Change from Dave Perry:
I am attaching a trivial patch that changes the normalization from 24 to 12 in turn_indicator.cxx. With this change, the pa24 tc has a turn indicator spin value in the property tree of 0.9996 and the same value for the pa28-161 is 1.0, so there is no harm to a 24 volt electrical system in this change. Should the battery or alternator put out a lower voltage than 12 volts, the spin value goes down and the tc shows a negative turn that increases as the voltage gets less. This file shows you as the author. If you are comfortable with this change, commit it to cvs and the tc will be correct even for 12 volt systems.
This commit is contained in:
parent
86c3a3b5c4
commit
e89194b42a
1 changed files with 1 additions and 1 deletions
|
@ -94,7 +94,7 @@ void
|
||||||
TurnIndicator::update (double dt)
|
TurnIndicator::update (double dt)
|
||||||
{
|
{
|
||||||
// Get the spin from the gyro
|
// Get the spin from the gyro
|
||||||
double power = _electric_current_node->getDoubleValue() / 24.0;
|
double power = _electric_current_node->getDoubleValue() / 12.0;
|
||||||
_gyro.set_power_norm(power);
|
_gyro.set_power_norm(power);
|
||||||
_gyro.update(dt);
|
_gyro.update(dt);
|
||||||
double spin = _gyro.get_spin_norm();
|
double spin = _gyro.get_spin_norm();
|
||||||
|
|