<?xml version="1.0"?>
<!-- Airbus A320 FWC -->
<!-- Copyright (c) 2019 Jonathan Redpath -->
<system name="A320: FWC">
<channel name="FWC" execrate="16">
<actuator name="/ECAM/phases/timer/eng1idle-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/phases/timer/eng1idle</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.033</rate_limit> <!-- 30 seconds -->
</actuator>
<actuator name="/ECAM/phases/timer/eng2idle-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/phases/timer/eng2idle</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.033</rate_limit> <!-- 30 seconds -->
</actuator>
<actuator name="/ECAM/phases/timer/to-inhibit-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/phases/timer/to-inhibit</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.33</rate_limit> <!-- 3 seconds -->
</actuator>
<actuator name="/ECAM/phases/timer/ldg-inhibit-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/phases/timer/ldg-inhibit</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.33</rate_limit> <!-- 3 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/bleed-1-fault-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/timer/bleed-1-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/bleed-2-fault-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/timer/bleed-2-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/apu-fault-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/apu-bleed-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/xbleed-fault-output">
<description>Timer for the ECAM system</description>
<input>/systems/pneumatics/warnings/crossbleed-disag</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/xbleed-fault-output-10"> <!-- 10 second delay on fall -->
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/crossbleed-fault-timer-was-one</input>
<rate_limit sense="decr">0.1</rate_limit> <!-- 10 seconds -->
<rate_limit sense="incr">120</rate_limit> <!-- Instant -->
</actuator>
<actuator name="/ECAM/warnings/timer/xbleed-fault-eng-fire">
<description>Timer for the ECAM system</description>
<input>/controls/engines/engine[0]/fire-btn</input>
<rate_limit>0.06666666666</rate_limit>
</actuator>
<actuator name="/ECAM/warnings/timer/prv-1-not-shut-apu-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/prv-1-not-shut-apu</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 second -->
</actuator>
<actuator name="/ECAM/warnings/timer/prv-2-not-shut-apu-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/prv-2-not-shut-apu</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 second -->
</actuator>
<actuator name="/ECAM/warnings/timer/prv-1-not-shut-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/prv-1-not-shut</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 second -->
</actuator>
<actuator name="/ECAM/warnings/timer/prv-2-not-shut-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/prv-2-not-shut</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 second -->
</actuator>
<actuator name="/ECAM/warnings/timer/bleed-1-and-2-low-temp-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/timer/bleed-1-and-2-low-temp</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.00185185</rate_limit> <!-- 540 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/bleed-1-low-temp-output">
<description>Timer for the ECAM system</description>
<input>/systems/pneumatics/warnings/lowtemp-1-mem</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.016666</rate_limit> <!-- 60 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/bleed-2-low-temp-output">
<description>Timer for the ECAM system</description>
<input>/systems/pneumatics/warnings/lowtemp-2-mem</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.016666</rate_limit> <!-- 60 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/bleed-1-off-60-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/bleed-1-off-60</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.016666</rate_limit> <!-- 60 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/bleed-2-off-60-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/bleed-2-off-60</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.016666</rate_limit> <!-- 60 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/bleed-1-off-5-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/bleed-1-off-5</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/bleed-2-off-5-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/bleed-2-off-5</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/eng-aice-1-open-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/eng-aice-1-open</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/eng-aice-2-open-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/eng-aice-2-open</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/eng-aice-1-closed-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/eng-aice-1-closed</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/eng-aice-2-closed-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/eng-aice-2-closed</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/wing-anti-ice-flipflop-set">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/wing-anti-ice-flipflop-set-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.0285714</rate_limit> <!-- 35 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/phase-1">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/timer/phase-1-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.5</rate_limit> <!-- 2 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/wing-anti-ice-25">
<description>Timer for the ECAM system</description>
<input>/controls/ice-protection/wing</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.04</rate_limit> <!-- 25 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/wing-anti-ice-left-closed-set">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/wing-anti-ice-left-closed-set-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.066666</rate_limit> <!-- 15 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/wing-anti-ice-right-closed-set">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/wing-anti-ice-right-closed-set-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.066666</rate_limit> <!-- 15 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/proc-wai-shutdown-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/proc-wai-shutdown-flipflop</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/wing-hi-pr-left">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/wing-hi-pr-left-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.025</rate_limit> <!-- 40 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/wing-hi-pr-right">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/wing-hi-pr-right-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.025</rate_limit> <!-- 40 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/cranking-35-sec">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/cranking-35-sec-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.028571</rate_limit> <!-- 35 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-1-fault-closed">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-1-fault-closed-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-2-fault-closed">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-2-fault-closed-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-1-disagree">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-1-disagree-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-2-disagree">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-2-disagree-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/ignition">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/ignition</input>
<rate_limit sense="incr">100</rate_limit> <!-- Instant -->
<rate_limit sense="decr">0.028571</rate_limit> <!-- 35 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-1-fault-5">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-1-fault-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.20</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-2-fault-5">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-2-fault-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.20</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-1-fault-2">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-1-fault-warning-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.50</rate_limit> <!-- 2 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-2-fault-2">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-2-fault-warning-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.50</rate_limit> <!-- 2 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-1-off">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-1-off-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.0166666</rate_limit> <!-- 60 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-2-off">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-2-off-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.0166666</rate_limit> <!-- 60 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/trim-air-fault">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/trim-air-fault-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/yaw-damper-1-fault">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/yaw-damper-1-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/yaw-damper-2-fault">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/yaw-damper-2-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/nav-gpws-terr-fault">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/nav-gpws-terr-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1.0</rate_limit> <!-- 1 second -->
</actuator>
<actuator name="/ECAM/warnings/timer/apu-gen-fault-reset">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/apu-gen-fault-reset</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.5</rate_limit> <!-- 2 seconds -->
</actuator>
</channel>
<channel name="ECAM" execrate="16">
<switch name="/ECAM/warnings/logic/apu-bleed-fault">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/systems/electrical/bus/dc-2 ge 25
/systems/electrical/relay/dc-ess-feed-bat/contact-pos eq 1
</test>
<test logic="OR">
<test logic="AND">
/systems/apu/available eq 1
/controls/apu/master eq 1
/controls/pneumatics/switches/apu eq 0
/systems/pneumatics/valves/apu-bleed-valve ne 0
</test>
<test logic="AND">
/systems/apu/available eq 1
/controls/apu/master eq 1
/controls/pneumatics/switches/apu eq 1
/systems/pneumatics/valves/apu-bleed-valve ne 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/prv-1-not-shut-apu">
<default value="0"/>
<test logic="AND" value="1">
/systems/apu/available eq 1
/controls/pneumatics/switches/apu eq 1
/systems/pneumatics/valves/engine-1-prv-valve-disag eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/prv-2-not-shut-apu">
<default value="0"/>
<test logic="AND" value="1">
/systems/apu/available eq 1
/controls/pneumatics/switches/apu eq 1
/systems/pneumatics/valves/engine-2-prv-valve-disag eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/prv-1-not-shut-apu-reset">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/controls/pneumatics/switches/bleed-1 eq 0
/ECAM/warnings/logic/engine-1-prv-valve-falling-pulse eq 0 <!-- inverse -->
</test>
/ECAM/warning-phase eq 1
<test logic="AND">
/engines/engine[0]/state eq 3
<test logic="AND">
/ECAM/warnings/logic/apu-bleed-sw-pulse eq 1
/controls/pneumatics/switches/apu eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/prv-2-not-shut-apu-reset">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/controls/pneumatics/switches/bleed-2 eq 0
/ECAM/warnings/logic/engine-2-prv-valve-falling-pulse eq 0 <!-- inverse -->
</test>
/ECAM/warning-phase eq 1
<test logic="AND">
/engines/engine[1]/state eq 3
<test logic="AND">
/ECAM/warnings/logic/apu-bleed-sw-pulse eq 1
/controls/pneumatics/switches/apu eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/prv-1-not-shut">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/prv-1-not-shut-apu-flipflop-output eq 1
<test logic="AND">
/engines/engine[0]/state ne 3
/systems/pneumatics/valves/engine-1-prv-valve-disag eq 1
</test>
<test logic="AND">
/systems/pneumatics/valves/starter-valve-1 ne 0
