1956 lines
66 KiB
XML
1956 lines
66 KiB
XML
<?xml version="1.0"?>
|
|
|
|
<!-- Copyright (c) 2019 Jonathan Redpath (legoboyvdlp), Joshua Davidson (Octal450) -->
|
|
|
|
<system name="A320: Electrical">
|
|
|
|
<property value="0">/systems/electrical/some-electric-thingie/rat-deploy</property>
|
|
<property value="0">/systems/electrical/relay/gen-1-glc/contact-pos</property>
|
|
<property value="0">/systems/electrical/relay/gen-2-glc/contact-pos</property>
|
|
|
|
<channel name="Main Electrical" execrate="8">
|
|
|
|
<!-- Battery 1 -->
|
|
<fcs_function name="/systems/electrical/sources/bat-1/volt">
|
|
<function>
|
|
<product>
|
|
<difference>
|
|
<value>1</value>
|
|
<product>
|
|
<property>/systems/electrical/sources/bat-1/amps</property>
|
|
<value>0.00016666</value>
|
|
</product>
|
|
</difference>
|
|
<table>
|
|
<independentVar lookup="row">/systems/electrical/sources/bat-1/percent</independentVar>
|
|
<independentVar lookup="column">/systems/failures/electrical/bat-1</independentVar>
|
|
<tableData>
|
|
0 1
|
|
0 0.0 0.0
|
|
10 24.0 4.0
|
|
50 25.5 5.0
|
|
100 31.0 7.0
|
|
</tableData>
|
|
</table>
|
|
</product>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<switch name="/systems/electrical/sources/bat-1/contact">
|
|
<default value="/systems/electrical/sources/bat-1/contact"/>
|
|
<test logic="OR" value="0"> <!-- discharge protection or switch turned off -->
|
|
/controls/electrical/switches/bat-1 eq 0
|
|
/systems/electrical/sources/bat-1/volt lt 23
|
|
/systems/electrical/sources/bat-1/amps ge 100
|
|
</test>
|
|
<test logic="AND" value="1"> <!-- apu start -->
|
|
/controls/electrical/switches/bat-1 eq 1
|
|
/systems/apu/start eq 1
|
|
</test>
|
|
<test logic="AND" value="1"> <!-- connect to dc-bat while no other power on the ground -->
|
|
/controls/electrical/switches/bat-1 eq 1
|
|
/systems/electrical/bus/ac-1 lt 110
|
|
/systems/electrical/bus/ac-2 lt 110
|
|
/gear/gear[1]/wow eq 1
|
|
/instrumentation/airspeed-indicator/indicated-speed-kt lt 100
|
|
</test>
|
|
<test logic="AND" value="1"> <!-- start charging cycle -->
|
|
/systems/electrical/sources/bat-1/charge eq 1
|
|
</test>
|
|
<test logic="AND" value="1"> <!-- maintain charging cycle -->
|
|
/systems/electrical/sources/bat-1/charge eq 1
|
|
/controls/electrical/switches/bat-1 eq 1
|
|
/systems/electrical/sources/bat-1/contact eq 1
|
|
/systems/electrical/bus/dc-bat gt 27.5
|
|
/systems/electrical/sources/bat-1/percent-calc lt 99.9
|
|
</test>
|
|
<test logic="AND" value="0">
|
|
/systems/electrical/sources/bat-1/charge eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/bat-1/charge">
|
|
<default value="/systems/electrical/sources/bat-1/charge"/>
|
|
<test logic="AND" value="0"> <!-- end charging cycle -->
|
|
/systems/electrical/sources/bat-1/charge eq 1
|
|
<test logic="OR">
|
|
/controls/electrical/switches/bat-1 eq 0
|
|
/systems/electrical/bus/dc-bat lt 27.5
|
|
/systems/electrical/sources/bat-1/percent-calc ge 99.9
|
|
</test>
|
|
</test>
|
|
<test logic="AND" value="1"> <!-- start charging cycle -->
|
|
/controls/electrical/switches/bat-1 eq 1
|
|
/systems/electrical/sources/bat-1/contact eq 0
|
|
/systems/electrical/sources/bat-1/volt lt 26.5
|
|
/systems/electrical/bus/dc-bat gt 27.5
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/bat-1/direction">
|
|
<default value="0"/>
|
|
<test logic="AND" value="0">
|
|
/systems/electrical/sources/bat-1/contact eq 0
|
|
