 1.0
85 0.0
</tableData>
</table>
</function>
</fcs_function>
<switch name= "/systems/pneumatics/valves/engine-1-opv-valve-cmd" >
<default value= "1" />
<test logic= "AND" value= "0" >
/systems/pneumatics/valves/engine-1-opv-valve-cmd eq 0.0
2020-05-10 14:11:52 +00:00
/systems/pneumatics/psi/engine-1-downstream-prv ge 35
2020-05-05 18:12:14 +00:00
</test>
<test logic= "OR" value= "/systems/pneumatics/valves/engine-1-opv-valve-cmd-schedule" >
/systems/pneumatics/valves/engine-1-opv-valve-cmd-schedule ne 0
</test>
</switch>
<actuator name= "/systems/pneumatics/valves/engine-1-opv-valve" >
<input > /systems/pneumatics/valves/engine-1-opv-valve-cmd</input>
<rate_limit > 1.0</rate_limit> <!-- pneumatically controlled -->
</actuator>
<fcs_function name= "/systems/pneumatics/valves/engine-2-opv-valve-cmd-schedule" >
<function >
<table >
2020-05-10 14:11:52 +00:00
<independentVar lookup= "row" > /systems/pneumatics/psi/engine-2-downstream-prv</independentVar>
2020-05-05 18:12:14 +00:00
<tableData >
79 1.0
85 0.0
</tableData>
</table>
</function>
</fcs_function>
<switch name= "/systems/pneumatics/valves/engine-2-opv-valve-cmd" >
<default value= "1" />
<test logic= "AND" value= "0" >
/systems/pneumatics/valves/engine-2-opv-valve-cmd eq 0.0
2020-05-10 14:11:52 +00:00
/systems/pneumatics/psi/engine-2-downstream-prv ge 35
2020-05-05 18:12:14 +00:00
</test>
<test logic= "OR" value= "/systems/pneumatics/valves/engine-2-opv-valve-cmd-schedule" >
/systems/pneumatics/valves/engine-2-opv-valve-cmd-schedule ne 0
</test>
</switch>
<actuator name= "/systems/pneumatics/valves/engine-2-opv-valve" >
<input > /systems/pneumatics/valves/engine-2-opv-valve-cmd</input>
<rate_limit > 1.0</rate_limit> <!-- pneumatically controlled -->
</actuator>
2020-05-11 14:57:23 +00:00
<!-- Wing Anti Ice -->
<switch name= "/systems/pneumatics/valves/wing-ice-gnd-cmd" >
<default value= "0" />
<test logic= "AND" value= "1" >
/gear/gear[1]/wow eq 1
/controls/ice-protection/wing eq 1
</test>
</switch>
<actuator name= "/systems/pneumatics/valves/wing-ice-gnd" >
<input > /systems/pneumatics/valves/wing-ice-gnd-cmd</input>
<rate_limit sense= "incr" > 0.033333</rate_limit> <!-- 30 seconds -->
2020-10-20 21:24:29 +00:00
<rate_limit sense= "decr" > 120</rate_limit>
2020-05-11 14:57:23 +00:00
</actuator>
<switch name= "/systems/pneumatics/valves/wing-ice-1-cmd" >
<default value= "0" />
2020-05-12 15:57:45 +00:00
<test logic= "AND" value= "0" >
/systems/pneumatics/valves/wing-ice-gnd eq 1
/gear/gear[1]/wow eq 1
/controls/ice-protection/wing eq 1
</test>
2020-05-12 12:47:49 +00:00
<test logic= "OR" value= "0" >
2020-05-11 14:57:23 +00:00
/systems/electrical/bus/dc-ess-shed lt 25
2020-05-12 15:57:45 +00:00
/systems/pneumatics/psi/engine-1-psi le 1
2020-05-11 14:57:23 +00:00
</test>
<test logic= "AND" value= "1" >
/controls/ice-protection/wing eq 1
</test>
</switch>
<switch name= "/systems/pneumatics/valves/wing-ice-1-power" >
<default value= "0" />
2021-12-31 15:03:43 +00:00
<test logic= "AND" value= "10" >
2020-05-26 20:33:26 +00:00
/systems/startup-power-valves eq 1
</test>
2020-05-11 14:57:23 +00:00
<test logic= "OR" value= "0" >
/systems/failures/icing/wing-left-valve eq 1
</test>
2021-12-31 15:03:43 +00:00
<test logic= "AND" value= "0.333" >
2020-05-12 12:47:49 +00:00
<test logic= "OR" >
/systems/electrical/bus/dc-ess-shed lt 25
2020-05-12 15:57:45 +00:00
/systems/pneumatics/psi/engine-1-psi le 1
2020-05-12 12:47:49 +00:00
</test>
2020-05-11 14:57:23 +00:00
/systems/pneumatics/valves/wing-ice-1-cmd eq 0
/systems/pneumatics/valves/wing-ice-1 ne 0
</test>
2021-12-31 15:03:43 +00:00
<test logic= "AND" value= "0.333" >
2020-05-11 14:57:23 +00:00
/systems/electrical/bus/dc-ess-shed ge 25
</test>
</switch>
<actuator name= "/systems/pneumatics/valves/wing-ice-1" >
<input > /systems/pneumatics/valves/wing-ice-1-cmd</input>
<rate_limit > /systems/pneumatics/valves/wing-ice-1-power</rate_limit>
</actuator>
<switch name= "/systems/pneumatics/valves/wing-ice-2-cmd" >
<default value= "0" />
2020-05-12 15:57:45 +00:00
<test logic= "AND" value= "0" >
/systems/pneumatics/valves/wing-ice-gnd eq 1
/gear/gear[1]/wow eq 1
/controls/ice-protection/wing eq 1
</test>
2020-05-12 12:47:49 +00:00