/systems/pneumatics/valves/engine-1-prv-valve-disag eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/prv-2-not-shut">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/prv-2-not-shut-apu-flipflop-output eq 1
<test logic="AND">
/engines/engine[1]/state ne 3
/systems/pneumatics/valves/engine-2-prv-valve-disag eq 1
</test>
<test logic="AND">
/systems/pneumatics/valves/starter-valve-2 ne 0
/systems/pneumatics/valves/engine-2-prv-valve-disag eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/crossbleed-fault-timer-was-one">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/timer/xbleed-fault-output eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/crossbleed-fault">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/timer/xbleed-fault-output eq 1
<test logic="AND">
<test logic="AND">
/ECAM/warnings/timer/xbleed-fault-output eq 0
/ECAM/warnings/timer/xbleed-fault-output-10 ne 0
</test>
<test logic="OR">
/ECAM/warnings/timer/xbleed-fault-eng-fire eq 0
/ECAM/warnings/timer/xbleed-fault-eng-fire eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/crossbleed-wai">
<default value="0"/>
<test logic="AND" value="1">
/systems/apu/available eq 1
/controls/pneumatics/switches/apu eq 1
/systems/pneumatics/valves/engine-1-prv-valve eq 0
/systems/pneumatics/valves/engine-2-prv-valve eq 0
/systems/pneumatics/warnings/crossbleed-disag-open eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-low-temp-reset">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/controls/ice-protection/wing eq 0
/ECAM/warnings/logic/wai-falling-pulse eq 0
</test>
/gear/gear[1]/wow eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-not-avail">
<default value="0"/>
<test logic="OR" value="1">
/engines/engine[0]/state ne 3
/controls/pneumatics/switches/bleed-1 eq 0
/systems/pneumatics/valves/engine-1-prv-valve-autoclose-cmd eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-not-avail">
<default value="0"/>
<test logic="OR" value="1">
/engines/engine[1]/state ne 3
/controls/pneumatics/switches/bleed-2 eq 0
/systems/pneumatics/valves/engine-2-prv-valve-autoclose-cmd eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-or-2-not-avail">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/bleed-1-not-avail eq 1
/ECAM/warnings/logic/bleed-2-not-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-apu-is-in-use">
<default value="0"/>
<test logic="AND" value="1">
/systems/apu/available eq 1
/controls/pneumatics/switches/apu eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-avail">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/bleed-1-not-avail eq 0
/ECAM/warnings/logic/bleed-apu-is-in-use eq 1
<test logic="AND">
/systems/pneumatics/valves/crossbleed-valve eq 1
/ECAM/warnings/logic/bleed-2-not-avail eq 0
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-avail">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/bleed-2-not-avail eq 0
<test logic="AND">
/systems/pneumatics/valves/crossbleed-valve eq 1
<test logic="OR">
/ECAM/warnings/logic/bleed-1-not-avail eq 0
/ECAM/warnings/logic/bleed-apu-is-in-use eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-wai-avail">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-apu-is-in-use eq 0
/ECAM/warnings/logic/bleed-1-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-wai-avail">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-apu-is-in-use eq 0
/ECAM/warnings/logic/bleed-2-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wai-on">
<default value="0"/>
<test logic="AND" value="1">
/controls/ice-protection/wing eq 1
<test logic="OR">
/systems/pneumatics/valves/wing-ice-1 eq 1
/systems/pneumatics/valves/wing-ice-2 eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-lo-temp-xbleed">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-2-wai-avail eq 1 <!-- deliberate -->
/systems/pneumatics/valves/crossbleed-valve eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-lo-temp-bleed">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-2-wai-avail eq 1
/controls/pneumatics/switches/bleed-1 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-lo-temp-pack">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-2-wai-avail eq 1
/controls/pneumatics/switches/pack-1 eq 1
/controls/pneumatics/switches/pack-2 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-lo-temp-unsucc">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/bleed-2-wai-avail eq 0
/ECAM/warnings/logic/bleed-1-lo-temp-xbleed eq 1
/ECAM/warnings/logic/bleed-1-lo-temp-bleed eq 1
/ECAM/warnings/logic/bleed-1-lo-temp-pack eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-lo-temp-xbleed">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-1-wai-avail eq 1 <!-- deliberate -->
/systems/pneumatics/valves/crossbleed-valve eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-lo-temp-bleed">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-1-wai-avail eq 1
/controls/pneumatics/switches/bleed-2 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-lo-temp-pack">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-1-wai-avail eq 1
/controls/pneumatics/switches/pack-1 eq 1
/controls/pneumatics/switches/pack-2 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-off-60">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/warnings/lowtemp-1-mem eq 0
/ECAM/warning-phase eq 6
/controls/pneumatics/switches/bleed-1 eq 0
/ECAM/warnings/logic/prv-1-not-shut eq 0
/ECAM/warnings/logic/bleed-1-off-flipflop eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-off-5">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/warnings/lowtemp-1-mem eq 0
/ECAM/warning-phase eq 2
/controls/pneumatics/switches/bleed-1 eq 0
/ECAM/warnings/logic/prv-1-not-shut eq 0
/ECAM/warnings/logic/bleed-1-off-flipflop eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-off-flipflop-set">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/valves/engine-1-prv-valve-disag eq 1
/controls/pneumatics/switches/bleed-1 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-off-flipflop-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 3
/ECAM/warning-phase eq 7
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-off-60">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/warnings/lowtemp-2-mem eq 0
/ECAM/warning-phase eq 6
/controls/pneumatics/switches/bleed-2 eq 0
/ECAM/warnings/logic/prv-2-not-shut eq 0
/ECAM/warnings/logic/bleed-2-off-flipflop eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-off-5">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/warnings/lowtemp-2-mem eq 0
/ECAM/warning-phase eq 2
/controls/pneumatics/switches/bleed-2 eq 0
/ECAM/warnings/logic/prv-2-not-shut eq 0
/ECAM/warnings/logic/bleed-2-off-flipflop eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-off-flipflop-set">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/valves/engine-2-prv-valve-disag eq 1
/controls/pneumatics/switches/bleed-2 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-off-flipflop-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 3
/ECAM/warning-phase eq 7
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng-aice-1-open">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/phases/timer/eng1idle-output ne 0
/systems/electrical/bus/dc-1 ge 25
/controls/ice-protection/lengfault eq 1
/controls/ice-protection/leng eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng-aice-2-open">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/phases/timer/eng2idle-output ne 0
/systems/electrical/bus/dc-2 ge 25
/controls/ice-protection/rengfault eq 1
/controls/ice-protection/reng eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng-aice-1-closed">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/phases/timer/eng1idle-output ne 0
/controls/ice-protection/lengfault eq 1
/controls/ice-protection/leng eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng-aice-2-closed">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/phases/timer/eng2idle-output ne 0
/controls/ice-protection/rengfault eq 1
/controls/ice-protection/reng eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wai-ground-pulse-set">
<default value="0"/>
<test logic="AND" value="1">
/gear/gear[1]/wow eq 0
/controls/ice-protection/wing eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-left-closed-set-input">
<default value="0"/>
<test logic="AND" value="1">
/controls/ice-protection/wing eq 1
/ECAM/warnings/logic/bleed-1-avail eq 1
<test logic="OR">
/systems/pneumatics/valves/wing-ice-1 eq 0
/systems/pneumatics/psi/engine-1-psi lt 13
</test>
<test logic="OR">
<test logic="AND">
/ECAM/warnings/logic/wai-ground-pulse-set eq 1
</test>
<test logic="AND">
/gear/gear[1]/wow eq 1
/ECAM/warnings/timer/wing-anti-ice-25 ne 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-right-closed-set-input">
<default value="0"/>
<test logic="AND" value="1">
/controls/ice-protection/wing eq 1
/ECAM/warnings/logic/bleed-2-avail eq 1
<test logic="OR">
/systems/pneumatics/valves/wing-ice-2 eq 0
/systems/pneumatics/psi/engine-2-psi lt 13
</test>
<test logic="OR">
<test logic="AND">
/ECAM/warnings/logic/wai-ground-pulse-set eq 1
</test>
<test logic="AND">
/gear/gear[1]/wow eq 1
/ECAM/warnings/timer/wing-anti-ice-25 ne 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/timer/phase-1-input">
<default value="0"/>
<test value="1">
/ECAM/warning-phase eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-left-closed-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/timer/phase-1 eq 1
<test logic="AND">
/systems/pneumatics/valves/wing-ice-1 eq 1
/controls/ice-protection/wing eq 1
/ECAM/warnings/logic/bleed-1-avail eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-right-closed-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/timer/phase-1 eq 1
<test logic="AND">
/systems/pneumatics/valves/wing-ice-2 eq 1
/controls/ice-protection/wing eq 1
/ECAM/warnings/logic/bleed-2-avail eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-flipflop-set-input">
<defualt value="0"/>
<test logic="AND" value="1">
/controls/ice-protection/wing eq 1
/gear/gear[1]/wow eq 1
/ECAM/warnings/logic/wai-on eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-flipflop-reset">
<defualt value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 10
</test>
</switch>
<switch name="/ECAM/warnings/logic/proc-wai-shutdown-set">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/valves/crossbleed-valve eq 0
/controls/engines/engine[0]/fire-btn eq 0
/controls/engines/engine[1]/fire-btn eq 0
/ECAM/warnings/logic/wai-ground-pulse eq 1
/ECAM/warnings/logic/wai-ground-pulse-set eq 1
<test logic="OR">
<test logic="AND">
/engines/engine[0]/state eq 3
/engines/engine[1]/state ne 3 <!-- TODO this must use ENG 1 FAIL from the ECAM warning see page 2856 of ESLD -->
</test>
<test logic="AND">
/engines/engine[0]/state ne 3
/engines/engine[1]/state eq 3
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/proc-wai-shutdown-reset">
<default value="0"/>
<test logic="OR" value="1">
/systems/pneumatics/valves/crossbleed-valve ne 0
/ECAM/warnings/logic/wai-on eq 0
<test logic="AND">
/ECAM/warnings/timer/phase-1-input eq 1
/ECAM/warnings/timer/phase-1-pulse eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-sys-fault">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/proc-wai-shutdown-output eq 1
<test logic="AND">
<test logic="OR">
/ECAM/warnings/logic/wai-ground-pulse eq 0
/ECAM/warnings/logic/wai-ground-pulse-set eq 0
</test>
<test logic="OR">
/ECAM/warnings/flipflop/wing-anti-ice-left-closed eq 1
/ECAM/warnings/flipflop/wing-anti-ice-right-closed eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/wai-phase-9-pulse-input">
<default value="0"/>
<test logic="AND" value="1">
/controls/ice-protection/wing eq 1
/ECAM/warning-phase eq 9
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-gnd-fault-set">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/wing-anti-ice-flipflop-set eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-gnd-fault">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/flipflop/wing-anti-ice-left-closed eq 0
/ECAM/warnings/flipflop/wing-anti-ice-right-closed eq 0
<test logic="OR">
/ECAM/warnings/logic/wai-phase-9-pulse-input eq 0
/ECAM/warnings/logic/wai-phase-9-pulse eq 0
</test>
/ECAM/warnings/logic/wing-anti-ice-gnd-fault-flipflop eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-hi-pr-left-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/wai-on eq 1