/systems/electrical/sources/si-1/inverter-active eq 0
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/sources/si-1/inverter-active eq 1
|
|
</test>
|
|
<test logic="AND" value="1"> <!-- drain -->
|
|
/systems/electrical/sources/bat-1/contact eq 1
|
|
<test logic="OR">
|
|
<test logic="AND">
|
|
/systems/electrical/bus/dc-bat-src ne 1
|
|
/systems/electrical/bus/dc-bat-src ne 2
|
|
</test>
|
|
/systems/apu/start eq 1
|
|
</test>
|
|
</test>
|
|
<test logic="AND" value="-1"> <!-- charge -->
|
|
/systems/electrical/sources/bat-1/contact eq 1
|
|
/systems/electrical/bus/dc-bat-src ne 3
|
|
</test>
|
|
</switch>
|
|
|
|
<fcs_function name="/systems/electrical/sources/bat-1/percent-calc">
|
|
<function>
|
|
<ifthen>
|
|
<eq>
|
|
<property>/systems/electrical/sources/bat-1/direction</property>
|
|
<value>0</value>
|
|
</eq>
|
|
<property>/systems/electrical/sources/bat-1/percent-calc</property>
|
|
<ifthen>
|
|
<eq>
|
|
<property>/systems/electrical/sources/bat-1/direction</property>
|
|
<value>-1</value>
|
|
</eq>
|
|
<sum>
|
|
<property>/systems/electrical/sources/bat-1/percent</property>
|
|
<product>
|
|
<quotient>
|
|
<value>2.25</value>
|
|
<sum>
|
|
<property>/systems/electrical/sources/bat-1/percent</property>
|
|
<value>1</value>
|
|
</sum>
|
|
</quotient>
|
|
<property>simulation/channel-dt</property>
|
|
</product>
|
|
</sum>
|
|
<sum>
|
|
<property>/systems/electrical/sources/bat-1/percent</property>
|
|
<product>
|
|
<quotient>
|
|
<value>-0.75</value>
|
|
<sum>
|
|
<property>/systems/electrical/sources/bat-1/percent</property>
|
|
<value>1</value>
|
|
</sum>
|
|
</quotient>
|
|
<property>simulation/channel-dt</property>
|
|
</product>
|
|
</sum>
|
|
</ifthen>
|
|
</ifthen>
|
|
</function>
|
|
<output>/systems/electrical/sources/bat-1/percent</output>
|
|
</fcs_function>
|
|
|
|
<switch name="/systems/electrical/sources/bat-1/load-kw">
|
|
<default value="0"/>
|
|
<test logic="AND" value="0.864">
|
|
/systems/apu/start eq 1
|
|
/systems/electrical/sources/bat-1/contact eq 1
|
|
</test>
|
|
<test logic="AND" value="1.15"> <!-- 60 amp * 0.8 * 24V = 1.15kw. Guess -->
|
|
/systems/electrical/bus/dc-bat-src ne 1
|
|
/systems/electrical/bus/dc-bat-src ne 2
|
|
/systems/electrical/sources/bat-1/contact eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/bat-1/amps">
|
|
<default value="0"/>
|
|
<test logic="AND" value="40">
|
|
/systems/electrical/sources/bat-1/load-kw ne 0
|
|
/systems/electrical/sources/bat-1/direction eq 1
|
|
</test>
|
|
<test logic="AND" value="2">
|
|
/systems/electrical/sources/bat-1/contact eq 1
|
|
/systems/electrical/sources/bat-1/direction eq -1
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- Battery 2 -->
|
|
<fcs_function name="/systems/electrical/sources/bat-2/volt">
|
|
<function>
|
|
<product>
|
|
<difference>
|
|
<value>1</value>
|
|
<product>
|
|
<property>/systems/electrical/sources/bat-2/amps</property>
|
|
<value>0.00016666</value>
|
|
</product>
|
|
</difference>
|
|
<table>
|
|
<independentVar lookup="row">/systems/electrical/sources/bat-2/percent</independentVar>
|
|
<independentVar lookup="column">/systems/failures/electrical/bat-2</independentVar>
|
|
<tableData>
|
|
0 1
|
|
0 0.0 0.0
|
|
10 24.0 4.0
|
|
50 25.5 5.0
|
|
100 31.0 7.0
|
|
</tableData>
|
|
</table>
|
|
</product>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<switch name="/systems/electrical/sources/bat-2/contact">
|
|