<test logic= "OR" value= "0" >
2020-05-11 14:57:23 +00:00
/systems/electrical/bus/dc-ess-shed lt 25
2020-05-12 15:57:45 +00:00
/systems/pneumatics/psi/engine-2-psi le 1
2020-05-11 14:57:23 +00:00
</test>
<test logic= "AND" value= "1" >
/controls/ice-protection/wing eq 1
</test>
</switch>
<switch name= "/systems/pneumatics/valves/wing-ice-2-power" >
<default value= "0" />
2021-12-31 15:03:43 +00:00
<test logic= "AND" value= "10" >
2020-05-26 20:33:26 +00:00
/systems/startup-power-valves eq 1
</test>
2020-05-11 14:57:23 +00:00
<test logic= "OR" value= "0" >
/systems/failures/icing/wing-right-valve eq 1
</test>
2021-12-31 15:03:43 +00:00
<test logic= "AND" value= "0.333" >
2020-05-12 12:47:49 +00:00
<test logic= "OR" >
/systems/electrical/bus/dc-ess-shed lt 25
2020-05-12 15:57:45 +00:00
/systems/pneumatics/psi/engine-2-psi le 1
2020-05-12 12:47:49 +00:00
</test>
2020-05-11 14:57:23 +00:00
/systems/pneumatics/valves/wing-ice-2-cmd eq 0
/systems/pneumatics/valves/wing-ice-2 ne 0
</test>
2021-12-31 15:03:43 +00:00
<test logic= "AND" value= "0.333" >
2020-05-11 14:57:23 +00:00
/systems/electrical/bus/dc-ess-shed ge 25
</test>
</switch>
<actuator name= "/systems/pneumatics/valves/wing-ice-2" >
<input > /systems/pneumatics/valves/wing-ice-2-cmd</input>
<rate_limit > /systems/pneumatics/valves/wing-ice-2-power</rate_limit>
</actuator>
<switch name= "/systems/pneumatics/valves/engine-ice-1-cmd" >
<default value= "0" />
2020-05-12 12:47:49 +00:00
<test logic= "AND" value= "0" >
/systems/pneumatics/source/engine-1-hp-psi lt 7
</test>
2020-05-11 14:57:23 +00:00
<test logic= "AND" value= "1" >
/systems/electrical/bus/dc-1 lt 25
</test>
<test logic= "AND" value= "1" >
/controls/ice-protection/leng eq 1
</test>
</switch>
<switch name= "/systems/pneumatics/valves/engine-ice-1-power" >
<default value= "0" />
2021-12-31 15:03:43 +00:00
<test logic= "AND" value= "10" >
2020-05-26 20:33:26 +00:00
/systems/startup-power-valves eq 1
</test>
2020-05-12 12:47:49 +00:00
<test logic= "OR" value= "0" >
2020-05-11 14:57:23 +00:00
/systems/failures/icing/engine-left-valve eq 1
</test>
2021-12-31 15:03:43 +00:00
<test logic= "AND" value= "0.5" >
2020-05-12 12:47:49 +00:00
<test logic= "OR" >
/systems/electrical/bus/dc-1 lt 25
/systems/pneumatics/source/engine-1-hp-psi lt 7
</test>
2020-05-11 14:57:23 +00:00
/systems/pneumatics/valves/engine-ice-1-cmd eq 1
/systems/pneumatics/valves/engine-ice-1 ne 1
</test>
2021-12-31 15:03:43 +00:00
<test logic= "AND" value= "0.5" >
2020-05-11 14:57:23 +00:00
/systems/electrical/bus/dc-1 ge 25
</test>
</switch>
<actuator name= "/systems/pneumatics/valves/engine-ice-1" >
<input > /systems/pneumatics/valves/engine-ice-1-cmd</input>
<rate_limit > /systems/pneumatics/valves/engine-ice-1-power</rate_limit>
</actuator>
<switch name= "/systems/pneumatics/valves/engine-ice-2-cmd" >
<default value= "0" />
2020-05-12 12:47:49 +00:00
<test logic= "AND" value= "0" >
/systems/pneumatics/source/engine-2-hp-psi lt 7
</test>
2020-05-11 14:57:23 +00:00
<test logic= "AND" value= "1" >
/systems/electrical/bus/dc-2 lt 25
</test>
<test logic= "AND" value= "1" >
/controls/ice-protection/reng eq 1
</test>
</switch>
<switch name= "/systems/pneumatics/valves/engine-ice-2-power" >
<default value= "0" />
2021-12-31 15:03:43 +00:00
<test logic= "AND" value= "10" >
2020-05-26 20:33:26 +00:00
/systems/startup-power-valves eq 1
</test>
2020-05-12 12:47:49 +00:00
<test logic= "OR" value= "0" >
2020-05-11 14:57:23 +00:00
/systems/failures/icing/engine-right-valve eq 1
</test>
2021-12-31 15:03:43 +00:00
<test logic= "AND" value= "0.5" >
2020-05-12 12:47:49 +00:00
<test logic= "OR" >
/systems/electrical/bus/dc-2 lt 25
/systems/pneumatics/source/engine-2-hp-psi lt 7
</test>
2020-05-11 14:57:23 +00:00
/systems/pneumatics/valves/engine-ice-2-cmd eq 1
/systems/pneumatics/valves/engine-ice-2 ne 1
</test>
2021-12-31 15:03:43 +00:00
<test logic= "AND" value= "0.5" >
2020-05-11 14:57:23 +00:00
/systems/electrical/bus/dc-2 ge 25
</test>
</switch>
<actuator name= "/systems/pneumatics/valves/engine-ice-2" >
<input > /systems/pneumatics/valves/engine-ice-2-cmd</input>
<rate_limit > /systems/pneumatics/valves/engine-ice-2-power</rate_limit>
