Four different types of digital low-pass filters can be configured inside the
autopilot configuration file. The types of filter are:
* Exponential
* Double exponential
* Moving average
* Noise spike filter
Example:
pressure-rate-filterfalsedouble-exponential
/autopilot/internal/pressure-rate
0.1
This will filter the pressure-rate property. The output will be to a new
property called filtered-pressure-rate. You can select any numerical property
from the property tree. The input property will not be affected by the filter,
it will stay the same as it would if no filter was configured.
The name of the filter. Give it a sensible name!
If this tag is set to true debugging info will be printed on the
console.
The type of filter. This can be exponential, double-exponential,
moving-average or noise-spike.
The input property to be filtered. This should of course be a
numerical property, filtering a text string or a boolean value does not make
sense.