<default value="/systems/electrical/sources/bat-2/contact"/>
|
|
<test logic="OR" value="0"> <!-- discharge protection or switch turned off -->
|
|
/controls/electrical/switches/bat-2 eq 0
|
|
/systems/electrical/sources/bat-2/volt lt 23
|
|
/systems/electrical/sources/bat-2/amps ge 100
|
|
</test>
|
|
<test logic="AND" value="1"> <!-- apu start -->
|
|
/controls/electrical/switches/bat-2 eq 1
|
|
/systems/apu/start eq 1
|
|
</test>
|
|
<test logic="AND" value="1"> <!-- connect to dc-bat while no other power on the ground -->
|
|
/controls/electrical/switches/bat-2 eq 1
|
|
/systems/electrical/bus/ac-1 lt 110
|
|
/systems/electrical/bus/ac-2 lt 110
|
|
/gear/gear[1]/wow eq 1
|
|
/instrumentation/airspeed-indicator/indicated-speed-kt lt 100
|
|
</test>
|
|
<test logic="AND" value="1"> <!-- start charging cycle -->
|
|
/systems/electrical/sources/bat-2/charge eq 1
|
|
</test>
|
|
<test logic="AND" value="1"> <!-- maintain charging cycle -->
|
|
/systems/electrical/sources/bat-2/charge eq 1
|
|
/controls/electrical/switches/bat-2 eq 1
|
|
/systems/electrical/sources/bat-2/contact eq 1
|
|
/systems/electrical/bus/dc-bat gt 27.5
|
|
/systems/electrical/sources/bat-2/percent-calc lt 99.9
|
|
</test>
|
|
<test logic="AND" value="0">
|
|
/systems/electrical/sources/bat-2/charge eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/bat-2/charge">
|
|
<default value="/systems/electrical/sources/bat-2/charge"/>
|
|
<test logic="AND" value="0"> <!-- end charging cycle -->
|
|
/systems/electrical/sources/bat-2/charge eq 1
|
|
<test logic="OR">
|
|
/controls/electrical/switches/bat-2 eq 0
|
|
/systems/electrical/bus/dc-bat lt 27.5
|
|
/systems/electrical/sources/bat-2/percent-calc ge 99.9
|
|
</test>
|
|
</test>
|
|
<test logic="AND" value="1"> <!-- start charging cycle -->
|
|
/controls/electrical/switches/bat-2 eq 1
|
|
/systems/electrical/sources/bat-2/contact eq 0
|
|
/systems/electrical/sources/bat-2/volt lt 26.5
|
|
/systems/electrical/bus/dc-bat gt 27.5
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/bat-2/direction">
|
|
<default value="0"/>
|
|
<test logic="AND" value="0">
|
|
/systems/electrical/sources/bat-2/contact eq 0
|
|
/systems/electrical/sources/si-1/inverter-active eq 0
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/sources/si-1/inverter-active eq 1
|
|
</test>
|
|
<test logic="AND" value="1"> <!-- drain -->
|
|
/systems/electrical/sources/bat-2/contact eq 1
|
|
<test logic="OR">
|
|
<test logic="AND">
|
|
/systems/electrical/bus/dc-bat-src ne 1
|
|
/systems/electrical/bus/dc-bat-src ne 2
|
|
</test>
|
|
/systems/apu/start eq 1
|
|
</test>
|
|
</test>
|
|
<test logic="AND" value="-1"> <!-- charge -->
|
|
/systems/electrical/sources/bat-2/contact eq 1
|
|
/systems/electrical/bus/dc-bat-src ne 3
|
|
</test>
|
|
</switch>
|
|
|
|
<fcs_function name="/systems/electrical/sources/bat-2/percent-calc">
|
|
<function>
|
|
<ifthen>
|
|
<eq>
|
|
<property>/systems/electrical/sources/bat-2/direction</property>
|
|
<value>0</value>
|
|
</eq>
|
|
<property>/systems/electrical/sources/bat-2/percent-calc</property>
|
|
<ifthen>
|
|
<eq>
|
|
<property>/systems/electrical/sources/bat-2/direction</property>
|
|
<value>-1</value>
|
|
</eq>
|
|
<sum>
|
|
<property>/systems/electrical/sources/bat-2/percent</property>
|
|
<product>
|
|
<quotient>
|
|
<value>2.25</value>
|
|
<sum>
|
|
<property>/systems/electrical/sources/bat-2/percent</property>
|
|
<value>1</value>
|
|
</sum>
|
