Correct behaviour of eng 2 prv when crossbleed + apu bleed open; also fix something else
This commit is contained in:
parent
30d3a5bd6d
commit
780c8b84c4
3 changed files with 8 additions and 5 deletions
|
@ -1214,8 +1214,8 @@
|
|||
<wing-ice-2 type="double">0</wing-ice-2>
|
||||
<pack-1 type="double">0</pack-1>
|
||||
<pack-2 type="double">0</pack-2>
|
||||
<starter-valve-1 type="double">0</starter-valve-1>
|
||||
<starter-valve-2 type="double">0</starter-valve-2>
|
||||
<starter-valve-1 type="bool">0</starter-valve-1>
|
||||
<starter-valve-2 type="bool">0</starter-valve-2>
|
||||
</valves>
|
||||
<warnings>
|
||||
<apu-bleed-not-on-cmd type="bool">0</apu-bleed-not-on-cmd>
|
||||
|
|
|
@ -4282,7 +4282,7 @@
|
|||
<object-name>APUBleedBtn1F</object-name>
|
||||
<condition>
|
||||
<or>
|
||||
<and>
|
||||
<!--<and>
|
||||
<equals>
|
||||
<property>systems/pneumatic/bleedapu-fault</property>
|
||||
<value>1</value>
|
||||
|
@ -4291,7 +4291,7 @@
|
|||
<property>controls/pneumatics/switches/apu</property>
|
||||
<value>1</value>
|
||||
</equals>
|
||||
</and>
|
||||
</and> leak not simulated yet -->
|
||||
<equals>
|
||||
<property>controls/switches/annun-test</property>
|
||||
<value>1</value>
|
||||
|
|
|
@ -292,7 +292,10 @@
|
|||
<test logic="OR" value="0">
|
||||
/controls/engines/engine[1]/fire-btn eq 1
|
||||
/controls/pneumatics/switches/bleed-2 eq 0
|
||||
/systems/pneumatics/valves/apu-bleed-valve ne 0
|
||||
<test logic="AND">
|
||||
/systems/pneumatics/valves/apu-bleed-valve ne 0
|
||||
/systems/pneumatics/valves/crossbleed-valve ne 0
|
||||
</test>
|
||||
/systems/pneumatics/valves/starter-valve-2 ne 0
|
||||
/systems/pneumatics/valves/engine-2-prv-valve-autoclose-cmd eq 1
|
||||
</test>
|
||||
|
|
Loading…