/systems/pneumatics/psi/engine-1-psi gt 49 <!-- rando number -->
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-hi-pr-right-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/wai-on eq 1
/systems/pneumatics/psi/engine-2-psi gt 49
</test>
</switch>
<switch name="/ECAM/warnings/logic/phase-10-pulse-input">
<default value="0"/>
<test value="1">
/ECAM/warning-phase eq 10
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-ovht-reset">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/ECAM/warnings/logic/phase-10-pulse-input eq 1
/ECAM/warnings/logic/phase-10-pulse eq 1
</test>
<test logic="AND">
/ECAM/warnings/logic/pack-1-pulse eq 1
/controls/pneumatics/switches/pack-1 eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-2-ovht-reset">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/ECAM/warnings/logic/phase-10-pulse-input eq 1
/ECAM/warnings/logic/phase-10-pulse eq 1
</test>
<test logic="AND">
/ECAM/warnings/logic/pack-2-pulse eq 1
/controls/pneumatics/switches/pack-2 eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-off-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 10
<test logic="AND">
/ECAM/warnings/logic/pack-1-pulse eq 1
/controls/pneumatics/switches/pack-1 eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-2-off-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 10
<test logic="AND">
/ECAM/warnings/logic/pack-2-pulse eq 1
/controls/pneumatics/switches/pack-2 eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/cranking-35-sec-input">
<default value="0"/>
<test value="1">
/controls/engines/engine-start-switch eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-fault-closed-input">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/controls/engines/engine-start-switch eq 0
/ECAM/warnings/timer/cranking-35-sec eq 1
</test>
/controls/pneumatics/switches/pack-1 eq 1
/systems/air-conditioning/valves/flow-control-valve-1 eq 0
/systems/air-conditioning/packs/pack-1-outlet-temp lt 260 <!-- confirm -->
/ECAM/warnings/logic/bleed-1-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-2-fault-closed-input">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/controls/engines/engine-start-switch eq 0
/ECAM/warnings/timer/cranking-35-sec eq 1
</test>
/controls/pneumatics/switches/pack-2 eq 1
/systems/air-conditioning/valves/flow-control-valve-2 eq 0
/systems/air-conditioning/packs/pack-2-outlet-temp lt 260 <!-- confirm -->
/ECAM/warnings/logic/bleed-2-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-disagree-input">
<default value="0"/>
<test logic="AND" value="1">
/systems/air-conditioning/warnings/pack-1-disagree eq 1
/ECAM/warnings/logic/bleed-1-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-2-disagree-input">
<default value="0"/>
<test logic="AND" value="1">
/systems/air-conditioning/warnings/pack-2-disagree eq 1
/ECAM/warnings/logic/bleed-2-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/ignition">
<default value="0"/>
<test logic="OR" value="1">
/systems/pneumatics/valves/starter-valve-1 ne 0
/systems/pneumatics/valves/starter-valve-2 ne 0
/controls/engines/engine-start-switch eq 2
/engines/engine[0]/state eq 1
/engines/engine[0]/state eq 2
/engines/engine[1]/state eq 1
/engines/engine[1]/state eq 2
</test>
</switch>
<switch name="/ECAM/warnings/logic/inhibit-pack-1-fault">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/timer/ignition eq 1
/ECAM/warnings/logic/ignition eq 1
<test logic="AND">
/controls/pneumatics/switches/pack-1 eq 0
/ECAM/warning-phase eq 2
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/inhibit-pack-2-fault">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/timer/ignition eq 1
/ECAM/warnings/logic/ignition eq 1
<test logic="AND">
/controls/pneumatics/switches/pack-2 eq 0
/ECAM/warning-phase eq 2
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-fault-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/inhibit-pack-1-fault eq 0
<test logic="OR">
/ECAM/warnings/timer/pack-1-fault-closed eq 1
/ECAM/warnings/timer/pack-1-disagree eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-2-fault-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/inhibit-pack-2-fault eq 0
<test logic="OR">
/ECAM/warnings/timer/pack-2-fault-closed eq 1
/ECAM/warnings/timer/pack-2-disagree eq 1
</test>
</test>
</switch>
<switch name="/ECAM/phases/monostable/phase-6-180">
<default value="0"/>
<test value="1">
/ECAM/warning-phase eq 6
</test>
</switch>
<switch name="/ECAM/phases/monostable/phase-6-180-inhibit">
<default value="0"/>
<test value="1">
/ECAM/phases/monostable/phase-6-180 eq 1
/ECAM/phases/monostable/phase-6-180-pulse eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-2-fault">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/controls/pneumatics/switches/pack-2 eq 0
<test logic="OR">
/ECAM/warnings/timer/pack-1-fault-5 eq 1
/systems/air-conditioning/warnings/pack-1-ovht eq 1
</test>
</test>
<test logic="AND">
/controls/pneumatics/switches/pack-1 eq 0
<test logic="OR">
/ECAM/warnings/timer/pack-2-fault-5 eq 1
/systems/air-conditioning/warnings/pack-2-ovht eq 1
</test>
</test>
<test logic="AND">
/controls/pneumatics/switches/pack-1 eq 0
/controls/pneumatics/switches/pack-2 eq 0
<test logic="AND">
/ECAM/warning-phase ne 1
/ECAM/warning-phase ne 2
/ECAM/warning-phase ne 10
/ECAM/phases/monostable/phase-6-180-inhibit ne 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/reset-pack-1-switch-cmd">
<default value="0"/>
<test logic="AND" value="1">
/controls/pneumatics/switches/pack-1 eq 0
/ECAM/warnings/timer/pack-1-fault-5 eq 0
/ECAM/warnings/flipflop/pack-1-ovht eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/reset-pack-2-switch-cmd">
<default value="0"/>
<test logic="AND" value="1">
/controls/pneumatics/switches/pack-2 eq 0
/ECAM/warnings/timer/pack-2-fault-5 eq 0
/ECAM/warnings/flipflop/pack-2-ovht eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-fault-warning-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/pack-1-fault-input eq 1
/ECAM/warnings/logic/pack-1-2-fault eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-2-fault-warning-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/pack-2-fault-input eq 1
/ECAM/warnings/logic/pack-1-2-fault eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-off-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-1-avail eq 1
/ECAM/warning-phase eq 6
/controls/pneumatics/switches/pack-1 eq 0
/ECAM/warnings/flipflop/pack-1-ovht eq 0
/ECAM/warnings/flipflop/pack-1-off eq 0
/ECAM/warnings/logic/bleed-1-low-temp-flipflop-output eq 0
<!-- TODO NOT HOT AIR VALVE STUCK OPEN OR OVHT -->
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-2-off-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-2-avail eq 1
/ECAM/warning-phase eq 6
/controls/pneumatics/switches/pack-2 eq 0
/ECAM/warnings/flipflop/pack-2-ovht eq 0
/ECAM/warnings/flipflop/pack-2-off eq 0
/ECAM/warnings/logic/bleed-2-low-temp-flipflop-output eq 0
<!-- TODO NOT HOT AIR VALVE STUCK OPEN OR OVHT -->
</test>
</switch>
<switch name="/ECAM/warnings/logic/trim-air-fault-inhibit">
<default value="0"/>
<test logic="OR" value="1">
/systems/electrical/bus/ac-ess lt 110
<test logic="AND">
<test logic="OR">
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 10
</test>
/systems/air-conditioning/valves/hot-air eq 0
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/trim-air-fault-input">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/systems/failures/pneumatics/trim-valve-cabin-aft eq 1
/systems/failures/pneumatics/trim-valve-cabin-fwd eq 1
/systems/failures/pneumatics/trim-valve-cockpit eq 1
</test>
/ECAM/warnings/logic/trim-air-fault-inhibit eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/cabin-fans-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/failures/pneumatics/cabin-fans eq 1
/systems/electrical/bus/dc-1 ge 25
/systems/electrical/bus/dc-2 ge 25
/systems/electrical/bus/ac-1 ge 110
/systems/electrical/bus/ac-2 ge 110
</test>
</switch>
<switch name="/ECAM/warnings/logic/rud-trav-lim-sys-1-fault-cmd">
<default value="0"/>
<test logic="AND" value="1">
/systems/navigation/adr/operating-1 eq 1
/systems/navigation/adr/operating-3 eq 1
/systems/electrical/bus/dc-ess-shed ge 25
/systems/electrical/bus/ac-1 ge 110
/systems/fctl/fac1-rtlu-avail eq 0
/systems/fctl/fac1-healthy-signal eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/rud-trav-lim-sys-2-fault-cmd">
<default value="0"/>
<test logic="AND" value="1">
/systems/navigation/adr/operating-2 eq 1
/systems/navigation/adr/operating-3 eq 1
/systems/electrical/bus/dc-2 ge 25
/systems/electrical/bus/ac-2 ge 110
/systems/fctl/fac2-rtlu-avail eq 0
/systems/fctl/fac2-healthy-signal eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/rud-trav-lim-sys-fault">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/rud-trav-lim-sys-1-fault-cmd eq 1
/ECAM/warnings/logic/rud-trav-lim-sys-2-fault-cmd eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/rud-trav-lim-sys-1-fault">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/rud-trav-lim-sys-1-fault-cmd eq 1
/ECAM/warnings/logic/rud-trav-lim-sys-fault eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/rud-trav-lim-sys-2-fault">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/rud-trav-lim-sys-2-fault-cmd eq 1
/ECAM/warnings/logic/rud-trav-lim-sys-fault eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/fac-12-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/bus/dc-ess-shed ge 25
/systems/electrical/bus/dc-2 ge 25
/systems/fctl/fac1-healthy-signal eq 0
/systems/fctl/fac2-healthy-signal eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/fac-1-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/navigation/adr/operating-1 eq 1
/systems/navigation/adr/operating-3 eq 1
/systems/electrical/bus/dc-ess-shed ge 25
/systems/electrical/bus/dc-ess ge 25
/systems/electrical/bus/ac-ess ge 110
/systems/fctl/fac1-healthy-signal eq 0
/systems/fctl/fac2-healthy-signal eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/fac-2-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/navigation/adr/operating-2 eq 1
/systems/navigation/adr/operating-3 eq 1
/systems/electrical/bus/dc-2 ge 25
/systems/electrical/bus/ac-2 ge 110
/systems/fctl/fac1-healthy-signal eq 1
/systems/fctl/fac2-healthy-signal eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/yaw-damper-1-fault-eng-start">
<default value="0"/>
<test logic="AND" value="1">
/controls/engines/engine[1]/cutoff-switch eq 0 <!-- opposite side -->
/systems/hydraulic/green-psi lt 1500
/ECAM/timer/ground-calc eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/yaw-damper-1-fault-adr">
<default value="0"/>
<test logic="AND" value="1">
/systems/navigation/adr/operating-1 eq 0
/systems/navigation/adr/operating-3 eq 0
<test logic="OR">
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 10
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/yaw-damper-1-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/navigation/adr/operating-1 eq 1
/systems/navigation/adr/operating-3 eq 1
/systems/electrical/bus/dc-ess-shed ge 25
/systems/electrical/bus/ac-1 ge 110
/ECAM/warnings/logic/yaw-damper-1-fault-eng-start eq 0
/systems/hydraulic/green-psi ge 1500
/ECAM/warnings/logic/yaw-damper-1-fault-adr eq 0
/ECAM/irs-in-align eq 0
/systems/fctl/yawdamper-1-active eq 0
/systems/fctl/fac1-healthy-signal eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/yaw-damper-2-fault-eng-start">
<default value="0"/>
<test logic="AND" value="1">
/controls/engines/engine[0]/cutoff-switch eq 0 <!-- opposite side -->
/systems/hydraulic/yellow-psi lt 1500
/ECAM/timer/ground-calc eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/yaw-damper-2-fault-adr">
<default value="0"/>
<test logic="AND" value="1">
/systems/navigation/adr/operating-2 eq 0
/systems/navigation/adr/operating-3 eq 0
<test logic="OR">
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 10
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/yaw-damper-2-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/navigation/adr/operating-2 eq 1
/systems/navigation/adr/operating-3 eq 1
/systems/electrical/bus/dc-2 ge 25
/systems/electrical/bus/ac-2 ge 110
/ECAM/warnings/logic/yaw-damper-2-fault-eng-start eq 0
/systems/hydraulic/yellow-psi ge 1500
/ECAM/warnings/logic/yaw-damper-2-fault-adr eq 0
/ECAM/irs-in-align eq 0
/systems/fctl/yawdamper-2-active eq 0