|
</quotient>
|
|
<property>simulation/channel-dt</property>
|
|
</product>
|
|
</sum>
|
|
<sum>
|
|
<property>/systems/electrical/sources/bat-2/percent</property>
|
|
<product>
|
|
<quotient>
|
|
<value>-0.75</value>
|
|
<sum>
|
|
<property>/systems/electrical/sources/bat-2/percent</property>
|
|
<value>1</value>
|
|
</sum>
|
|
</quotient>
|
|
<property>simulation/channel-dt</property>
|
|
</product>
|
|
</sum>
|
|
</ifthen>
|
|
</ifthen>
|
|
</function>
|
|
<output>/systems/electrical/sources/bat-2/percent</output>
|
|
</fcs_function>
|
|
|
|
<switch name="/systems/electrical/sources/bat-2/load-kw">
|
|
<default value="0"/>
|
|
<test logic="AND" value="0.864">
|
|
/systems/apu/start eq 1
|
|
/systems/electrical/sources/bat-2/contact eq 1
|
|
</test>
|
|
<test logic="AND" value="1.15"> <!-- 60 amp * 0.8 * 24V = 1.15kw. Guess -->
|
|
/systems/electrical/bus/dc-bat-src ne 1
|
|
/systems/electrical/bus/dc-bat-src ne 2
|
|
/systems/electrical/sources/bat-2/contact eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/bat-2/amps">
|
|
<default value="0"/>
|
|
<test logic="AND" value="40">
|
|
/systems/electrical/sources/bat-2/load-kw ne 0
|
|
/systems/electrical/sources/bat-2/direction eq 1
|
|
</test>
|
|
<test logic="AND" value="2">
|
|
/systems/electrical/sources/bat-2/contact eq 1
|
|
/systems/electrical/sources/bat-2/direction eq -1
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- IDG 1 -->
|
|
<pure_gain name="/systems/electrical/sources/idg-1/drive-rpm-input">
|
|
<input>/engines/engine[0]/n2-actual</input>
|
|
<gain>90.298</gain> <!-- 1% N2 RPM value * 0.604 -->
|
|
</pure_gain>
|
|
|
|
<switch name="/systems/electrical/sources/idg-1/working">
|
|
<default value="1"/>
|
|
<test logic="OR" value="0">
|
|
/systems/failures/electrical/idg-1 eq 1
|
|
/controls/electrical/switches/idg-1-disc eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<pure_gain name="/systems/electrical/sources/idg-1/drive-rpm">
|
|
<input>/systems/electrical/sources/idg-1/drive-rpm-input</input>
|
|
<gain>/systems/electrical/sources/idg-1/working</gain>
|
|
</pure_gain>
|
|
|
|
<fcs_function name="/systems/electrical/sources/idg-1/csd-gearbox-ratio-cmd">
|
|
<function>
|
|
<quotient>
|
|
<value>12000</value>
|
|
<property>/systems/electrical/sources/idg-1/drive-rpm</property>
|
|
</quotient>
|
|
</function>
|
|
<clipto>
|
|
<min>1.315</min>
|
|
<max>2.667</max>
|
|
</clipto>
|
|
</fcs_function>
|
|
|
|
<lag_filter name="/systems/electrical/sources/idg-1/csd-gearbox-ratio">
|
|
<input>/systems/electrical/sources/idg-1/csd-gearbox-ratio-cmd</input>
|
|
<c1>40</c1>
|
|
</lag_filter>
|
|
|
|
<pure_gain name="/systems/electrical/sources/idg-1/csd-rpm">
|
|
<input>/systems/electrical/sources/idg-1/drive-rpm</input>
|
|
<gain>/systems/electrical/sources/idg-1/csd-gearbox-ratio</gain>
|
|
</pure_gain>
|
|
|
|
<fcs_function name="/systems/electrical/sources/idg-1/pmg-volt">
|
|
<function>
|
|
<product>
|
|
<property>/systems/electrical/sources/idg-1/csd-rpm</property>
|
|
<quotient>
|
|
<value>115</value>
|
|
<value>12000</value>
|
|
</quotient>
|
|
</product>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<fcs_function name="/systems/electrical/sources/idg-1/pmg-hertz">
|
|
<function>
|
|
<quotient>
|
|
<product>
|
|
<property>/systems/electrical/sources/idg-1/csd-rpm</property>
|
|
<value>4</value> <!-- Number of poles in generator -->
|
|
</product>
|
|
<value>120</value>
|
|