</actuator>
2020-05-05 18:12:14 +00:00
</channel>
2020-07-19 13:01:13 +00:00
<channel name= "Source PSI" execrate= "8" >
2020-05-05 18:12:14 +00:00
2020-05-05 20:58:50 +00:00
<fcs_function name= "/systems/pneumatics/source/apu-psi" >
<function >
<ifthen >
<gt >
<property > /position/altitude-ft</property>
<value > 20000</value>
</gt>
<value > 0</value>
<ifthen >
<gt >
<property > /engines/engine[2]/n1</property>
<value > 92</value>
</gt>
<difference >
<interpolate1d >
<property > /position/altitude-ft</property>
<value > 0</value>
<table >
<independentVar lookup= "row" > /engines/engine[2]/n1</independentVar>
<independentVar lookup= "column" > /systems/pneumatics/valves/apu-bleed-valve</independentVar>
<tableData >
0 1
92 0 0
95 16.7 2.7
100 58.7 50.7
</tableData>
</table>
<value > 10000</value>
<table >
<independentVar lookup= "row" > /engines/engine[2]/n1</independentVar>
<independentVar lookup= "column" > /systems/pneumatics/valves/apu-bleed-valve</independentVar>
<tableData >
0 1
92 0 0
95 6.7 0.1
100 48.7 40.7
</tableData>
</table>
<value > 15000</value>
<table >
<independentVar lookup= "row" > /engines/engine[2]/n1</independentVar>
<independentVar lookup= "column" > /systems/pneumatics/valves/apu-bleed-valve</independentVar>
<tableData >
0 1
92 0 0
95 2.7 0
100 37.7 32.7
</tableData>
</table>
</interpolate1d>
<quotient >
<property > /systems/navigation/probes/static-1</property>
<value > 2.036</value>
</quotient>
</difference>
<value > 0</value>
</ifthen>
</ifthen>
</function>
<clipto >
<min > 0</min>
<max > 99999999</max>
</clipto>
</fcs_function>
<fcs_function name= "/systems/pneumatics/source/gnd-psi" >
<function >
<product >
2021-11-02 21:32:24 +00:00
<property > /controls/pneumatics/switches/ground-air</property>
2020-05-05 20:58:50 +00:00
<value > 34</value>
</product>
</function>
</fcs_function>
2020-05-05 18:12:14 +00:00
<fcs_function name= "/systems/pneumatics/source/engine-1-hp-psi" >
<function >
<table >
<independentVar lookup= "row" > /engines/engine[0]/n2-actual</independentVar>
<tableData >
22.0 0.0
25.0 12.0
44.0 22.0
60.9 72.0
65.0 78.0
70.4 96.0
80.4 132.0
</tableData>
</table>
</function>
</fcs_function>
<fcs_function name= "/systems/pneumatics/source/engine-2-hp-psi" >
<function >
<table >
<independentVar lookup= "row" > /engines/engine[1]/n2-actual</independentVar>
<tableData >
22.0 0.0
25.0 12.0
44.0 22.0
60.9 72.0
65.0 78.0
70.4 96.0
80.4 132.0
</tableData>
</table>
</function>
</fcs_function>
<fcs_function name= "/systems/pneumatics/source/engine-1-lp-psi" >
<function >
<table >
<independentVar lookup= "row" > /engines/engine[0]/n2-actual</independentVar>
<tableData >
22.0 0.0
25.0 2.0
60.9 18.0
70.4 36.0
80.4 44.0
101.4 48.0
</tableData>
</table>
</function>
</fcs_function>
<fcs_function name= "/systems/pneumatics/source/engine-2-lp-psi" >
<function >
<table >
<independentVar lookup= "row" > /engines/engine[1]/n2-actual</independentVar>
<tableData >
22.0 0.0
25.0 2.0
60.9 18.0
70.4 36.0
80.4 44.0
101.4 48.0
</tableData>
</table>
</function>
</fcs_function>
2021-05-16 18:05:12 +00:00
2020-05-05 18:12:14 +00:00
</channel>
2020-07-19 13:01:13 +00:00
<channel name= "System PSI" execrate= "8" >
2020-09-12 16:57:23 +00:00
2020-05-05 18:12:14 +00:00
<fcs_function name= "/systems/pneumatics/psi/engine-1-upstream-src" >
<function >
<ifthen >
<lt >
<property > /systems/pneumatics/valves/engine-1-hp-valve</property> <!-- lp valve opens when the airflow reduces sufficiently from hp valve -->
<value > 0.1</value>
</lt>
<product >
<property > /systems/pneumatics/source/engine-1-lp-psi</property>
<property > /systems/pneumatics/valves/engine-1-lp-valve</property>
</product>
<product >
<quotient >
<property > /systems/pneumatics/source/engine-1-hp-psi</property>
<value > 3</value>
</quotient>
<property > /systems/pneumatics/valves/engine-1-hp-valve</property>
</product>
</ifthen>
</function>
</fcs_function>
<fcs_function name= "/systems/pneumatics/psi/engine-2-upstream-src" >
<function >
<ifthen >
<lt >
2020-05-10 22:58:26 +00:00
<property > /systems/pneumatics/valves/engine-2-hp-valve</property>
2020-05-05 18:12:14 +00:00
<value > 0.1</value>
</lt>
<product >
<property > /systems/pneumatics/source/engine-2-lp-psi</property>