/systems/fctl/fac2-healthy-signal eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/adr-off-input">
<default value="1"/>
<test logic="OR" value="0">
/systems/navigation/adr/operating-1 eq 1
/systems/navigation/adr/operating-2 eq 1
/systems/navigation/adr/operating-3 eq 1
</test>
</switch>
<actuator name="/ECAM/warnings/logic/adr-off">
<input>/ECAM/warnings/logic/adr-off-input</input>
<rate_limit sense="decr">120</rate_limit>
<rate_limit sense="incr">0.5</rate_limit>
</actuator>
<switch name="/ECAM/warnings/logic/green-yellow-press-on-monostable-input">
<default value="0"/>
<test logic="AND" value="1">
/systems/hydraulic/warnings/green-lo-pr eq 0
/systems/hydraulic/warnings/yellow-lo-pr eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/yaw-damper-12-fault">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/irs-in-align eq 0
/ECAM/warnings/logic/adr-off ne 1
<test logic="OR">
/systems/electrical/bus/dc-ess-shed ge 25
/systems/electrical/bus/ac-1 ge 110
/systems/electrical/bus/dc-2 ge 25
/systems/electrical/bus/ac-2 ge 110
</test>
/ECAM/warnings/logic/green-yellow-press-on-monostable eq 0
/systems/hydraulic/green-psi ge 1500
/systems/hydraulic/yellow-psi ge 1500
/ECAM/warnings/logic/yaw-damper-1-fault eq 1
/ECAM/warnings/logic/yaw-damper-2-fault eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/nav-gpws-terr-fault">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/irs-in-align eq 0
/systems/navigation/adr/operating-1 eq 1
/systems/electrical/bus/ac-1 ge 110
/ECAM/warning-phase ne 1
/ECAM/warning-phase ne 10
/FMGC/FCU-working eq 1
/instrumentation/mk-viii/inputs/discretes/ta-tcf-inhibit eq 1
</test>
</switch>
</channel>
<channel name="Electrical Warnings" execrate="16">
<switch name="/ECAM/warnings/logic/gen-1-inop">
<default value="0"/>
<test logic="AND" value="1">
/engines/engine[0]/state eq 3
/systems/electrical/relay/gen-1-glc/contact-pos eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/gen-1-fault-set">
<default value="0"/>
<test logic="AND" value="1">
/controls/electrical/switches/gen-1 eq 1
/controls/electrical/switches/idg-1-disc eq 1
/ECAM/warnings/logic/gen-1-inop eq 1
</test>
</switch>
<actuator name="/ECAM/warnings/timer/gen-1-fault-set">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/gen-1-fault-set</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1818</rate_limit> <!-- 5.5 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/gen-1-fault-set-output">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/timer/gen-1-fault-set eq 1
</test>
</switch>
<actuator name="/ECAM/warnings/logic/glc-1-online-2-sec">
<input>/systems/electrical/relay/gen-1-glc/contact-pos</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.5</rate_limit> <!-- 2 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/gen-1-fault-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 10
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
/ECAM/warnings/logic/glc-1-online-2-sec eq 1
<!-- todo smoke + gen line pb -->
</test>
</switch>
<switch name="/ECAM/warnings/logic/gen-1-fault-on-off-set">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/flipflop/gen-1-fault eq 1
<test logic="AND">
/ECAM/warnings/logic/gen-1-pulse eq 1
/controls/electrical/switches/gen-1 eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/gen-1-fault-on-off-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/flipflop/gen-1-fault eq 0
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 10
</test>
</switch>
<switch name="/ECAM/warnings/logic/gen-2-inop">
<default value="0"/>
<test logic="AND" value="1">
/engines/engine[1]/state eq 3
/systems/electrical/relay/gen-2-glc/contact-pos eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/gen-2-fault-set">
<default value="0"/>
<test logic="AND" value="1">
/controls/electrical/switches/gen-2 eq 1
/controls/electrical/switches/idg-2-disc eq 1
/ECAM/warnings/logic/gen-2-inop eq 1
</test>
</switch>
<actuator name="/ECAM/warnings/timer/gen-2-fault-set">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/gen-2-fault-set</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1818</rate_limit> <!-- 5.5 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/gen-2-fault-set-output">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/timer/gen-2-fault-set eq 1
</test>
</switch>
<actuator name="/ECAM/warnings/logic/glc-2-online-2-sec">
<input>/systems/electrical/relay/gen-2-glc/contact-pos</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.5</rate_limit> <!-- 2 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/gen-2-fault-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 10
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
/ECAM/warnings/logic/glc-2-online-2-sec eq 1
<!-- todo smoke + gen line pb -->
</test>
</switch>
<switch name="/ECAM/warnings/logic/gen-2-fault-on-off-set">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/flipflop/gen-2-fault eq 1
<test logic="AND">
/ECAM/warnings/logic/gen-2-pulse eq 1
/controls/electrical/switches/gen-2 eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/gen-2-fault-on-off-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/flipflop/gen-2-fault eq 0
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 10
</test>
</switch>
<switch name="/ECAM/warnings/logic/apu-gen-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/apu/available eq 1
/systems/electrical/sources/apu/gcu-fault eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/apu-gen-fault-set">
<default value="0"/>
<test logic="AND" value="1">
/controls/electrical/switches/apu eq 1
/ECAM/warnings/logic/apu-gen-fault eq 1
</test>
</switch>
<actuator name="/ECAM/warnings/timer/apu-gen-fault-set">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/apu-gen-fault-set</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/apu-gen-fault-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 1
<test logic="AND">
/systems/apu/available eq 1
/controls/electrical/switches/apu eq 1
/systems/electrical/sources/apu/gcu-fault eq 0
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/apu-gen-fault-on-off-set">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/flipflop/apu-gen-fault eq 1
<test logic="AND">
/ECAM/warnings/logic/apu-elec-gen-pulse eq 1
/controls/electrical/switches/apu eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/apu-gen-fault-on-off-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/flipflop/apu-gen-fault eq 0
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 10
</test>
</switch>
<switch name="/ECAM/warnings/logic/BLUE-EMER-ELEC">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/hyd/blue-abnorm-lo-pr eq 1
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
/systems/electrical/some-electric-thingie/emer-elec-config-20-sec eq 1
</test>
</switch>
<actuator name="/ECAM/warnings/logic/elec/gen-1-pb">
<input>/controls/electrical/switches/gen-1</input>
<rate_limit sense="decr">0.2</rate_limit> <!-- 5 seconds -->
<rate_limit sense="incr">120</rate_limit>
</actuator>
<actuator name="/ECAM/warnings/logic/elec/gen-2-pb">
<input>/controls/electrical/switches/gen-2</input>
<rate_limit sense="decr">0.2</rate_limit> <!-- 5 seconds -->
<rate_limit sense="incr">120</rate_limit>
</actuator>
<switch name="/ECAM/warnings/logic/elec/gen-off-60-sec">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warning-phase eq 6
</test>
</switch>
<actuator name="/ECAM/warnings/logic/elec/gen-off-60-sec-output">
<input>/ECAM/warnings/logic/elec/gen-off-60-sec</input>
<rate_limit sense="incr">0.01666666666</rate_limit> <!-- 60 seconds -->
<rate_limit sense="decr">120</rate_limit>
</actuator>
<switch name="/ECAM/warnings/logic/elec/gen-1-off-60-sec-2">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warning-phase ne 6
/engines/engine[0]/state eq 3
</test>
</switch>
<actuator name="/ECAM/warnings/logic/elec/gen-1-off-60-sec-2-output">
<input>/ECAM/warnings/logic/elec/gen-1-off-60-sec-2</input>
<rate_limit sense="incr">0.01666666666</rate_limit> <!-- 60 seconds -->
<rate_limit sense="decr">120</rate_limit>
</actuator>
<switch name="/ECAM/warnings/logic/elec/gen-2-off-60-sec-2">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warning-phase ne 6
/engines/engine[1]/state eq 3
</test>
</switch>
<actuator name="/ECAM/warnings/logic/elec/gen-2-off-60-sec-2-output">
<input>/ECAM/warnings/logic/elec/gen-2-off-60-sec-2</input>
<rate_limit sense="incr">0.01666666666</rate_limit> <!-- 60 seconds -->
<rate_limit sense="decr">120</rate_limit>
</actuator>
<switch name="/ECAM/warnings/logic/elec/gen-1-off">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/elec/gen-1-pb eq 0
/ECAM/warnings/flipflop/gen-1-fault eq 0
/controls/electrical/switches/idg-1-disc eq 1
<test logic="OR">
/ECAM/warnings/logic/elec/gen-off-60-sec-output eq 1
/ECAM/warnings/logic/elec/gen-1-off-60-sec-2-output eq 1
<test logic="AND">
/ECAM/warning-phase eq 6
/ECAM/warnings/logic/gen-1-2-no-oper eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/elec/gen-2-off">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/elec/gen-2-pb eq 0
/ECAM/warnings/flipflop/gen-2-fault eq 0
/controls/electrical/switches/idg-2-disc eq 1
<test logic="OR">
/ECAM/warnings/logic/elec/gen-off-60-sec-output eq 1
/ECAM/warnings/logic/elec/gen-2-off-60-sec-2-output eq 1
<test logic="AND">
/ECAM/warning-phase eq 6
/ECAM/warnings/logic/gen-1-2-no-oper eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/SSLATEXT">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/BLUE-EMER-ELEC NE 1
fcs/slat-pos-rate eq 0
fcs/slat-pos-deg ge 2
</test>
</switch>
<switch name="/ECAM/warnings/logic/SFLAPEXT">
<default value="0"/>
<test logic="AND" value="1">
fcs/flap-pos-rate eq 0
fcs/flap-pos-deg ge 2
</test>
</switch>
<switch name="/ECAM/warnings/logic/gen-1-2-no-oper">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/ECAM/warnings/flipflop/gen-1-fault eq 1
/controls/electrical/switches/idg-1-disc eq 0
/ECAM/warnings/logic/elec/gen-1-off eq 1
</test>
<test logic="OR">
/ECAM/warnings/flipflop/gen-2-fault eq 1
/controls/electrical/switches/idg-2-disc eq 0
/ECAM/warnings/logic/elec/gen-2-off eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/dc-2-fuel-consumption-increased">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/timer/ground-calc eq 0
/ECAM/dual-failure-enabled eq 0
<test logic="OR">
<test logic="AND">
<test logic="OR">
/ECAM/warnings/hyd/green-abnorm-lo-pr eq 1
/systems/electrical/bus/dc-ess lt 25
</test>
/ECAM/warnings/logic/SFLAPEXT eq 1
</test>
<test logic="AND">
<test logic="OR">
/ECAM/warnings/hyd/blue-abnorm-lo-pr eq 1
/systems/electrical/bus/dc-ess lt 25
</test>
/ECAM/warnings/logic/SSLATEXT eq 1
</test>
<test logic="AND">
<test logic="OR">
<test logic="AND">
hydraulics/aileron-l/pressure-switch-or eq 1
<test logic="OR">
/systems/fctl/elac1 eq 0
/systems/hydraulic/blue-psi lt 1500
</test>
/ECAM/warnings/logic/BLUE-EMER-ELEC ne 1
</test>
<test logic="AND">
hydraulics/aileron-r/pressure-switch-or eq 1
<test logic="OR">
/systems/fctl/elac1 eq 0
/systems/hydraulic/green-psi lt 1500
</test>
</test>
</test>
<test logic="OR">
/gear/gear[0]/position-norm eq 0
/ECAM/warnings/hyd/blue-abnorm-lo-pr eq 0
</test>
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/dc-ess-fuel-consumption-increased">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/timer/ground-calc eq 0
/ECAM/dual-failure-enabled eq 0
<test logic="OR">
<test logic="AND">
<test logic="OR">
/ECAM/warnings/hyd/yellow-abnorm-lo-pr eq 1
/systems/electrical/bus/dc-2 lt 25
</test>
/ECAM/warnings/logic/SFLAPEXT eq 1
</test>
<test logic="AND">
<test logic="OR">
<test logic="AND">
/ECAM/warnings/hyd/blue-abnorm-lo-pr ne 1
/ECAM/warnings/hyd/green-abnorm-lo-pr eq 1
</test>
/systems/electrical/bus/dc-2 lt 25
</test>
/ECAM/warnings/logic/SSLATEXT eq 1
<test logic="OR">
/ECAM/warnings/hyd/blue-abnorm-lo-pr eq 0
/systems/electrical/bus/ac-1 ge 110
</test>
</test>
<test logic="AND">
<test logic="OR">
<test logic="AND">
hydraulics/aileron-l/pressure-switch-or eq 1
<test logic="OR">
/systems/fctl/elac2 eq 0
/systems/hydraulic/green-psi lt 1500
</test>
/ECAM/warnings/logic/BLUE-EMER-ELEC ne 1
</test>
<test logic="AND">
hydraulics/aileron-r/pressure-switch-or eq 1
<test logic="OR">
/systems/fctl/elac2 eq 0
/systems/hydraulic/blue-psi lt 1500
</test>
</test>
</test>
</test>
<test logic="AND">
/systems/electrical/bus/ac-1 ge 110
