I've added some digital filters to the autopilot. They are all low-pass
filters that filter away high frequency signals/noise. There are 4 different
filters:
1. Exponential - The algorithm is essentially the same as the one used in the
fgGetLowPass() function.
2. Double exponential - Two exponential filters in series. This filter has a
"steeper" frequency response curve. It filters "better" than the single
exponential.
3. Moving average - Averages a number of inputs.
4. Noise spike - limits the amount that the output value can change from one
sample to the next.
Filters 1 and 2 are characterised by it's filter-time in seconds. For filter 3
you have to set the number of input samples to average over. For filter 4 you
set the maximum allowed rate of change as [1/s]. Since the sampling interval
(dt) isn't constant we have to calculate the maximum allowed change for every
update.
Example of a double exponential filter with filter time 0.1 seconds, that is
1/0.1 = 10 Hz.
<filter>
<name>pressure-rate-filter</name>
<debug>true</debug>
<type>double-exponential</type>
<input>/autopilot/internal/pressure-rate</input>
<output>/autopilot/internal/filtered-pressure-rate</output>
<filter-time>0.1</filter-time>
</filter>
This would go in the autopilot configuration file.
I've also removed the filtering of the "pressure-rate" helper value, use the
new filters if you want to filter it! ;-)
This patch adds the ability to do a simple scaling of input without having to
add hardcoded helpers. Example:
<reference>
<prop>/autopilot/settings/vertical-speed-fpm</prop>
<scale>0.01667</scale>
</reference>
Add FGPredictor class to xmlauto. Add support for horizontal navigation based
on flight track as opposed to heading. Add crosstrack-error support to nav.
Simplify error adjust calculation for horizontal nav (better interception).
Fixed potential divide by zero that was producing nan issues in the xmlauto
code.
I've done some changes to xmlauto.cxx.
Only calculate the derivate filtering if derivate time Td is greater than
zero. This means that one can set Td=0.0 in the xml file to completely remove
the derivate action. (Setting Td to zero in the current version would lead to
a division by zero and crash.)
Setting the integrator time Ti to zero doesn't make sense, right! I've
modified so that setting Ti to zero results in the integral action being
completely removed.
seem to be fully deterministic in P-only mode. This old simple controller
does what I expect, so it's good for calulating stage #1's of multi-stage
controllers.