<property > /systems/pneumatics/valves/engine-2-lp-valve</property>
</product>
<product >
<quotient >
<property > /systems/pneumatics/source/engine-2-hp-psi</property>
<value > 3</value>
</quotient>
<property > /systems/pneumatics/valves/engine-2-hp-valve</property>
</product>
</ifthen>
</function>
</fcs_function>
2020-05-05 20:58:50 +00:00
<fcs_function name= "/systems/pneumatics/psi/engine-1-downstream-prv" >
2020-05-05 18:12:14 +00:00
<function >
<product >
<property > /systems/pneumatics/valves/engine-1-prv-valve</property>
<property > /systems/pneumatics/psi/engine-1-upstream-src</property>
</product>
</function>
</fcs_function>
2020-05-05 20:58:50 +00:00
<fcs_function name= "/systems/pneumatics/psi/engine-2-downstream-prv" >
2020-05-05 18:12:14 +00:00
<function >
<product >
<property > /systems/pneumatics/valves/engine-2-prv-valve</property>
<property > /systems/pneumatics/psi/engine-2-upstream-src</property>
</product>
</function>
</fcs_function>
2020-05-10 14:11:52 +00:00
<fcs_function name= "/systems/pneumatics/psi/engine-1-downstream-opv" >
<function >
<product >
<property > /systems/pneumatics/valves/engine-1-opv-valve</property>
<property > /systems/pneumatics/psi/engine-1-downstream-prv</property>
</product>
</function>
</fcs_function>
<fcs_function name= "/systems/pneumatics/psi/engine-2-downstream-opv" >
<function >
<product >
<property > /systems/pneumatics/valves/engine-2-opv-valve</property>
<property > /systems/pneumatics/psi/engine-2-downstream-prv</property>
</product>
</function>
</fcs_function>
2020-05-26 20:33:26 +00:00
<switch name= "/systems/pneumatics/psi/engine-left-src" >
<default value= "/systems/pneumatics/psi/engine-left-src" />
<test logic= "AND" value= "1" > <!-- apu -->
2020-05-07 16:19:05 +00:00
/systems/pneumatics/source/apu-psi ne 0
2020-06-16 17:51:43 +00:00
/systems/pneumatics/valves/apu-bleed-valve ge 0.5
2020-05-07 16:19:05 +00:00
</test>
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "2" > <!-- left engine -->
<test logic= "OR" >
/systems/pneumatics/psi/engine-1-downstream-opv ge /systems/pneumatics/psi/engine-2-psi
2020-05-11 16:54:54 +00:00
/systems/pneumatics/valves/crossbleed-valve eq 0
</test>
2020-05-26 20:33:26 +00:00
/systems/pneumatics/valves/engine-1-prv-valve ne 0
/systems/pneumatics/valves/engine-1-opv-valve ne 0
2020-05-07 16:19:05 +00:00
</test>
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "3" > <!-- left engine -->
/systems/pneumatics/psi/engine-1-downstream-opv lt /systems/pneumatics/psi/engine-2-psi
2020-05-07 16:19:05 +00:00
/systems/pneumatics/valves/crossbleed-valve ne 0
2020-05-26 20:33:26 +00:00
/systems/pneumatics/psi/engine-right-src ne 3
2020-05-07 16:19:05 +00:00
</test>
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "4" > <!-- gnd has lowest priority, valve forced closed if other source available -->
2020-05-11 12:08:55 +00:00
/systems/pneumatics/source/gnd-psi ne 0
</test>
2020-06-15 17:49:42 +00:00
<test logic= "AND" value= "0" > <!-- manually cancel -->
/systems/pneumatics/source/apu-psi ne 0
/systems/pneumatics/valves/apu-bleed-valve eq 0
</test>
2020-05-07 16:19:05 +00:00
</switch>
2020-05-26 20:33:26 +00:00
<switch name= "/systems/pneumatics/psi/engine-right-src" >
<default value= "/systems/pneumatics/psi/engine-right-src" />
<test logic= "AND" value= "1" > <!-- apu -->
2020-05-07 16:19:05 +00:00
/systems/pneumatics/source/apu-psi ne 0
2020-06-16 17:51:43 +00:00
/systems/pneumatics/valves/apu-bleed-valve ge 0.5
2020-05-26 20:33:26 +00:00
/systems/pneumatics/valves/crossbleed-valve ne 0
2020-05-07 16:19:05 +00:00
</test>
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "2" > <!-- right engine -->
<test logic= "OR" >
/systems/pneumatics/psi/engine-2-downstream-opv ge /systems/pneumatics/psi/engine-1-psi
2020-05-11 16:54:54 +00:00
/systems/pneumatics/valves/crossbleed-valve eq 0
</test>
2020-05-26 20:33:26 +00:00
/systems/pneumatics/valves/engine-2-prv-valve ne 0
/systems/pneumatics/valves/engine-2-opv-valve ne 0
2020-05-07 16:19:05 +00:00
</test>
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "3" > <!-- left engine -->
/systems/pneumatics/psi/engine-2-downstream-opv lt /systems/pneumatics/psi/engine-1-psi
