Minor FDM shell performance improvement
Don't resolve all properties at run-time.
This commit is contained in:
parent
ed30b0c9a3
commit
5b8ab277fd
2 changed files with 23 additions and 9 deletions
|
@ -72,6 +72,16 @@ void FDMShell::init()
|
|||
{
|
||||
_props = globals->get_props();
|
||||
fgSetBool("/sim/fdm-initialized", false);
|
||||
|
||||
_wind_north = _props->getNode("environment/wind-from-north-fps", true);
|
||||
_wind_east = _props->getNode("environment/wind-from-east-fps", true);
|
||||
_wind_down = _props->getNode("environment/wind-from-down-fps", true);
|
||||
_control_fdm_atmo = _props->getNode("environment/params/control-fdm-atmosphere", true);
|
||||
_temp_degc = _props->getNode("environment/temperature-degc", true);
|
||||
_pressure_inhg = _props->getNode("environment/pressure-inhg", true);
|
||||
_density_slugft = _props->getNode("environment/density-slugft3", true);
|
||||
_data_logging = _props->getNode("/sim/temp/fdm-data-logging", true);
|
||||
|
||||
createImplementation();
|
||||
}
|
||||
|
||||
|
@ -138,23 +148,23 @@ void FDMShell::update(double dt)
|
|||
|
||||
// pull environmental data in, since the FDMs are lazy
|
||||
_impl->set_Velocities_Local_Airmass(
|
||||
_props->getDoubleValue("environment/wind-from-north-fps", 0.0),
|
||||
_props->getDoubleValue("environment/wind-from-east-fps", 0.0),
|
||||
_props->getDoubleValue("environment/wind-from-down-fps", 0.0));
|
||||
_wind_north->getDoubleValue(),
|
||||
_wind_east->getDoubleValue(),
|
||||
_wind_down->getDoubleValue());
|
||||
|
||||
if (_props->getBoolValue("environment/params/control-fdm-atmosphere")) {
|
||||
if (_control_fdm_atmo->getBoolValue()) {
|
||||
// convert from Rankine to Celsius
|
||||
double tempDegC = _props->getDoubleValue("environment/temperature-degc");
|
||||
double tempDegC = _temp_degc->getDoubleValue();
|
||||
_impl->set_Static_temperature((9.0/5.0) * (tempDegC + 273.15));
|
||||
|
||||
// convert from inHG to PSF
|
||||
double pressureInHg = _props->getDoubleValue("environment/pressure-inhg");
|
||||
double pressureInHg = _pressure_inhg->getDoubleValue();
|
||||
_impl->set_Static_pressure(pressureInHg * 70.726566);
|
||||
// keep in slugs/ft^3
|
||||
_impl->set_Density(_props->getDoubleValue("environment/density-slugft3"));
|
||||
_impl->set_Density(_density_slugft->getDoubleValue());
|
||||
}
|
||||
|
||||
bool doLog = _props->getBoolValue("/sim/temp/fdm-data-logging", false);
|
||||
bool doLog = _data_logging->getBoolValue();
|
||||
if (doLog != _dataLogging) {
|
||||
_dataLogging = doLog;
|
||||
_impl->ToggleDataLogging(doLog);
|
||||
|
|
|
@ -58,8 +58,12 @@ private:
|
|||
|
||||
TankPropertiesList _tankProperties;
|
||||
FGInterface* _impl;
|
||||
SGPropertyNode* _props; // root property tree for this FDM instance
|
||||
SGPropertyNode_ptr _props; // root property tree for this FDM instance
|
||||
bool _dataLogging;
|
||||
|
||||
SGPropertyNode_ptr _wind_north, _wind_east,_wind_down;
|
||||
SGPropertyNode_ptr _control_fdm_atmo,_temp_degc,_pressure_inhg;
|
||||
SGPropertyNode_ptr _density_slugft, _data_logging;
|
||||
};
|
||||
|
||||
#endif // of FG_FDM_SHELL_HXX
|
||||
|
|