/ECAM/warnings/hyd/green-abnorm-lo-pr eq 0
<test logic="OR">
<test logic="AND">
/ECAM/warnings/hyd/blue-abnorm-lo-pr eq 1
<test logic="OR">
hydraulics/spoiler-l3/final-deg gt 0.01
hydraulics/spoiler-r3/final-deg gt 0.01
</test>
</test>
<test logic="AND">
/ECAM/warnings/hyd/blue-abnorm-lo-pr eq 1
<test logic="OR">
<test logic="AND">
hydraulics/aileron-l/pressure-switch-or eq 1
<test logic="OR">
/systems/fctl/elac2 eq 0
/systems/hydraulic/green-psi lt 1500
</test>
/ECAM/warnings/logic/BLUE-EMER-ELEC ne 1
</test>
<test logic="AND">
hydraulics/aileron-r/pressure-switch-or eq 1
<test logic="OR">
/systems/fctl/elac1 eq 0
/systems/hydraulic/green-psi lt 1500
</test>
</test>
</test>
</test>
</test>
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/dc-2-fms-predictions-unreliable">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/dc-2-fuel-consumption-increased eq 1
/systems/electrical/relay/dc-ess-shed-switch/contact-pos eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/dc-ess-fms-predictions-unreliable">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/dc-ess-fuel-consumption-increased eq 1
/systems/electrical/bus/dc-2 ge 25
</test>
</switch>
<switch name="/ECAM/warnings/logic/dc-emer-config">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/some-electric-thingie/emer-elec-config ne 1
/systems/electrical/bus/dc-1 lt 25
/systems/electrical/bus/dc-2 lt 25
/systems/electrical/bus/dc-ess lt 25
</test>
</switch>
<actuator name="/ECAM/warnings/logic/dc-emer-config-output">
<input>/ECAM/warnings/logic/dc-emer-config</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">5</rate_limit> <!-- 0.2 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/dc-1-2">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/some-electric-thingie/emer-elec-config ne 1
/systems/electrical/bus/dc-1 lt 25
/systems/electrical/bus/dc-2 lt 25
/ECAM/warnings/logic/dc-emer-config ne 1
</test>
</switch>
<actuator name="/ECAM/warnings/logic/dc-1-2-output">
<input>/ECAM/warnings/logic/dc-1-2</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.5</rate_limit> <!-- 2 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/dc-ess-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/bus/dc-ess lt 25
/ECAM/warnings/logic/dc-emer-config ne 1
</test>
</switch>
<actuator name="/ECAM/warnings/logic/dc-ess-output">
<input>/ECAM/warnings/logic/dc-ess-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.5</rate_limit> <!-- 2 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/dc-bat-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/bus/dc-bat lt 25
/ECAM/warnings/logic/dc-emer-config ne 1
/systems/electrical/some-electric-thingie/emer-elec-config ne 1
</test>
</switch>
<actuator name="/ECAM/warnings/logic/dc-bat-output">
<input>/ECAM/warnings/logic/dc-bat-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">5</rate_limit> <!-- 0.2 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/dc-1-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/bus/dc-1 lt 25
/systems/electrical/bus/dc-2 ge 25
/systems/electrical/some-electric-thingie/emer-elec-config ne 1
</test>
</switch>
<actuator name="/ECAM/warnings/logic/dc-1-output">
<input>/ECAM/warnings/logic/dc-1-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.5</rate_limit> <!-- 2 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/dc-2-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/bus/dc-2 lt 25
/systems/electrical/bus/dc-1 ge 25
/systems/electrical/some-electric-thingie/emer-elec-config ne 1
</test>
</switch>
<actuator name="/ECAM/warnings/logic/dc-2-output">
<input>/ECAM/warnings/logic/dc-2-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.5</rate_limit> <!-- 2 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/ac-1-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/bus/ac-1 lt 110
/systems/electrical/some-electric-thingie/emer-elec-config ne 1
</test>
</switch>
<actuator name="/ECAM/warnings/logic/ac-1-output">
<input>/ECAM/warnings/logic/ac-1-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">5</rate_limit> <!-- 0.2 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/ac-2-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/bus/ac-2 lt 110
/systems/electrical/some-electric-thingie/emer-elec-config ne 1
</test>
</switch>
<actuator name="/ECAM/warnings/logic/ac-2-output">
<input>/ECAM/warnings/logic/ac-2-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">5</rate_limit> <!-- 0.2 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/ac-ess-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/bus/ac-ess lt 110
/systems/electrical/some-electric-thingie/emer-elec-config ne 1
</test>
</switch>
<actuator name="/ECAM/warnings/logic/ac-ess-output">
<input>/ECAM/warnings/logic/ac-ess-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">5</rate_limit> <!-- 0.2 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/dc-ess-shed-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/bus/dc-ess-shed lt 25
/systems/electrical/bus/dc-ess ge 25
<test logic="OR">
/systems/electrical/some-electric-thingie/emer-elec-config-10-sec ne 1
/systems/electrical/some-electric-thingie/emer-elec-config ne 1
</test>
</test>
</switch>
<actuator name="/ECAM/warnings/logic/dc-ess-shed-output">
<input>/ECAM/warnings/logic/dc-ess-shed-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.5</rate_limit> <!-- 2 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/ac-ess-shed-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/bus/ac-ess-shed lt 110
/systems/electrical/bus/ac-ess ge 110
<test logic="OR">
/systems/electrical/some-electric-thingie/emer-elec-config-10-sec ne 1
/systems/electrical/some-electric-thingie/emer-elec-config ne 1
</test>
</test>
</switch>
<actuator name="/ECAM/warnings/logic/ac-ess-shed-output">
<input>/ECAM/warnings/logic/ac-ess-shed-fault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.5</rate_limit> <!-- 2 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/ac-ess-bus-altn-feed-input">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/bus/ac-1 ge 110
/controls/electrical/switches/ac-ess-feed eq 0
/systems/electrical/relay/ac-ess-feed-2/output ge 110
</test>
</switch>
<actuator name="/ECAM/warnings/logic/ac-ess-bus-altn-feed-output">
<input>/ECAM/warnings/logic/ac-ess-bus-altn-feed-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">2</rate_limit> <!-- 0.5 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/ac-ess-bus-altn-feed">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/some-electric-thingie/emer-elec-config ne 1
/systems/electrical/bus/ac-ess ge 25
/ECAM/warnings/logic/ac-ess-bus-altn-feed-output eq 1
</test>
</switch>
</channel>
<channel name="STALL" execrate="16">
<switch name="/ECAM/warnings/logic/stall/phase-4">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 4
</test>
</switch>
<switch name="/ECAM/warnings/logic/stall/phase-flipflop-set">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
<test logic="AND">
/ECAM/warnings/logic/stall/phase-8-output eq 0
/ECAM/phases/monostable/phase-8 eq 0
</test>
/ECAM/warning-phase eq 7
</test>
<test logic="AND">
<test logic="AND">
/ECAM/warnings/logic/stall/phase-4-output eq 0
/ECAM/warnings/logic/stall/phase-4 eq 0
</test>
/ECAM/warning-phase eq 5
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/stall/phase-5">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 5
</test>
</switch>
<switch name="/ECAM/warnings/logic/stall/phase-flipflop-reset">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/ECAM/warnings/logic/stall/phase-5-output eq 0
/ECAM/warnings/logic/stall/phase-5 eq 0
</test>
/ECAM/warning-phase eq 6
</test>
</switch>
<switch name="/ECAM/warnings/logic/stall/stall-warn-inhibit">
<default value="0"/>
<test logic="AND" value="1">
/instrumentation/radar-altimeter[0]/radar-altitude-ft-corrected lt 1500
/instrumentation/radar-altimeter[1]/radar-altitude-ft-corrected lt 1500
/it-fbw/law eq 0
/ECAM/warnings/logic/stall/phase-flipflop eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/stall/stall-warn">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
<test logic="AND">
/it-fbw/law eq 0
fcs/slat-pos-deg lt 15
<test logic="OR">
<test logic="AND">
/systems/navigation/adr/output/aoa-1 ge 13.5
/systems/navigation/adr/operating-1 eq 1
</test>
<test logic="AND">
/systems/navigation/adr/output/aoa-2 ge 13.5
/systems/navigation/adr/operating-2 eq 1
</test>
<test logic="AND">
/systems/navigation/adr/output/aoa-3 ge 13.5
/systems/navigation/adr/operating-3 eq 1
</test>
</test>
</test>
<test logic="AND">
/it-fbw/law eq 0
fcs/slat-pos-deg ge 15
<test logic="AND">
/systems/navigation/adr/output/aoa-1 ge 22
/systems/navigation/adr/operating-1 eq 1
</test>
<test logic="AND">
/systems/navigation/adr/output/aoa-2 ge 22
/systems/navigation/adr/operating-2 eq 1
</test>
<test logic="AND">
/systems/navigation/adr/output/aoa-3 ge 22
/systems/navigation/adr/operating-3 eq 1
</test>
</test>
<test logic="AND">
/it-fbw/law ne 0
fcs/slat-pos-deg lt 15
<test logic="OR">
<test logic="AND">
/systems/navigation/adr/output/aoa-1 ge 8
/systems/navigation/adr/operating-1 eq 1
</test>
<test logic="AND">
/systems/navigation/adr/output/aoa-2 ge 8
/systems/navigation/adr/operating-2 eq 1
</test>
<test logic="AND">
/systems/navigation/adr/output/aoa-3 ge 8
/systems/navigation/adr/operating-3 eq 1
</test>
</test>
</test>
<test logic="AND">
/it-fbw/law ne 0
fcs/slat-pos-deg ge 15
<test logic="AND">
/systems/navigation/adr/output/aoa-1 ge 14
/systems/navigation/adr/operating-1 eq 1
</test>
<test logic="AND">
/systems/navigation/adr/output/aoa-2 ge 14
/systems/navigation/adr/operating-2 eq 1
</test>
<test logic="AND">
/systems/navigation/adr/output/aoa-3 ge 14
/systems/navigation/adr/operating-3 eq 1
</test>
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/stall/stall-warn-on">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/ECAM/warning-phase eq 5
/ECAM/warning-phase eq 6
/ECAM/warning-phase eq 7
</test>
/ECAM/warnings/logic/stall/stall-warn eq 1
/ECAM/warnings/logic/stall/stall-warn-inhibit eq 0
</test>
</switch>
</channel>
<channel name="ENG" execrate="16">
<switch name="/ECAM/warnings/logic/eng/ground-spoilers">
<default value="0"/>
<test logic="AND" value="1">
spoilers/max-spoiler eq 1
spoilers/main-cmd gt 0
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/ground-spoilers-output">
<input>/ECAM/warnings/logic/eng/ground-spoilers</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">2</rate_limit> <!-- 0.5 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/ground-retard">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/timer/ground-calc eq 1
/ECAM/warnings/logic/eng/ground-spoilers-output eq 1
<test logic="AND">
<test logic="OR">
/ECAM/warning-phase eq 6
/ECAM/warning-phase eq 7
</test>
<test logic="AND">
/ECAM/phases/monostable/phase-8 eq 0
/ECAM/phases/monostable/phase-8-output eq 0
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-1-tla-abv-6">
<default value="0"/>
<test logic="OR" value="1">
fadec/control-1/lever/angle ge 6
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-1-tla-abv-6-2">
<default value="0"/>
<test logic="AND" value="1">
fadec/control-1/lever/angle ge 6
/ECAM/phases/phase-calculation/takeoff-power eq 0
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/eng-1-tla-abv-6-output">
<input>/ECAM/warnings/logic/eng/eng-1-tla-abv-6</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/eng/eng-1-tla-abv-6-2-output">
<input>/ECAM/warnings/logic/eng/eng-1-tla-abv-6-2</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/eng-1-tla-idle">
<default value="0"/>
<test logic="OR" value="1">
fadec/control-1/lever/angle lt 2.6
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/eng-1-tla-idle-output">
<input>/ECAM/warnings/logic/eng/eng-1-tla-idle</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/eng-1-reverse">
<default value="0"/>
<test logic="OR" value="1">
/engines/engine[0]/reverser-pos-norm gt 0
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/eng-1-reverse-output">
<input>/ECAM/warnings/logic/eng/eng-1-reverse</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/eng-2-tla-abv-6">
<default value="0"/>
<test logic="OR" value="1">
fadec/control-2/lever/angle ge 6
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-2-tla-abv-6-2">
<default value="0"/>
<test logic="AND" value="1">
fadec/control-2/lever/angle ge 6