</quotient>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<switch name="/systems/electrical/sources/idg-1/gcr-relay">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/failures/electrical/gen-1 ne 1
|
|
/controls/engines/engine[0]/fire-btn eq 0
|
|
/systems/electrical/sources/idg-1/drive-rpm ge 4730
|
|
</test>
|
|
</switch>
|
|
|
|
<pure_gain name="/systems/electrical/sources/idg-1/output-volt">
|
|
<input>/systems/electrical/sources/idg-1/pmg-volt</input>
|
|
<gain>/systems/electrical/sources/idg-1/gcr-relay</gain>
|
|
</pure_gain>
|
|
|
|
<pure_gain name="/systems/electrical/sources/idg-1/output-hertz">
|
|
<input>/systems/electrical/sources/idg-1/pmg-hertz</input>
|
|
<gain>/systems/electrical/sources/idg-1/gcr-relay</gain>
|
|
</pure_gain>
|
|
|
|
<!-- IDG 2 -->
|
|
<pure_gain name="/systems/electrical/sources/idg-2/drive-rpm-input">
|
|
<input>/engines/engine[1]/n2-actual</input>
|
|
<gain>90.298</gain> <!-- 1% N2 RPM value * 0.604 -->
|
|
</pure_gain>
|
|
|
|
<switch name="/systems/electrical/sources/idg-2/working">
|
|
<default value="1"/>
|
|
<test logic="OR" value="0">
|
|
/systems/failures/electrical/idg-2 eq 1
|
|
/controls/electrical/switches/idg-2-disc eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<pure_gain name="/systems/electrical/sources/idg-2/drive-rpm">
|
|
<input>/systems/electrical/sources/idg-2/drive-rpm-input</input>
|
|
<gain>/systems/electrical/sources/idg-2/working</gain>
|
|
</pure_gain>
|
|
|
|
<fcs_function name="/systems/electrical/sources/idg-2/csd-gearbox-ratio-cmd">
|
|
<function>
|
|
<quotient>
|
|
<value>12000</value>
|
|
<property>/systems/electrical/sources/idg-2/drive-rpm</property>
|
|
</quotient>
|
|
</function>
|
|
<clipto>
|
|
<min>1.315</min>
|
|
<max>2.667</max>
|
|
</clipto>
|
|
</fcs_function>
|
|
|
|
<lag_filter name="/systems/electrical/sources/idg-2/csd-gearbox-ratio">
|
|
<input>/systems/electrical/sources/idg-2/csd-gearbox-ratio-cmd</input>
|
|
<c1>40</c1>
|
|
</lag_filter>
|
|
|
|
<pure_gain name="/systems/electrical/sources/idg-2/csd-rpm">
|
|
<input>/systems/electrical/sources/idg-2/drive-rpm</input>
|
|
<gain>/systems/electrical/sources/idg-2/csd-gearbox-ratio</gain>
|
|
</pure_gain>
|
|
|
|
<fcs_function name="/systems/electrical/sources/idg-2/pmg-volt">
|
|
<function>
|
|
<product>
|
|
<property>/systems/electrical/sources/idg-2/csd-rpm</property>
|
|
<quotient>
|
|
<value>115</value>
|
|
<value>12000</value>
|
|
</quotient>
|
|
</product>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<fcs_function name="/systems/electrical/sources/idg-2/pmg-hertz">
|
|
<function>
|
|
<quotient>
|
|
<product>
|
|
<property>/systems/electrical/sources/idg-2/csd-rpm</property>
|
|
<value>4</value> <!-- Number of poles in generator -->
|
|
</product>
|
|
<value>120</value>
|
|
</quotient>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<switch name="/systems/electrical/sources/idg-2/gcr-relay">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/failures/electrical/gen-2 ne 1
|
|
/controls/engines/engine[1]/fire-btn eq 0
|
|
/systems/electrical/sources/idg-2/drive-rpm ge 4730
|
|
</test>
|
|
</switch>
|
|
|
|
<pure_gain name="/systems/electrical/sources/idg-2/output-volt">
|
|
<input>/systems/electrical/sources/idg-2/pmg-volt</input>
|
|
<gain>/systems/electrical/sources/idg-2/gcr-relay</gain>
|
|
</pure_gain>
|
|
|
|
<pure_gain name="/systems/electrical/sources/idg-2/output-hertz">
|
|