2020-05-07 16:19:05 +00:00
/systems/pneumatics/valves/crossbleed-valve ne 0
2020-05-26 20:33:26 +00:00
/systems/pneumatics/psi/engine-left-src ne 3
2020-05-07 16:19:05 +00:00
</test>
2020-05-26 20:33:26 +00:00
<test logic= "AND" value= "4" > <!-- gnd has lowest priority, valve forced closed if other source available -->
2020-05-11 12:08:55 +00:00
/systems/pneumatics/source/gnd-psi ne 0
2020-05-26 20:33:26 +00:00
/systems/pneumatics/valves/crossbleed-valve ne 0
2020-05-11 12:08:55 +00:00
</test>
2020-06-15 17:49:42 +00:00
<test logic= "AND" value= "0" > <!-- manually cancel -->
/systems/pneumatics/source/apu-psi ne 0
/systems/pneumatics/valves/crossbleed-valve eq 0
</test>
2020-05-07 16:19:05 +00:00
</switch>
2020-06-16 17:51:43 +00:00
<fcs_function name= "/systems/pneumatics/psi/engine-1-psi" >
<function >
<switch >
<p > /systems/pneumatics/psi/engine-left-src</p>
<v > 0</v>
<product >
<property > /systems/pneumatics/valves/apu-bleed-valve</property>
<property > /systems/pneumatics/source/apu-psi</property>
</product>
<property > /systems/pneumatics/psi/engine-1-downstream-opv</property>
<property > /systems/pneumatics/psi/engine-2-psi</property>
<property > /systems/pneumatics/source/gnd-psi</property>
</switch>
</function>
</fcs_function>
<fcs_function name= "/systems/pneumatics/psi/engine-2-psi" >
<function >
<switch >
<p > /systems/pneumatics/psi/engine-right-src</p>
<v > 0</v>
<product >
<property > /systems/pneumatics/valves/apu-bleed-valve</property>
<property > /systems/pneumatics/valves/crossbleed-valve</property>
<property > /systems/pneumatics/source/apu-psi</property>
</product>
<property > /systems/pneumatics/psi/engine-2-downstream-opv</property>
<property > /systems/pneumatics/psi/engine-1-psi</property>
<property > /systems/pneumatics/source/gnd-psi</property>
</switch>
</function>
</fcs_function>
2020-05-05 18:12:14 +00:00
2020-05-05 20:58:50 +00:00
</channel>
2020-07-19 13:01:13 +00:00
<channel name= "Precooler Left" execute= "/systems/pneumatics/indicating/bmc1-working" execrate= "8" > <!-- These values come from BMC, so makes sense to not have them when BMC lacks power -->
2020-05-05 20:58:50 +00:00
2020-05-11 12:08:55 +00:00
<fcs_function name= "/systems/pneumatics/precooler/calc/temp-1" >
2020-05-05 20:58:50 +00:00
<function >
<sum >
2020-05-10 22:58:26 +00:00
<value > 15</value>
2020-05-10 15:35:20 +00:00
<ifthen >
<nq >
<product >
<property > /systems/pneumatics/valves/engine-1-prv-valve</property>
<property > /systems/pneumatics/valves/engine-1-opv-valve</property>
</product>
<value > 0</value>
</nq>
<product >
<property > /engines/engine[0]/egt-actual</property>
2020-05-11 12:08:55 +00:00
<property > /systems/pneumatics/egt-1-factor</property>
2020-05-10 15:35:20 +00:00
</product>
<product >
<property > /systems/pneumatics/valves/apu-bleed-valve</property>
<property > /systems/apu/egt-degC</property>
<value > 0.40</value>
</product>
</ifthen>
2020-05-05 20:58:50 +00:00
</sum>
</function>
</fcs_function>
2020-05-11 12:08:55 +00:00
<lag_filter name= "/systems/pneumatics/precooler/temp-1" >
<input > /systems/pneumatics/precooler/calc/temp-1</input>
<c1 > 0.8</c1>
</lag_filter>
2020-05-05 18:12:14 +00:00
<switch name= "/systems/pneumatics/precooler/calc/ovht-5-true" >
<default value= "0" />
<test value= "1" >
/systems/pneumatics/precooler/temp-1 gt 290
</test>
</switch>
<switch name= "/systems/pneumatics/precooler/calc/ovht-15-true" >
<default value= "0" />
<test value= "1" >
/systems/pneumatics/precooler/temp-1 gt 270
</test>
</switch>
<switch name= "/systems/pneumatics/precooler/calc/ovht-55-true" >
<default value= "0" />
<test value= "1" >
/systems/pneumatics/precooler/temp-1 gt 257
</test>
</switch>
<actuator name= "/systems/pneumatics/precooler/calc/ovht-5" >
<input > /systems/pneumatics/precooler/calc/ovht-5-true</input>
<rate_limit sense= "incr" > 0.2</rate_limit>
2020-10-20 21:24:29 +00:00
<rate_limit sense= "decr" > 120</rate_limit>
2020-05-05 18:12:14 +00:00
</actuator>
<actuator name= "/systems/pneumatics/precooler/calc/ovht-15" >
<input > /systems/pneumatics/precooler/calc/ovht-15-true</input>
<rate_limit sense= "incr" > 0.06666</rate_limit>