/ECAM/phases/phase-calculation/takeoff-power eq 0
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/eng-2-tla-abv-6-output">
<input>/ECAM/warnings/logic/eng/eng-2-tla-abv-6</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/eng/eng-2-tla-abv-6-2-output">
<input>/ECAM/warnings/logic/eng/eng-2-tla-abv-6-2</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/eng-2-tla-idle">
<default value="0"/>
<test logic="OR" value="1">
fadec/control-2/lever/angle lt 2.6
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/eng-2-tla-idle-output">
<input>/ECAM/warnings/logic/eng/eng-2-tla-idle</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/eng-2-reverse">
<default value="0"/>
<test logic="OR" value="1">
/engines/engine[1]/reverser-pos-norm gt 0
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/eng-2-reverse-output">
<input>/ECAM/warnings/logic/eng/eng-2-reverse</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/eng-1-retard-case-1">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/eng/eng-1-tla-abv-6-output eq 1
/engines/engine[0]/state eq 3
<test logic="AND">
/engines/engine[1]/state eq 3
<test logic="OR">
<test logic="AND">
/ECAM/warnings/logic/eng/eng-2-reverse eq 1
/ECAM/warnings/logic/eng/eng-1-retard-case-2 eq 0
/ECAM/warnings/logic/eng/eng-1-retard-case-2-fall-output eq 0
</test>
/ECAM/warnings/logic/eng/eng-2-reverse-output eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-1-retard-case-2">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/eng/eng-1-tla-abv-6-2-output eq 1
/engines/engine[0]/state eq 3
<test logic="AND">
/engines/engine[1]/state eq 3
<test logic="OR">
/ECAM/warnings/logic/eng/eng-2-tla-idle-output eq 1
<test logic="AND">
/ECAM/warnings/logic/eng/eng-2-reverse-fall eq 0
/ECAM/warnings/logic/eng/eng-2-reverse eq 0
/ECAM/warnings/logic/eng/eng-2-tla-idle eq 1
</test>
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-2-retard-case-1">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/eng/eng-2-tla-abv-6-output eq 1
/engines/engine[1]/state eq 3
<test logic="AND">
/engines/engine[0]/state eq 3
<test logic="OR">
<test logic="AND">
/ECAM/warnings/logic/eng/eng-1-reverse eq 1
/ECAM/warnings/logic/eng/eng-2-retard-case-2 eq 0
/ECAM/warnings/logic/eng/eng-2-retard-case-2-fall-output eq 0
</test>
/ECAM/warnings/logic/eng/eng-1-reverse-output eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-2-retard-case-2">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/eng/eng-2-tla-abv-6-2-output eq 1
/engines/engine[1]/state eq 3
<test logic="AND">
/engines/engine[0]/state eq 3
<test logic="OR">
/ECAM/warnings/logic/eng/eng-1-tla-idle-output eq 1
<test logic="AND">
/ECAM/warnings/logic/eng/eng-1-reverse-fall eq 0
/ECAM/warnings/logic/eng/eng-1-reverse eq 0
/ECAM/warnings/logic/eng/eng-1-tla-idle eq 1
</test>
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-1-thr-lvr-abv-idle-set">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/eng/ground-retard eq 1
/velocities/groundspeed-kt gt 40
<test logic="OR">
/ECAM/warnings/logic/eng/eng-1-retard-case-1 eq 1
/ECAM/warnings/logic/eng/eng-1-retard-case-2 eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-1-thr-lvr-abv-idle-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/eng/ground-retard eq 0
<test logic="AND">
/ECAM/warnings/logic/eng/eng-1-retard-case-1 eq 0
/ECAM/warnings/logic/eng/eng-1-retard-case-2 eq 0
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-2-thr-lvr-abv-idle-set">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/eng/ground-retard eq 1
/velocities/groundspeed-kt gt 40
<test logic="OR">
/ECAM/warnings/logic/eng/eng-2-retard-case-1 eq 1
/ECAM/warnings/logic/eng/eng-2-retard-case-2 eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-2-thr-lvr-abv-idle-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/eng/ground-retard eq 0
<test logic="AND">
/ECAM/warnings/logic/eng/eng-2-retard-case-1 eq 0
/ECAM/warnings/logic/eng/eng-2-retard-case-2 eq 0
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/new-retard-logic">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/eng/eng-1-thr-lvr-abv-idle eq 1
/ECAM/warnings/logic/eng/eng-2-thr-lvr-abv-idle eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/thr-lever-1-mcl-mct">
<default value="0"/>
<test logic="AND" value="1">
/engines/engine[0]/n2-actual ge 59.4
<test logic="OR">
fadec/control-1/detent eq 2
fadec/control-1/detent eq 3
</test>
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/thr-lever-1-mcl-mct-output">
<input>/ECAM/warnings/logic/eng/thr-lever-1-mcl-mct</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.25</rate_limit> <!-- 4 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/thr-lever-1-mct">
<default value="0"/>
<test logic="AND" value="1">
/engines/engine[0]/n2-actual ge 59.4
<test logic="OR">
fadec/control-1/detent eq 2
fadec/control-1/detent eq 3
fadec/control-1/detent eq 4
</test>
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/thr-lever-1-mct-output">
<input>/ECAM/warnings/logic/eng/thr-lever-1-mct</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.25</rate_limit> <!-- 4 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/thr-lever-2-mcl-mct">
<default value="0"/>
<test logic="AND" value="1">
/engines/engine[1]/n2-actual ge 59.4
<test logic="OR">
fadec/control-2/detent eq 2
fadec/control-2/detent eq 3
</test>
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/thr-lever-2-mcl-mct-output">
<input>/ECAM/warnings/logic/eng/thr-lever-2-mcl-mct</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.25</rate_limit> <!-- 4 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/thr-lever-2-mct">
<default value="0"/>
<test logic="AND" value="1">
/engines/engine[1]/n2-actual ge 59.4
<test logic="OR">
fadec/control-2/detent eq 2
fadec/control-2/detent eq 3
fadec/control-2/detent eq 4
</test>
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/thr-lever-2-mct-output">
<input>/ECAM/warnings/logic/eng/thr-lever-2-mct</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.25</rate_limit> <!-- 4 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/thr-lever-not-set">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/eng/new-retard-logic ne 1
<test logic="OR">
<test logic="AND">
fadec/limit/flex-active eq 0
<test logic="OR">
/ECAM/warnings/logic/eng/thr-lever-2-mct-output eq 1
/ECAM/warnings/logic/eng/thr-lever-2-mcl-mct-output eq 1
</test>
</test>
<test logic="AND">
fadec/limit/flex-active eq 1
/ECAM/warnings/logic/eng/thr-lever-2-mcl-mct-output eq 1
</test>
<test logic="AND">
fadec/limit/flex-active eq 0
<test logic="OR">
/ECAM/warnings/logic/eng/thr-lever-1-mct-output eq 1
/ECAM/warnings/logic/eng/thr-lever-1-mcl-mct-output eq 1
</test>
</test>
<test logic="AND">
fadec/limit/flex-active eq 1
/ECAM/warnings/logic/eng/thr-lever-1-mcl-mct-output eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/reverse-set">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/timer/ground-calc eq 0
<test logic="OR">
/gear/gear[1]/rollspeed-ms lt 36
/ECAM/warning-phase ne 7
</test>
<test logic="OR">
/controls/engines/engine[0]/reverse-lever gt 0.0
/controls/engines/engine[1]/reverse-lever gt 0.0
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-1-fail-cond-set-input">
<default value="0"/>
<test logic="OR" value="1">
/engines/engine[0]/n2-actual ge 59.4
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/eng-1-fail-cond-set">
<input>/ECAM/warnings/logic/eng/eng-1-fail-cond-set-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.3333</rate_limit> <!-- 3 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/eng-1-fail-cond-reset">
<default value="0"/>
<test logic="OR" value="1">
/controls/engines/engine[0]/cutoff-switch eq 1
/controls/engines/engine[0]/fire-btn eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-2-fail-cond-set-input">
<default value="0"/>
<test logic="OR" value="1">
/engines/engine[1]/n2-actual ge 59.4
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/eng-2-fail-cond-set">
<input>/ECAM/warnings/logic/eng/eng-2-fail-cond-set-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.3333</rate_limit> <!-- 3 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/eng-2-fail-cond-reset">
<default value="0"/>
<test logic="OR" value="1">
/controls/engines/engine[1]/cutoff-switch eq 1
/controls/engines/engine[1]/fire-btn eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-1-fail-set">
<default value="0"/>
<test logic="AND" value="1">
/controls/engines/engine[0]/cutoff-switch eq 0
/controls/engines/engine[0]/fire-btn eq 0
/engines/engine[0]/n2-actual lt 59.39
/ECAM/warnings/logic/eng/eng-1-fail-cond eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-2-fail-set">
<default value="0"/>
<test logic="AND" value="1">
/controls/engines/engine[1]/cutoff-switch eq 0
/controls/engines/engine[1]/fire-btn eq 0
/engines/engine[1]/n2-actual lt 59.39
/ECAM/warnings/logic/eng/eng-2-fail-cond eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-1-fail-reset">
<default value="0"/>
<test logic="OR" value="1">
/engines/engine[0]/n2-actual ge 59.4
/ECAM/dual-failure-enabled eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-2-fail-reset">
<default value="0"/>
<test logic="OR" value="1">
/engines/engine[1]/n2-actual ge 59.4
/ECAM/dual-failure-enabled eq 1
</test>
</switch>
<actuator name="/ECAM/warnings/logic/eng/eng-1-master-60-sec">
<input>/controls/engines/engine[0]/cutoff-switch</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.01666666666</rate_limit> <!-- 60 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/eng/eng-2-master-60-sec">
<input>/controls/engines/engine[1]/cutoff-switch</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.01666666666</rate_limit> <!-- 60 seconds -->
</actuator>
<switch name="/ECAM/warnings/logic/eng/phase-5">
<default value="0"/>
<test logic="AND" value="1">
<test logic="AND">
/ECAM/warnings/logic/stall/phase-4-output eq 0
/ECAM/warnings/logic/stall/phase-4 eq 0
/ECAM/warning-phase eq 5
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-1-fail">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/ECAM/warnings/logic/eng/phase-5-output eq 1
/ECAM/warnings/logic/eng/phase-5-output-2 eq 1
/ECAM/warnings/logic/eng/eng-1-master-60-sec eq 0 <!-- because the sense of cutoff is inverted -->
</test>
/ECAM/warnings/logic/eng/eng-1-fail-output eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-2-fail">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/ECAM/warnings/logic/eng/phase-5-output eq 1
/ECAM/warnings/logic/eng/phase-5-output-2 eq 1
/ECAM/warnings/logic/eng/eng-2-master-60-sec eq 0 <!-- because the sense of cutoff is inverted -->
</test>
/ECAM/warnings/logic/eng/eng-2-fail-output eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-shutdown-phase">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 2
/ECAM/warning-phase eq 9
/ECAM/warning-phase eq 10
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-1-shutdown">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/dual-failure-enabled eq 0
<test logic="OR">
<test logic="AND">
<test logic="OR">
/ECAM/warnings/logic/eng/eng-shutdown-phase eq 1
/ECAM/timer/ground-calc eq 0
</test>
/controls/engines/engine[0]/fire-btn eq 1
</test>
<test logic="AND">
/ECAM/warnings/logic/eng/eng-shutdown-phase eq 0
/controls/engines/engine[0]/cutoff-switch eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng/eng-2-shutdown">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/dual-failure-enabled eq 0
<test logic="OR">
<test logic="AND">
<test logic="OR">
/ECAM/warnings/logic/eng/eng-shutdown-phase eq 1
/ECAM/timer/ground-calc eq 0
</test>
/controls/engines/engine[1]/fire-btn eq 1
</test>
<test logic="AND">
/ECAM/warnings/logic/eng/eng-shutdown-phase eq 0
/controls/engines/engine[1]/cutoff-switch eq 1
</test>
</test>
</test>
</switch>
</channel>
<channel name="Config" execrate="16">
<switch name="/ECAM/warnings/config/park-brk/park-brk-set">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warning-phase eq 3
/controls/gear/brake-parking eq 1
</test>
</switch>
<switch name="/ECAM/warnings/config/park-brk/park-brk-reset">
<default value="0"/>
<test logic="OR" value="1">
/controls/gear/brake-parking eq 0
/ECAM/warning-phase eq 5
</test>
</switch>
</channel>
<channel name="FCTL" execrate="16">
<switch name="/ECAM/warnings/fctl/lrElevFault">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warning-phase ne 1