<input>/systems/electrical/sources/idg-2/pmg-hertz</input>
|
|
<gain>/systems/electrical/sources/idg-2/gcr-relay</gain>
|
|
</pure_gain>
|
|
|
|
<!-- APU gen -->
|
|
<pure_gain name="/systems/electrical/sources/apu/drive-rpm-input">
|
|
<input>/engines/engine[2]/n1</input>
|
|
<gain>240.34</gain>
|
|
</pure_gain>
|
|
|
|
<switch name="/systems/electrical/sources/apu/working">
|
|
<default value="1"/>
|
|
<test logic="OR" value="0">
|
|
/controls/apu/fire-btn eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<pure_gain name="/systems/electrical/sources/apu/drive-rpm">
|
|
<input>/systems/electrical/sources/apu/drive-rpm-input</input>
|
|
<gain>/systems/electrical/sources/apu/working</gain>
|
|
</pure_gain>
|
|
|
|
<fcs_function name="/systems/electrical/sources/apu/pmg-volt">
|
|
<function>
|
|
<product>
|
|
<property>/systems/electrical/sources/apu/drive-rpm-input</property>
|
|
<quotient>
|
|
<value>115</value>
|
|
<value>24000</value>
|
|
</quotient>
|
|
</product>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<fcs_function name="/systems/electrical/sources/apu/pmg-hertz">
|
|
<function>
|
|
<quotient>
|
|
<product>
|
|
<property>/systems/electrical/sources/apu/drive-rpm-input</property>
|
|
<value>2</value> <!-- Number of poles in generator -->
|
|
</product>
|
|
<value>120</value>
|
|
</quotient>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<switch name="/systems/electrical/sources/apu/gcr-relay">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/electrical/switches/apu eq 1
|
|
/systems/failures/electrical/apu ne 1
|
|
/systems/electrical/sources/apu/drive-rpm-input ge 23000
|
|
</test>
|
|
</switch>
|
|
|
|
<pure_gain name="/systems/electrical/sources/apu/output-volt">
|
|
<input>/systems/electrical/sources/apu/pmg-volt</input>
|
|
<gain>/systems/electrical/sources/apu/gcr-relay</gain>
|
|
</pure_gain>
|
|
|
|
<pure_gain name="/systems/electrical/sources/apu/output-hertz">
|
|
<input>/systems/electrical/sources/apu/pmg-hertz</input>
|
|
<gain>/systems/electrical/sources/apu/gcr-relay</gain>
|
|
</pure_gain>
|
|
|
|
<!-- External Power -->
|
|
<fcs_function name="/systems/electrical/sources/ext/output-volt">
|
|
<function>
|
|
<ifthen>
|
|
<eq>
|
|
<property>/controls/electrical/ground-cart</property>
|
|
<value>1</value>
|
|
</eq>
|
|
<value>115</value>
|
|
<value>0</value>
|
|
</ifthen>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<fcs_function name="/systems/electrical/sources/ext/output-hertz">
|
|
<function>
|
|
<ifthen>
|
|
<ge>
|
|
<property>/systems/electrical/sources/ext/output-volt</property>
|
|
<value>110</value>
|
|
</ge>
|
|
<value>400</value>
|
|
<value>0</value>
|
|
</ifthen>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<!-- Static Inverter -->
|
|
<switch name="/systems/electrical/sources/si-1/inverter-active">
|
|
<default value="0"/>
|
|
<test value="0">
|
|
/systems/failures/electrical/stat-inv eq 1
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/some-electric-thingie/emer-gen-operate eq 1
|
|
/systems/electrical/sources/emer-gen/coupled ne 1
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/instrumentation/airspeed-indicator/indicated-speed-kt lt 100
|
|
/instrumentation/airspeed-indicator/indicated-speed-kt ge 50
|
|
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
|
|
/sim/time/elapsed-sec gt 10
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/instrumentation/airspeed-indicator/indicated-speed-kt lt 50