2020-10-20 21:24:29 +00:00
<rate_limit sense= "decr" > 120</rate_limit>
2020-05-05 18:12:14 +00:00
</actuator>
<actuator name= "/systems/pneumatics/precooler/calc/ovht-55" >
<input > /systems/pneumatics/precooler/calc/ovht-55-true</input>
<rate_limit sense= "incr" > 0.018182</rate_limit>
2020-10-20 21:24:29 +00:00
<rate_limit sense= "decr" > 120</rate_limit>
2020-05-05 18:12:14 +00:00
</actuator>
2020-05-05 20:58:50 +00:00
<switch name= "/systems/pneumatics/precooler/ovht-1" >
<default value= "0" />
<test logic= "OR" value= "1" >
/systems/pneumatics/precooler/calc/ovht-5 eq 1
/systems/pneumatics/precooler/calc/ovht-15 eq 1
/systems/pneumatics/precooler/calc/ovht-55 eq 1
</test>
</switch>
2020-05-11 12:08:55 +00:00
<switch name= "/systems/pneumatics/warnings/ovht-1-mem" >
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/pneumatics/warnings/ovht-1-mem eq 1
/controls/pneumatics/switches/bleed-1 eq 1
</test>
<test logic= "AND" value= "1" >
/systems/pneumatics/precooler/ovht-1 eq 1
</test>
</switch>
2020-05-10 22:58:26 +00:00
<switch name= "/systems/pneumatics/warnings/lowtemp-1" >
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/pneumatics/precooler/temp-1 lt 150
2020-05-11 14:57:23 +00:00
/systems/pneumatics/valves/wing-ice-1 eq 1
2020-05-10 22:58:26 +00:00
/gear/gear[1]/wow eq 0
</test>
</switch>
2020-05-11 12:45:00 +00:00
<switch name= "/systems/pneumatics/warnings/lowtemp-1-mem" >
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/pneumatics/warnings/lowtemp-1-mem eq 1
/controls/pneumatics/switches/bleed-1 eq 1
</test>
<test logic= "AND" value= "1" >
/systems/pneumatics/warnings/lowtemp-1 eq 1
</test>
</switch>
2020-05-05 20:58:50 +00:00
</channel>
2020-07-19 13:01:13 +00:00
<channel name= "Precooler Right" execute= "/systems/pneumatics/indicating/bmc2-working" execrate= "8" > <!-- These values come from BMC, so makes sense to not have them when BMC lacks power -->
2020-05-05 20:58:50 +00:00
2020-05-11 12:08:55 +00:00
<fcs_function name= "/systems/pneumatics/precooler/calc/temp-2" >
2020-05-05 20:58:50 +00:00
<function >
<sum >
2020-05-11 12:08:55 +00:00
<value > 15</value>
2020-05-10 15:35:20 +00:00
<ifthen >
<nq >
<product >
<property > /systems/pneumatics/valves/engine-2-prv-valve</property>
<property > /systems/pneumatics/valves/engine-2-opv-valve</property>
</product>
<value > 0</value>
</nq>
<product >
<property > /engines/engine[1]/egt-actual</property>
2020-05-11 12:08:55 +00:00
<property > /systems/pneumatics/egt-2-factor</property>
2020-05-10 15:35:20 +00:00
</product>
<product >
<property > /systems/pneumatics/valves/apu-bleed-valve</property>
<property > /systems/apu/egt-degC</property>
<value > 0.40</value>
</product>
</ifthen>
2020-05-05 20:58:50 +00:00
</sum>
</function>
</fcs_function>
2020-05-05 18:12:14 +00:00
2020-05-11 12:08:55 +00:00
<lag_filter name= "/systems/pneumatics/precooler/temp-2" >
<input > /systems/pneumatics/precooler/calc/temp-2</input>
<c1 > 0.8</c1>
</lag_filter>
2020-05-05 18:12:14 +00:00
<switch name= "/systems/pneumatics/precooler/calc/ovht-5-true-2" >
<default value= "0" />
<test value= "1" >
/systems/pneumatics/precooler/temp-2 gt 290
</test>
</switch>
<switch name= "/systems/pneumatics/precooler/calc/ovht-15-true-2" >
<default value= "0" />
<test value= "1" >
/systems/pneumatics/precooler/temp-2 gt 270
</test>
</switch>
<switch name= "/systems/pneumatics/precooler/calc/ovht-55-true-2" >
<default value= "0" />
<test value= "1" >
/systems/pneumatics/precooler/temp-2 gt 257
</test>
</switch>
<actuator name= "/systems/pneumatics/precooler/calc/ovht-5-2" >
<input > /systems/pneumatics/precooler/calc/ovht-5-true-2</input>
<rate_limit sense= "incr" > 0.2</rate_limit>
2020-10-20 21:24:29 +00:00
<rate_limit sense= "decr" > 120</rate_limit>
2020-05-05 18:12:14 +00:00
</actuator>
<actuator name= "/systems/pneumatics/precooler/calc/ovht-15-2" >
<input > /systems/pneumatics/precooler/calc/ovht-15-true-2</input>
<rate_limit sense= "incr" > 0.06666</rate_limit>
2020-10-20 21:24:29 +00:00
<rate_limit sense= "decr" > 120</rate_limit>
2020-05-05 18:12:14 +00:00
</actuator>
<actuator name= "/systems/pneumatics/precooler/calc/ovht-55-2" >
<input > /systems/pneumatics/precooler/calc/ovht-55-true-2</input>