/ECAM/warning-phase ne 10
<test logic="OR">
hydraulics/elevator-l/pressure-switch-or eq 0
/systems/failures/elevator-left eq 1
</test>
<test logic="OR">
hydraulics/elevator-r/pressure-switch-or eq 0
/systems/failures/elevator-right eq 1
</test>
</test>
</switch>
<actuator name="/ECAM/warnings/fctl/lrElevFault-output">
<input>/ECAM/warnings/fctl/lrElevFault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">3.33333333333</rate_limit> <!-- 0.3 seconds -->
</actuator>
<switch name="/ECAM/warnings/fctl/leftElevFault-cond">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
<test logic="AND">
/systems/fctl/elac1 eq 0
/systems/fctl/sec1 eq 0
</test>
/systems/hydraulic/blue-psi lt 1500
</test>
<test logic="OR">
<test logic="AND">
/systems/fctl/elac2 eq 0
/systems/fctl/sec2 eq 0
</test>
/systems/hydraulic/green-psi lt 1500
</test>
</test>
</switch>
<switch name="/ECAM/warnings/fctl/leftElevFault">
<default value="0"/>
<test logic="AND" value="1">
/systems/hydraulic/blue-psi ge 1500
/systems/hydraulic/green-psi ge 1500
/systems/electrical/bus/dc-2 ge 25
/ECAM/warnings/fctl/lrElevFault ne 1
<test logic="OR">
/controls/fctl/switches/elac1 eq 1
/controls/fctl/switches/elac2 eq 1
/controls/fctl/switches/sec1 eq 1
/controls/fctl/switches/sec2 eq 1
</test>
/ECAM/warnings/fctl/leftElevFault-cond eq 1
</test>
</switch>
<actuator name="/ECAM/warnings/fctl/leftElevFault-output">
<input>/ECAM/warnings/fctl/leftElevFault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">3.33333333333</rate_limit> <!-- 0.3 seconds -->
</actuator>
<switch name="/ECAM/warnings/fctl/rightElevFault-cond">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
<test logic="AND">
/systems/fctl/elac1 eq 0
/systems/fctl/sec1 eq 0
</test>
/systems/hydraulic/blue-psi lt 1500
</test>
<test logic="OR">
<test logic="AND">
/systems/fctl/elac2 eq 0
/systems/fctl/sec2 eq 0
</test>
/systems/hydraulic/yellow-psi lt 1500
</test>
</test>
</switch>
<switch name="/ECAM/warnings/fctl/rightElevFault">
<default value="0"/>
<test logic="AND" value="1">
/systems/hydraulic/blue-psi ge 1500
/systems/hydraulic/yellow-psi ge 1500
/systems/electrical/bus/dc-2 ge 25
/ECAM/warnings/fctl/lrElevFault ne 1
<test logic="OR">
/controls/fctl/switches/elac1 eq 1
/controls/fctl/switches/elac2 eq 1
/controls/fctl/switches/sec1 eq 1
/controls/fctl/switches/sec2 eq 1
</test>
/ECAM/warnings/fctl/rightElevFault-cond eq 1
</test>
</switch>
<actuator name="/ECAM/warnings/fctl/rightElevFault-output">
<input>/ECAM/warnings/fctl/rightElevFault</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">3.33333333333</rate_limit> <!-- 0.3 seconds -->
</actuator>
<switch name="/ECAM/warnings/fctl/altn-law">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warning-phase ne 1
/ECAM/warning-phase ne 10
/it-fbw/law eq 1
</test>
</switch>
<actuator name="/ECAM/warnings/fctl/altn-law-output">
<input>/ECAM/warnings/fctl/altn-law</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">3.33333333333</rate_limit> <!-- 0.3 seconds -->
</actuator>
<switch name="/ECAM/warnings/fctl/direct-law-output">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warning-phase ne 1
/ECAM/warning-phase ne 10
/it-fbw/law eq 2
</test>
</switch>
<switch name="/ECAM/warnings/fctl/gear-not-down-not-cancellable">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/instrumentation/radar-altimeter[0]/radar-altitude-ft-corrected lt 750
/instrumentation/radar-altimeter[1]/radar-altitude-ft-corrected lt 750
</test>
/ECAM/phases/phase-calculation/takeoff-power eq 0
<test logic="OR">
fcs/slat-pos-deg gt 16
fcs/flap-pos-deg gt 18
</test>
<test logic="OR">
/gear/gear[0]/position-norm ne 1
/gear/gear[1]/position-norm ne 1
/gear/gear[2]/position-norm ne 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/fctl/gear-not-down-cancellable">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/fctl/gear-not-down-not-cancellable ne 1
/instrumentation/altimeter[0]/indicated-altitude-ft lt 18500
<test logic="OR">
<test logic="AND">
/engines/engine[0]/n1-actual lt 75
/engines/engine[1]/n1-actual lt 75
</test>
<test logic="AND">
/engines/engine[0]/n1-actual lt 97
/controls/engines/engine[1]/cutoff-switch eq 1
</test>
<test logic="AND">
/engines/engine[1]/n1-actual lt 97
/controls/engines/engine[0]/cutoff-switch eq 1
</test>
</test>
<test logic="OR">
/instrumentation/radar-altimeter[0]/radar-altitude-ft-corrected lt 750
/instrumentation/radar-altimeter[1]/radar-altitude-ft-corrected lt 750
</test>
/ECAM/phases/phase-calculation/takeoff-power eq 0
<test logic="OR">
/gear/gear[0]/position-norm ne 1
/gear/gear[1]/position-norm ne 1
/gear/gear[2]/position-norm ne 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/fctl/gear-lever-down">
<default value="0"/>
<test logic="AND" value="1">
/controls/gear/gear-down eq 1
<test logic="OR">
/ECAM/warning-phase eq 6
/ECAM/warning-phase eq 7
</test>
</test>
</switch>
<switch name="/ECAM/warnings/fctl/gear-not-downlocked-set">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/fctl/gear-lever-down-pulse eq 1
/ECAM/warnings/fctl/gear-lever-down eq 1
/ECAM/warnings/fctl/gear-not-down-locked eq 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/gear-not-downlocked-reset">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warning-phase eq 8
</test>
</switch>
<switch name="/ECAM/warnings/fctl/gear-not-down-locked-set-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/fctl/gear-lever-down eq 1
<test logic="OR">
/gear/gear[0]/position-norm ne 1
/gear/gear[1]/position-norm ne 1
/gear/gear[2]/position-norm ne 1
</test>
</test>
</switch>
<actuator name="/ECAM/warnings/fctl/gear-not-down-locked-set-output">
<input>/ECAM/warnings/fctl/gear-not-down-locked-set-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.03333333333</rate_limit> <!-- 30 seconds -->
</actuator>
<switch name="/ECAM/warnings/fctl/gear-not-down-locked-set">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/fctl/gear-not-down-locked-set-output eq 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/gear-not-down-locked-reset">
<default value="0"/>
<test logic="AND" value="1">
/gear/gear[0]/position-norm eq 1
/gear/gear[1]/position-norm eq 1
/gear/gear[2]/position-norm eq 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/flaps-not-zero">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warning-phase eq 6
/controls/flight/flaps-input ne 0
<test logic="OR">
/systems/navigation/adr/computation/baro-alt-corrected-1-capt ge 22000
/systems/navigation/adr/computation/baro-alt-corrected-2-capt ge 22000
/systems/navigation/adr/computation/baro-alt-corrected-3-capt ge 22000
</test>
</test>
</switch>
<switch name="/ECAM/warnings/fctl/flaps-config-range">
<default value="0"/>
<test logic="OR" value="1">
fcs/flap-pos-deg lt 2
fcs/flap-pos-deg ge 24
</test>
</switch>
<switch name="/ECAM/warnings/fctl/flaps-config-set">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/ECAM/warning-phase eq 3
/ECAM/warning-phase eq 4
</test>
/ECAM/warnings/fctl/flaps-config-range eq 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/flaps-config-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 5
/ECAM/warnings/fctl/flaps-config-range ne 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/slats-config-range">
<default value="0"/>
<test logic="OR" value="1">
fcs/slat-pos-deg lt 17
fcs/slat-pos-deg ge 25
</test>
</switch>
<switch name="/ECAM/warnings/fctl/slats-config-set">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/ECAM/warning-phase eq 3
/ECAM/warning-phase eq 4
</test>
/ECAM/warnings/fctl/slats-config-range eq 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/slats-config-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 5
/ECAM/warnings/fctl/slats-config-range ne 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/spd-brk-config-range">
<default value="0"/>
<test logic="OR" value="1">
/controls/flight/speedbrake gt 0.0
</test>
</switch>
<switch name="/ECAM/warnings/fctl/spd-brk-config-set">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/ECAM/warning-phase eq 3
/ECAM/warning-phase eq 4
</test>
/ECAM/warnings/fctl/spd-brk-config-range eq 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/spd-brk-config-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 5
/ECAM/warnings/fctl/spd-brk-config-range ne 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/pitch-trim-config-range">
<default value="0"/>
<test logic="OR" value="1">
hydraulics/stabilizer/final-deg gt 2.9
hydraulics/stabilizer/final-deg lt -2.9
</test>
</switch>
<switch name="/ECAM/warnings/fctl/pitch-trim-config-set">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/ECAM/warning-phase eq 3
/ECAM/warning-phase eq 4
</test>
/ECAM/warnings/fctl/pitch-trim-config-range eq 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/pitch-trim-config-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 5
/ECAM/warnings/fctl/pitch-trim-config-range ne 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/rudder-trim-config-range">
<default value="0"/>
<test logic="OR" value="1">
hydraulics/rudder/trim-deg gt 3.6
hydraulics/rudder/trim-deg lt -3.6
</test>
</switch>
<switch name="/ECAM/warnings/fctl/rudder-trim-config-set">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/ECAM/warning-phase eq 3
/ECAM/warning-phase eq 4
</test>
/ECAM/warnings/fctl/rudder-trim-config-range eq 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/rudder-trim-config-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 5
/ECAM/warnings/fctl/rudder-trim-config-range ne 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/park-brk-config-set">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warning-phase eq 3
/controls/gear/brake-parking eq 1
</test>
</switch>
<switch name="/ECAM/warnings/fctl/park-brk-config-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 5
/controls/gear/brake-parking eq 0
</test>
</switch>
<switch name="/ECAM/warnings/fctl/spd-brk-still-out-50-seconds-input">
<default value="0"/>
<test logic="AND" value="1">
/controls/flight/speedbrake gt 0.0
</test>
</switch>
<actuator name="/ECAM/warnings/fctl/spd-brk-still-out-50-seconds">
<input>/ECAM/warnings/fctl/spd-brk-still-out-50-seconds-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.02</rate_limit> <!-- 50 seconds -->
</actuator>
<switch name="/ECAM/warnings/fctl/spd-brk-still-out-10-seconds-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/fctl/spd-brk-still-out-50-seconds eq 1
fadec/both-at-idle eq 1
</test>
</switch>
<actuator name="/ECAM/warnings/fctl/spd-brk-still-out-10-seconds">
<input>/ECAM/warnings/fctl/spd-brk-still-out-10-seconds-input</input>
<rate_limit sense="incr">120</rate_limit> <!-- Instant -->
<rate_limit sense="decr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<switch name="/ECAM/warnings/fctl/spd-brk-still-out-1-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warning-phase eq 6
/ECAM/warnings/fctl/spd-brk-still-out-50-seconds eq 1
/ECAM/warnings/fctl/spd-brk-still-out-10-seconds eq 0
</test>
</switch>
<actuator name="/ECAM/warnings/fctl/spd-brk-still-out-1">
<input>/ECAM/warnings/fctl/spd-brk-still-out-1-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.03333333333</rate_limit> <!-- 30 seconds -->
</actuator>
<switch name="/ECAM/warnings/fctl/spd-brk-still-out-2-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warning-phase eq 7
/controls/flight/speedbrake gt 0.0
</test>
</switch>
<actuator name="/ECAM/warnings/fctl/spd-brk-still-out-2">
<input>/ECAM/warnings/fctl/spd-brk-still-out-2-input</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<!-- TCAS ON AP
<switch name="/ECAM/warnings/fctl/spd-brk-still-out-3-input">
<default value="0"/>
<test logic="OR" value="1">
/controls/flight/speedbrake gt 0.0
</test>
</switch>-->
<!--<actuator name="/ECAM/warnings/fctl/spd-brk-still-out-3">
<input>/ECAM/warnings/fctl/spd-brk-still-out-3-input</input>
<rate_limit sense="decr">120</rate_limit>--> <!-- Instant -->
<!--<rate_limit sense="incr">0.2</rate_limit>--> <!-- 5 seconds -->
<!--</actuator>-->
<switch name="/ECAM/warnings/fctl/spd-brk-still-out">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/fctl/spd-brk-still-out-1 eq 1
/ECAM/warnings/fctl/spd-brk-still-out-2 eq 1
<!--/ECAM/warnings/fctl/spd-brk-still-out-3 eq 1-->
</test>
</switch>
</channel>
<channel name="Hydraulic" execrate="16">