|
|
/controls/electrical/switches/bat-1 eq 1
|
|
/controls/electrical/switches/bat-2 eq 1
|
|
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
|
|
/sim/time/elapsed-sec gt 10
|
|
</test>
|
|
</switch>
|
|
|
|
<fcs_function name="/systems/electrical/sources/si-1/inverter-gain">
|
|
<function>
|
|
<ifthen>
|
|
<eq>
|
|
<property>/systems/electrical/sources/si-1/inverter-active</property>
|
|
<value>1</value>
|
|
</eq>
|
|
<quotient>
|
|
<value>115</value>
|
|
<property>/systems/electrical/sources/bat-1/volt</property>
|
|
</quotient>
|
|
<value>0</value>
|
|
</ifthen>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<pure_gain name="/systems/electrical/sources/si-1/output-volt">
|
|
<input>/systems/electrical/sources/bat-1/volt</input> <!-- inverter feeds directly from batteries -->
|
|
<gain>/systems/electrical/sources/si-1/inverter-gain</gain>
|
|
</pure_gain>
|
|
|
|
<switch name="/systems/electrical/sources/si-1/fault">
|
|
<default value="0"/>
|
|
<test logic="OR" value="1">
|
|
/systems/electrical/sources/bat-1/volt lt 23.5
|
|
/systems/electrical/sources/si-1/output-volt lt 110
|
|
/systems/electrical/sources/si-1/output-volt ge 120
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/si-1/output-hertz">
|
|
<default value="0"/>
|
|
<test logic="AND" value="400">
|
|
/systems/electrical/sources/si-1/output-volt ge 110
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- Emergency Generator -->
|
|
<switch name="/systems/electrical/some-electric-thingie/rat-deploy">
|
|
<default value="/systems/electrical/some-electric-thingie/rat-deploy"/>
|
|
<test logic="AND" value="1">
|
|
/instrumentation/airspeed-indicator/indicated-speed-kt gt 100
|
|
/sim/time/elapsed-sec gt 30
|
|
/systems/electrical/bus/ac-1 eq 0
|
|
/systems/electrical/bus/ac-2 eq 0
|
|
/controls/electrical/switches/emer-elec-man-on eq 0
|
|
</test>
|
|
<test logic="OR" value="1">
|
|
/controls/hydraulic/switches/rat-man eq 1
|
|
/controls/electrical/switches/emer-elec-man-on eq 1
|
|
</test>
|
|
<!--<test value="0">
|
|
/controls/hydraulic/switches/ground-rat-retraction eq 1
|
|
</test>-->
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/some-electric-thingie/emer-gen-operate">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/electrical/switches/emer-gen-test eq 1
|
|
/systems/electrical/bus/ac-1 ne 0
|
|
/systems/electrical/bus/ac-2 ne 0
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/instrumentation/airspeed-indicator/indicated-speed-kt ge 100
|
|
/systems/electrical/bus/ac-1 eq 0
|
|
/systems/electrical/bus/ac-2 eq 0
|
|
gear/unit[0]/WOW eq 0
|
|
/controls/electrical/switches/emer-elec-man-on eq 0
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
gear/unit[0]/WOW eq 0
|
|
/controls/electrical/switches/emer-elec-man-on eq 1
|
|
</test>
|
|
</switch>
|
|
<switch name="/systems/electrical/some-electric-thingie/emer-gen-operating-on-rat">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/some-electric-thingie/emer-gen-operate eq 1
|
|
/systems/hydraulic/sources/rat/position eq 1
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/controls/electrical/switches/emer-gen-test eq 1
|
|
/systems/electrical/bus/ac-1 ne 0
|
|
/systems/electrical/bus/ac-2 ne 0
|
|
</test>
|
|
</switch>
|
|
|
|
<kinematic name="/systems/electrical/sources/emer-gen/coupled-kin">
|
|
<input>/systems/electrical/some-electric-thingie/emer-gen-operating-on-rat</input>
|
|