<rate_limit sense= "incr" > 0.018182</rate_limit>
2020-10-20 21:24:29 +00:00
<rate_limit sense= "decr" > 120</rate_limit>
2020-05-05 18:12:14 +00:00
</actuator>
2020-05-05 20:58:50 +00:00
2020-05-05 18:12:14 +00:00
<switch name= "/systems/pneumatics/precooler/ovht-2" >
<default value= "0" />
<test logic= "OR" value= "1" >
/systems/pneumatics/precooler/calc/ovht-5-2 eq 1
/systems/pneumatics/precooler/calc/ovht-15-2 eq 1
/systems/pneumatics/precooler/calc/ovht-55-2 eq 1
</test>
</switch>
2020-05-10 22:58:26 +00:00
2020-05-11 12:08:55 +00:00
<switch name= "/systems/pneumatics/warnings/ovht-2-mem" >
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/pneumatics/warnings/ovht-2-mem eq 1
/controls/pneumatics/switches/bleed-2 eq 1
</test>
<test logic= "AND" value= "1" >
/systems/pneumatics/precooler/ovht-2 eq 1
</test>
</switch>
2020-05-10 22:58:26 +00:00
<switch name= "/systems/pneumatics/warnings/lowtemp-2" >
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/pneumatics/precooler/temp-2 lt 150
2020-05-11 14:57:23 +00:00
/systems/pneumatics/valves/wing-ice-2 eq 1
2020-05-10 22:58:26 +00:00
/gear/gear[1]/wow eq 0
</test>
</switch>
2020-05-11 12:45:00 +00:00
<switch name= "/systems/pneumatics/warnings/lowtemp-2-mem" >
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/pneumatics/warnings/lowtemp-2-mem eq 1
/controls/pneumatics/switches/bleed-2 eq 1
</test>
<test logic= "AND" value= "1" >
/systems/pneumatics/warnings/lowtemp-2 eq 1
</test>
</switch>
2020-05-05 18:12:14 +00:00
</channel>
2020-07-19 13:01:13 +00:00
<channel name= "ECAM" execrate= "8" >
2020-05-05 20:58:50 +00:00
<switch name= "/systems/pneumatics/indicating/bmc1-working" >
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/electrical/bus/dc-ess-shed ge 25
/systems/failures/pneumatics/bmc-1 ne 1
</test>
</switch>
<switch name= "/systems/pneumatics/indicating/bmc2-working" >
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/electrical/bus/dc-2 ge 25
/systems/failures/pneumatics/bmc-2 ne 1
</test>
</switch>
2020-05-05 18:43:21 +00:00
<switch name= "/systems/pneumatics/warnings/apu-bleed-not-on-cmd" >
<default value= "0" />
<test logic= "AND" value= "1" >
2020-06-16 17:51:43 +00:00
/systems/pneumatics/valves/apu-bleed-valve ne 1
2020-05-05 18:43:21 +00:00
/controls/apu/master eq 1
/controls/pneumatics/switches/apu eq 1
</test>
</switch>
<actuator name= "/systems/pneumatics/warnings/apu-bleed-not-on" >
<input > /systems/pneumatics/warnings/apu-bleed-not-on-cmd</input>
<rate_limit sense= "incr" > 0.1</rate_limit>
2020-10-20 21:24:29 +00:00
<rate_limit sense= "decr" > 120</rate_limit>
2020-05-05 18:43:21 +00:00
</actuator>
2021-01-29 21:09:21 +00:00
<switch name= "/systems/pneumatics/warnings/crossbleed-disag-open-man" >
2020-05-06 20:34:08 +00:00
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/pneumatics/valves/crossbleed-valve-cmd eq 1
/systems/pneumatics/valves/crossbleed-valve ne 1
/controls/pneumatics/switches/x-bleed eq 2
</test>
2021-01-29 21:09:21 +00:00
</switch>
<switch name= "/systems/pneumatics/warnings/crossbleed-disag-open-auto" >
<default value= "0" />
2020-05-06 20:34:08 +00:00
<test logic= "AND" value= "1" >
/systems/pneumatics/valves/crossbleed-valve-cmd eq 1
/systems/pneumatics/valves/crossbleed-valve ne 1
/controls/pneumatics/switches/x-bleed eq 1
</test>
</switch>
2021-01-29 21:09:21 +00:00
<switch name= "/systems/pneumatics/warnings/crossbleed-disag-open" >
<default value= "0" />
<test logic= "OR" value= "1" >
/systems/pneumatics/warnings/crossbleed-disag-open-man eq 1
<test logic= "AND" >
/systems/pneumatics/warnings/crossbleed-disag-open-auto eq 1
/systems/electrical/bus/dc-2 ge 25
</test>
</test>
</switch>
<switch name= "/systems/pneumatics/warnings/crossbleed-disag-closed" >
2020-05-06 20:34:08 +00:00
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/pneumatics/valves/crossbleed-valve-cmd eq 0
/systems/pneumatics/valves/crossbleed-valve ne 0
</test>
2021-01-29 21:09:21 +00:00
</switch>
<switch name= "/systems/pneumatics/warnings/crossbleed-disag" >
<default value= "0" />
<test logic= "OR" value= "1" >
/systems/pneumatics/warnings/crossbleed-disag-closed eq 1
2020-05-06 20:34:08 +00:00