<switch name="/ECAM/warnings/hyd/engines-2-online">
<default value="0"/>
<test logic="AND" value="1">
/engines/engine[0]/state eq 3
/engines/engine[1]/state eq 3
</test>
</switch>
<actuator name="/ECAM/warnings/hyd/engines-2-online-output">
<input>/ECAM/warnings/hyd/engines-2-online</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit>
</actuator>
<switch name="/ECAM/warnings/hyd/engines-2-off-in-air">
<default value="0"/>
<test logic="AND" value="1">
/engines/engine[0]/state ne 3
/engines/engine[1]/state ne 3
/ECAM/timer/ground-calc eq 0
</test>
</switch>
<actuator name="/ECAM/warnings/hyd/engines-2-off-in-air-output">
<input>/ECAM/warnings/hyd/engines-2-off-in-air</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<switch name="/ECAM/warnings/hyd/engine-1-start">
<default value="0"/>
<test logic="OR" value="1">
/engines/engine[0]/state eq 3
<test logic="AND">
/ECAM/warning-phase ne 1
/ECAM/warning-phase ne 2
/ECAM/warning-phase ne 9
/ECAM/warning-phase ne 10
</test>
</test>
</switch>
<actuator name="/ECAM/warnings/hyd/engine-1-start-output">
<input>/ECAM/warnings/hyd/engine-1-start</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit>
</actuator>
<switch name="/ECAM/warnings/hyd/engine-2-start">
<default value="0"/>
<test logic="AND" value="1">
/engines/engine[1]/state eq 3
<test logic="AND">
/ECAM/warning-phase ne 1
/ECAM/warning-phase ne 2
/ECAM/warning-phase ne 9
/ECAM/warning-phase ne 10
</test>
</test>
</switch>
<actuator name="/ECAM/warnings/hyd/engine-2-start-output">
<input>/ECAM/warnings/hyd/engine-2-start</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit>
</actuator>
<switch name="/ECAM/warnings/hyd/blue-abnorm-lo-pr">
<default value="0"/>
<test logic="AND" value="1">
/systems/hydraulic/warnings/blue-lo-pr eq 1
<test logic="OR">
/ECAM/warnings/hyd/engines-2-online eq 1
/ECAM/warnings/hyd/engines-2-off-in-air-output eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/hyd/green-abnorm-lo-pr">
<default value="0"/>
<test logic="AND" value="1">
/systems/hydraulic/warnings/green-lo-pr eq 1
/ECAM/warnings/hyd/engine-1-start-output eq 1
</test>
</switch>
<switch name="/ECAM/warnings/hyd/yellow-abnorm-lo-pr">
<default value="0"/>
<test logic="AND" value="1">
/systems/hydraulic/warnings/yellow-lo-pr eq 1
/ECAM/warnings/hyd/engine-2-start-output eq 1
</test>
</switch>
<switch name="/ECAM/warnings/hyd/blue-dual-failure">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/ECAM/warnings/hyd/blue-abnorm-lo-pr eq 1
/ECAM/warnings/hyd/yellow-abnorm-lo-pr eq 1
</test>
<test logic="AND">
/ECAM/warnings/hyd/blue-abnorm-lo-pr eq 1
/ECAM/warnings/hyd/green-abnorm-lo-pr eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/hyd/green-dual-failure">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/ECAM/warnings/hyd/blue-abnorm-lo-pr eq 1
/ECAM/warnings/hyd/green-abnorm-lo-pr eq 1
</test>
<test logic="AND">
/ECAM/warnings/hyd/yellow-abnorm-lo-pr eq 1
/ECAM/warnings/hyd/green-abnorm-lo-pr eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/hyd/yellow-dual-failure">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/ECAM/warnings/hyd/blue-abnorm-lo-pr eq 1
/ECAM/warnings/hyd/yellow-abnorm-lo-pr eq 1
</test>
<test logic="AND">
/ECAM/warnings/hyd/yellow-abnorm-lo-pr eq 1
/ECAM/warnings/hyd/green-abnorm-lo-pr eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/hyd/blue-green-failure">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
<test logic="AND"> <!-- inhibit unless engine running -->
<test logic="OR">
/ECAM/warning-phase le 2
/ECAM/warning-phase ge 9
</test>
/engines/engine[0]/state eq 3
</test>
<test logic="AND">
/ECAM/warning-phase gt 2
/ECAM/warning-phase lt 9
/ECAM/warning-phase ne 4
/ECAM/warning-phase ne 5
</test>
</test>
/ECAM/warnings/hyd/blue-abnorm-lo-pr eq 1
/ECAM/warnings/hyd/green-abnorm-lo-pr eq 1
</test>
</switch>
<switch name="/ECAM/warnings/hyd/blue-yellow-failure">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
<test logic="AND"> <!-- inhibit unless engine running -->
<test logic="OR">
/ECAM/warning-phase le 2
/ECAM/warning-phase ge 9
</test>
/engines/engine[1]/state eq 3
</test>
<test logic="AND">
/ECAM/warning-phase gt 2
/ECAM/warning-phase lt 9
/ECAM/warning-phase ne 4
/ECAM/warning-phase ne 5
</test>
</test>
/ECAM/warnings/hyd/blue-abnorm-lo-pr eq 1
/ECAM/warnings/hyd/yellow-abnorm-lo-pr eq 1
</test>
</switch>
<switch name="/ECAM/warnings/hyd/green-yellow-failure">
<default value="0"/>
<test logic="AND" value="1">
/engines/engine[0]/state eq 3
/engines/engine[1]/state eq 3
/ECAM/warnings/hyd/green-abnorm-lo-pr eq 1
/ECAM/warnings/hyd/yellow-abnorm-lo-pr eq 1
</test>
</switch>
<switch name="/ECAM/warnings/hyd/blue-green-fuel-consumpt">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/timer/ground-calc eq 0
/engines/engine[0]/state eq 3
/engines/engine[1]/state eq 3
</test>
</switch>
<switch name="/ECAM/warnings/hyd/blue-yellow-fuel-consumpt">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/timer/ground-calc eq 0
/engines/engine[0]/state eq 3
/engines/engine[1]/state eq 3
<test logic="OR">
<test logic="AND">
/ECAM/warnings/logic/SFLAPEXT eq 1
/systems/electrical/bus/dc-ess lt 25
</test>
hydraulics/spoiler-l2/final-deg gt 0.01
hydraulics/spoiler-r2/final-deg gt 0.01
hydraulics/spoiler-l3/final-deg gt 0.01
hydraulics/spoiler-r3/final-deg gt 0.01
hydraulics/spoiler-l4/final-deg gt 0.01
hydraulics/spoiler-r4/final-deg gt 0.01
<test logic="OR">
/systems/fctl/elac1 eq 0
/systems/fctl/elac2 eq 0
/systems/hydraulic/green-psi lt 1500
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/hyd/green-yellow-fuel-consumpt">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/timer/ground-calc eq 0
/engines/engine[0]/state eq 3
/engines/engine[1]/state eq 3
<test logic="OR">
<test logic="AND">
/ECAM/warnings/logic/SFLAPEXT eq 1
/systems/electrical/bus/dc-ess lt 25
</test>
hydraulics/spoiler-l1/final-deg gt 0.01
hydraulics/spoiler-r1/final-deg gt 0.01
hydraulics/spoiler-l2/final-deg gt 0.01
hydraulics/spoiler-r2/final-deg gt 0.01
hydraulics/spoiler-l4/final-deg gt 0.01
hydraulics/spoiler-r4/final-deg gt 0.01
hydraulics/spoiler-l5/final-deg gt 0.01
hydraulics/spoiler-r5/final-deg gt 0.01
<test logic="AND">
<test logic="OR">
/systems/fctl/elac1 eq 0
/systems/fctl/elac2 eq 0
/systems/hydraulic/blue-psi lt 1500
</test>
/ECAM/warnings/logic/BLUE-EMER-ELEC ne 1
</test>
</test>
</test>
</switch>
</channel>
<channel name="Altitude Alerter" execrate="16">
<switch name="/ECAM/warnings/altitude-alert/altInhibit">
<default value="0"/>
<test logic="OR" value="1">
/it-autoflight/input/alt-is-changing eq 1
<test logic="OR">
<test logic="AND">
/gear/gear[1]/position-norm ge 0.99
/gear/gear[2]/position-norm ge 0.99
</test>
<test logic="AND">
/controls/gear/gear-down eq 1
fcs/slat-pos-deg ge 4
</test>
</test>
/it-autoflight/output/lat eq 4
/it-autoflight/output/vert eq 2
/it-autoflight/output/vert eq 6
<!-- /it-autoflight/output/vert eq 7 check -->
</test>
</switch>
<fcs_function name="/ECAM/warnings/altitude-alert/altitude-difference">
<function>
<ifthen>
<not><property>/instrumentation/altimeter[0]/std</property></not>
<abs>
<difference>
<property>/systems/navigation/adr/output/baro-alt-corrected-1-capt</property>
<property>/it-autoflight/input/alt</property>
</difference>
</abs>
<abs>
<difference>
<property>/systems/navigation/adr/output/baro-alt-1-capt</property>
<property>/it-autoflight/input/alt</property>
</difference>
</abs>
</ifthen>
</function>
</fcs_function>
<switch name="/ECAM/warnings/altitude-alert/alt200">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/altitude-alert/altitude-difference le 200
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/alt750">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/altitude-alert/altitude-difference le 750
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/big-3-1-off">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/altitude-alert/altInhibit eq 0
/ECAM/warnings/altitude-alert/alt200 eq 1
/ECAM/warnings/altitude-alert/alt750 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/big-3-2-off">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/altitude-alert/altInhibit eq 0
/ECAM/warnings/altitude-alert/alt200 eq 0
/ECAM/warnings/altitude-alert/alt750 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/big-3-all-off">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/altitude-alert/altInhibit eq 0
/ECAM/warnings/altitude-alert/alt200 eq 0
/ECAM/warnings/altitude-alert/alt750 eq 0
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/flipflop-1-set">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/altitude-alert/big-3-1-off eq 1
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/flipflop-1-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/altitude-alert/big-3-all-off eq 1
/ECAM/warnings/altitude-alert/flipflop-2-reset eq 1
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/flipflop-2-set">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/altitude-alert/big-3-2-off eq 1
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/flipflop-2-reset">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/ECAM/warnings/altitude-alert/gear-downlocked-set eq 1
/ECAM/warnings/altitude-alert/gear-downlocked-output eq 1
</test>
/ECAM/warnings/altitude-alert/alt-is-changing eq 1
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/flipflop-or-1">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/altitude-alert/big-3-2-off eq 1
/ECAM/warnings/altitude-alert/flipflop-1 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/flipflop-or-2">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/altitude-alert/big-3-all-off eq 1
/ECAM/warnings/altitude-alert/flipflop-2 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/flipflop-or">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/altitude-alert/flipflop-or-1 eq 1
/ECAM/warnings/altitude-alert/flipflop-or-2 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/monostable-autopilot">
<default value="0"/>
<test logic="AND" value="1">
/it-autoflight/output/ap1 eq 0
/it-autoflight/output/ap2 eq 0
/ECAM/warnings/altitude-alert/big-3-2-off eq 1
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/c-chord">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/timer/ground-calc ne 1
<test logic="OR">
<test logic="AND">
/ECAM/warnings/altitude-alert/monostable-autopilot eq 1
/ECAM/warnings/altitude-alert/monostable-autopilot-output eq 1
</test>
/ECAM/warnings/altitude-alert/flipflop-or eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/altitude-alert-steady">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/timer/ground-calc ne 1
/ECAM/warnings/altitude-alert/big-3-2-off eq 1
/ECAM/warnings/altitude-alert/flipflop-or-1 eq 0
</test>
</switch>
<switch name="/ECAM/warnings/altitude-alert/altitude-alert-flash">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/timer/ground-calc ne 1
/ECAM/warnings/altitude-alert/flipflop-or eq 1
</test>
</switch>
</channel>
<channel name="FUEL" execrate="16">
<switch name="/ECAM/warnings/fuel/center-pumps-off">
<default value="0"/>
<test logic="AND" value="1">
/controls/fuel/switches/pump-center-1 eq 0
/controls/fuel/switches/pump-center-2 eq 0
/controls/fuel/switches/center-mode eq 1
/systems/fuel/quantity/center-low eq 0
/ECAM/warning-phase eq 6
<!-- TODO NOT DUAL CENTER PUMP FAULT -->
</test>
</switch>
<actuator name="/ECAM/warnings/fuel/center-pumps-off-output">
<input>/ECAM/warnings/fuel/center-pumps-off</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<switch name="/ECAM/warnings/fuel/lo-level-l-r">
<default value="0"/>
<test logic="AND" value="1">
/systems/fuel/quantity/left-wing-inner-low eq 1
/systems/fuel/quantity/right-wing-inner-low eq 1
</test>
</switch>
<actuator name="/ECAM/warnings/fuel/lo-level-l-r-output">
<input>/ECAM/warnings/fuel/lo-level-l-r</input>
<rate_limit sense="decr">120</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.03333333333</rate_limit> <!-- 30 seconds -->
</actuator>
</channel>
<!--<channel name="NAV" execrate="16">
<switch name="/ECAM/warnings/navigation/ADR123-fault">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/bus/ac-1 ge 110
/systems/electrical/bus/ac-2 ge 110
/systems/electrical/bus/ac-ess ge 110
/ECAM/warning-phase ne 1
/ECAM/warning-phase ne 4
/ECAM/warning-phase ne 8
/ECAM/warning-phase ne 10
</test>
</switch>
</channel>-->
</system>