A3XX: Fix FAULT light showing while systems are off on OH

This commit is contained in:
Joshua Davidson 2017-07-04 23:05:26 -04:00
parent 0c3579a7d0
commit 67a45e3728

View file

@ -887,6 +887,10 @@
<property>/systems/failures/elac1</property> <property>/systems/failures/elac1</property>
<value>1</value> <value>1</value>
</equals> </equals>
<equals>
<property>/controls/fctl/elac1</property>
<value>1</value>
</equals>
<equals> <equals>
<property>/controls/switches/annun-test</property> <property>/controls/switches/annun-test</property>
<value>1</value> <value>1</value>
@ -954,6 +958,10 @@
<property>/systems/failures/sec1</property> <property>/systems/failures/sec1</property>
<value>1</value> <value>1</value>
</equals> </equals>
<equals>
<property>/controls/fctl/sec1</property>
<value>1</value>
</equals>
<equals> <equals>
<property>/controls/switches/annun-test</property> <property>/controls/switches/annun-test</property>
<value>1</value> <value>1</value>
@ -1021,6 +1029,10 @@
<property>/systems/failures/fac1</property> <property>/systems/failures/fac1</property>
<value>1</value> <value>1</value>
</equals> </equals>
<equals>
<property>/controls/fctl/fac1</property>
<value>1</value>
</equals>
<equals> <equals>
<property>/controls/switches/annun-test</property> <property>/controls/switches/annun-test</property>
<value>1</value> <value>1</value>
@ -1088,6 +1100,10 @@
<property>/systems/failures/elac2</property> <property>/systems/failures/elac2</property>
<value>1</value> <value>1</value>
</equals> </equals>
<equals>
<property>/controls/fctl/elac2</property>
<value>1</value>
</equals>
<equals> <equals>
<property>/controls/switches/annun-test</property> <property>/controls/switches/annun-test</property>
<value>1</value> <value>1</value>
@ -1155,6 +1171,10 @@
<property>/systems/failures/sec2</property> <property>/systems/failures/sec2</property>
<value>1</value> <value>1</value>
</equals> </equals>
<equals>
<property>/controls/fctl/sec2</property>
<value>1</value>
</equals>
<equals> <equals>
<property>/controls/switches/annun-test</property> <property>/controls/switches/annun-test</property>
<value>1</value> <value>1</value>
@ -1222,6 +1242,10 @@
<property>/systems/failures/sec3</property> <property>/systems/failures/sec3</property>
<value>1</value> <value>1</value>
</equals> </equals>
<equals>
<property>/controls/fctl/sec3</property>
<value>1</value>
</equals>
<equals> <equals>
<property>/controls/switches/annun-test</property> <property>/controls/switches/annun-test</property>
<value>1</value> <value>1</value>
@ -1289,6 +1313,10 @@
<property>/systems/failures/fac2</property> <property>/systems/failures/fac2</property>
<value>1</value> <value>1</value>
</equals> </equals>
<equals>
<property>/controls/fctl/fac2</property>
<value>1</value>
</equals>
<equals> <equals>
<property>/controls/switches/annun-test</property> <property>/controls/switches/annun-test</property>
<value>1</value> <value>1</value>
@ -1357,6 +1385,10 @@
<property>/instrumentation/mk-viii/serviceable</property> <property>/instrumentation/mk-viii/serviceable</property>
<value>0</value> <value>0</value>
</equals> </equals>
<equals>
<property>/instrumentation/mk-viii/inputs/discretes/terr-inhibit</property>
<value>0</value>
</equals>
<equals> <equals>
<property>/controls/switches/annun-test</property> <property>/controls/switches/annun-test</property>
<value>1</value> <value>1</value>
@ -1424,6 +1456,10 @@
<property>/instrumentation/mk-viii/serviceable</property> <property>/instrumentation/mk-viii/serviceable</property>
<value>0</value> <value>0</value>
</equals> </equals>
<equals>
<property>/instrumentation/mk-viii/inputs/discretes/gpws-inhibit</property>
<value>0</value>
</equals>
<equals> <equals>
<property>/controls/switches/annun-test</property> <property>/controls/switches/annun-test</property>
<value>1</value> <value>1</value>