/systems/pneumatics/warnings/crossbleed-disag-open eq 1
</test>
</switch>
2020-05-10 22:58:26 +00:00
<switch name= "/systems/pneumatics/warnings/bleed1-fault" >
<default value= "0" />
2020-05-22 20:43:31 +00:00
<test logic= "AND" value= "0" >
/systems/acconfig/autoconfig-running eq 1
</test>
2020-05-10 22:58:26 +00:00
<test logic= "AND" value= "0" >
/systems/pneumatics/warnings/bleed1-fault eq 1
/controls/pneumatics/switches/bleed-1 eq 0
/ECAM/warnings/timer/bleed-1-fault-output eq 0
/ECAM/warnings/timer/prv-1-not-shut-output eq 0
</test>
<test logic= "AND" value= "1" >
/systems/pneumatics/warnings/bleed1-fault eq 1
/controls/pneumatics/switches/bleed-1 eq 1
</test>
<test logic= "OR" value= "1" >
/ECAM/warnings/timer/bleed-1-fault-output eq 1
/ECAM/warnings/timer/prv-1-not-shut-output eq 1
2020-05-11 12:08:55 +00:00
/systems/pneumatics/warnings/ovht-1-mem eq 1
2020-05-10 22:58:26 +00:00
</test>
</switch>
<switch name= "/systems/pneumatics/warnings/bleed2-fault" >
<default value= "0" />
<test logic= "AND" value= "0" >
2020-05-22 20:43:31 +00:00
/systems/acconfig/autoconfig-running eq 1
</test>
<test logic= "AND" value= "0" >
2020-05-10 22:58:26 +00:00
/systems/pneumatics/warnings/bleed2-fault eq 1
/controls/pneumatics/switches/bleed-2 eq 0
/ECAM/warnings/timer/bleed-2-fault-output eq 0
/ECAM/warnings/timer/prv-2-not-shut-output eq 0
</test>
<test logic= "AND" value= "1" >
/systems/pneumatics/warnings/bleed2-fault eq 1
/controls/pneumatics/switches/bleed-2 eq 1
</test>
<test logic= "OR" value= "1" >
/ECAM/warnings/timer/bleed-2-fault-output eq 1
/ECAM/warnings/timer/prv-2-not-shut-output eq 1
2020-05-11 12:08:55 +00:00
/systems/pneumatics/warnings/ovht-2-mem eq 1
</test>
</switch>
<switch name= "/systems/pneumatics/warnings/overpress-1-mem" >
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/pneumatics/warnings/overpress-1-mem eq 1
/controls/pneumatics/switches/bleed-1 eq 1
</test>
<test logic= "AND" value= "1" >
/systems/pneumatics/psi/engine-1-downstream-prv gt 57
</test>
</switch>
<switch name= "/systems/pneumatics/warnings/overpress-2-mem" >
<default value= "0" />
<test logic= "AND" value= "1" >
/systems/pneumatics/warnings/overpress-2-mem eq 1
/controls/pneumatics/switches/bleed-2 eq 1
</test>
<test logic= "AND" value= "1" >
/systems/pneumatics/psi/engine-2-downstream-prv gt 57
2020-05-10 22:58:26 +00:00
</test>
</switch>
2020-05-11 14:57:23 +00:00
<switch name= "/controls/ice-protection/wingfault" >
<default value= "0" />
<test logic= "OR" value= "1" >
2021-12-31 15:03:43 +00:00
/ECAM/warnings/logic/wing-anti-ice-sys-fault eq 1
/ECAM/warnings/flipflop/wing-anti-ice-left-open eq 1
/ECAM/warnings/flipflop/wing-anti-ice-right-open eq 1
/systems/pneumatics/valves/wing-ice-1 ne /systems/pneumatics/valves/wing-ice-1-cmd
/systems/pneumatics/valves/wing-ice-2 ne /systems/pneumatics/valves/wing-ice-2-cmd
2020-05-11 14:57:23 +00:00
/systems/electrical/bus/dc-ess-shed lt 25
</test>
</switch>
<switch name= "/controls/ice-protection/lengfault" >
<default value= "0" />
<test logic= "OR" value= "1" >
2020-05-12 12:47:49 +00:00
/systems/pneumatics/valves/engine-ice-1 ne /controls/ice-protection/leng
2020-05-11 14:57:23 +00:00
</test>
</switch>
<switch name= "/controls/ice-protection/rengfault" >
<default value= "0" />
<test logic= "OR" value= "1" >
2020-05-12 12:47:49 +00:00
/systems/pneumatics/valves/engine-ice-2 ne /controls/ice-protection/reng
2020-05-11 14:57:23 +00:00
</test>
</switch>
2020-07-11 22:17:58 +00:00
<switch name= "/controls/ice-protection/windowprobeheat-output" >
<default value= "0" />
<test logic= "OR" value= "1" >
/controls/ice-protection/windowprobeheat eq 1
<test logic= "OR" >
/systems/electrical/bus/ac-ess ge 110
/systems/electrical/bus/ac-1 ge 110
/systems/electrical/bus/ac-2 ge 110
</test>
</test>
<test logic= "AND" value= "1" >
/controls/ice-protection/windowprobeheat eq 0
/gear/gear[1]/wow eq 1
<test logic= "OR" >
/engines/engine[0]/state eq 3
/engines/engine[1]/state eq 3
</test>
<test logic= "OR" >
/systems/electrical/bus/ac-ess ge 110
/systems/electrical/bus/ac-1 ge 110
/systems/electrical/bus/ac-2 ge 110
</test>
</test>
</switch>
2020-05-05 18:43:21 +00:00
</channel>
2020-05-05 18:12:14 +00:00