2013-11-04 13:13:22 +00:00
|
|
|
io.include("Aircraft/Generic/soaring-instrumentation-sdk.nas");
|
2010-05-28 22:15:10 +00:00
|
|
|
|
2013-11-04 13:13:22 +00:00
|
|
|
# Initialize exported properties
|
|
|
|
setprop("/instrumentation/ilec-sc7/volume", 0.8);
|
|
|
|
setprop("/instrumentation/ilec-sc7/audio", 2);
|
|
|
|
setprop("/instrumentation/ilec-sc7/mode", 1);
|
|
|
|
setprop("/instrumentation/ilec-sc7/sensitivity", 3);
|
|
|
|
setprop("/instrumentation/ilec-sc7/lcd-digits-abs", 0);
|
|
|
|
setprop("/instrumentation/ilec-sc7/lcd-digits-sgn", 0);
|
|
|
|
setprop("/instrumentation/ilec-sc7/te-reading-mps", 0);
|
|
|
|
setprop("/instrumentation/variometer/te-reading-mps", 0);
|
|
|
|
|
|
|
|
# Helper function for updating lcd display
|
|
|
|
var update_lcd_props = func(value) {
|
|
|
|
setprop("/instrumentation/ilec-sc7/lcd-digits-abs", math.abs(value));
|
|
|
|
setprop("/instrumentation/ilec-sc7/lcd-digits-sgn", (value < 0) ? 0 : 1);
|
|
|
|
};
|
|
|
|
|
|
|
|
# Instrument setup:
|
|
|
|
|
|
|
|
# One TE probe feeds two vario needles and a 25s averager.
|
|
|
|
# LCD digits are controlled by the.. um.. lcd_controller
|
|
|
|
# that switches between battery level, temperature and averager
|
|
|
|
# depending on mode switch posiion.
|
|
|
|
|
|
|
|
# Why a second needle? A digital vario is usually installed together
|
|
|
|
# with a mechanical one, so now we are at it, why not provide a bonus
|
|
|
|
# TE reading for it and avoid loading an extra script?
|
|
|
|
|
|
|
|
var probe = TotalEnergyProbe.new();
|
|
|
|
|
|
|
|
var sc7_needle = Dampener.new(
|
|
|
|
input: probe,
|
|
|
|
dampening: 3,
|
|
|
|
on_update: update_prop("/instrumentation/ilec-sc7/te-reading-mps"));
|
|
|
|
|
|
|
|
var extra_needle = Dampener.new(
|
|
|
|
input: probe,
|
|
|
|
dampening: 2.7,
|
|
|
|
on_update: update_prop("/instrumentation/variometer/te-reading-mps"));
|
|
|
|
|
|
|
|
var averager = Averager.new(
|
|
|
|
input: probe,
|
|
|
|
buffer_size: 25);
|
|
|
|
|
|
|
|
var battery_level = { output: 9.9 };
|
|
|
|
|
|
|
|
var temperature = PropertyReader.new(
|
|
|
|
property: "environment/temperature-degc",
|
|
|
|
scale: 0.1);
|
|
|
|
|
|
|
|
var lcd_controller = InputSwitcher.new(
|
|
|
|
inputs: [battery_level, averager, temperature],
|
|
|
|
active_input: 1,
|
|
|
|
on_update: update_lcd_props);
|
|
|
|
|
|
|
|
# Subscribe property listeners for instrument switches
|
|
|
|
setlistener("instrumentation/ilec-sc7/mode",
|
|
|
|
func(n) { lcd_controller.select_input(n.getValue()) }, 0, 0);
|
|
|
|
|
|
|
|
setlistener("instrumentation/ilec-sc7/sensitivity",
|
|
|
|
func(n) { sc7_needle.dampening = n.getValue() }, 0, 0);
|
|
|
|
|
|
|
|
# Wrap everything together into an instrument
|
2014-11-29 10:53:26 +00:00
|
|
|
var fast_instruments = UpdateLoop.new(
|
2013-11-04 13:13:22 +00:00
|
|
|
update_period: 0,
|
|
|
|
components: [probe, sc7_needle, extra_needle],
|
|
|
|
enable: 1);
|
|
|
|
|
2014-11-29 10:53:26 +00:00
|
|
|
var slow_instruments = UpdateLoop.new(
|
2013-11-04 13:13:22 +00:00
|
|
|
update_period: 1,
|
|
|
|
components: [averager, temperature, lcd_controller],
|
|
|
|
enable: 1);
|