<traverse>
|
|
<setting>
|
|
<position>0.0</position>
|
|
<time>0.0</time>
|
|
</setting>
|
|
<setting>
|
|
<position>1.0</position>
|
|
<time>5.5</time>
|
|
</setting>
|
|
</traverse>
|
|
</kinematic>
|
|
|
|
<switch name="/systems/electrical/sources/emer-gen/coupled">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/sources/emer-gen/coupled-kin eq 1
|
|
/systems/failures/electrical/emer-gen ne 1
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/controls/electrical/switches/emer-gen-test eq 1
|
|
/systems/failures/electrical/emer-gen ne 1
|
|
/systems/electrical/bus/ac-1 ne 0
|
|
/systems/electrical/bus/ac-2 ne 0
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- Regulated to 115V, no point doing fancy, HYD controls it -->
|
|
<switch name="/systems/electrical/sources/emer-gen/output-volt">
|
|
<default value="0"/>
|
|
<test logic="AND" value="115">
|
|
/systems/electrical/some-electric-thingie/emer-gen-operate eq 1
|
|
/systems/electrical/sources/emer-gen/coupled eq 1
|
|
/systems/hydraulic/blue-psi ge 2500
|
|
/systems/failures/electrical/emer-gen eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/emer-gen/output-hertz">
|
|
<default value="0"/>
|
|
<test logic="AND" value="400">
|
|
/systems/electrical/sources/emer-gen/output-volt ge 110
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- Source Relays -->
|
|
<switch name="/systems/electrical/sources/idg-1/gcu-1-powered">
|
|
<default value="0"/>
|
|
<test logic="OR" value="1">
|
|
/systems/electrical/bus/dc-bat ge 25
|
|
/systems/electrical/sources/idg-1/pmg-volt ge 110
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/idg-1/gcu-1-voltage-trip">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/sources/idg-1/gcu-1-voltage-trip eq 1
|
|
/controls/electrical/switches/gen-1 eq 1
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/relay/gen-1-glc/contact-pos eq 1
|
|
<test logic="OR">
|
|
/systems/electrical/sources/idg-1/output-volt lt 110
|
|
/systems/electrical/sources/idg-1/output-volt gt 130
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/idg-1/gcu-1-frequency-trip">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/sources/idg-1/gcu-1-frequency-trip eq 1
|
|
/controls/electrical/switches/gen-1 eq 1
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/relay/gen-1-glc/contact-pos eq 1
|
|
<test logic="OR">
|
|
/systems/electrical/sources/idg-1/output-hertz lt 363
|
|
/systems/electrical/sources/idg-1/output-hertz gt 433
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/idg-1/gcu-1-fault">
|
|
<default value="0"/>
|
|
<test logic="OR" value="0">
|
|
/systems/acconfig/autoconfig-running eq 1
|
|
/sim/time/elapsed-sec lt 10
|
|
</test>
|
|
<test logic="OR" value="1">
|
|
/systems/electrical/sources/idg-1/gcu-1-voltage-trip eq 1
|
|
/systems/electrical/sources/idg-1/gcu-1-frequency-trip eq 1
|
|
/systems/electrical/sources/idg-1/drive-rpm lt 4730
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/gen-1-glc/contact-pos">
|
|
<default value="0"/>
|
|
<test logic="OR" value="0">
|
|
/sim/time/elapsed-sec lt 10
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/controls/electrical/switches/gen-1 eq 1
|
|
/systems/electrical/sources/idg-1/output-hertz ge 363
|
|
/systems/electrical/sources/idg-1/output-hertz le 433
|
|
/systems/electrical/sources/idg-1/output-volt ge 110
|
|
/systems/electrical/sources/idg-1/output-volt le 130
|
|
/systems/electrical/sources/idg-1/gcu-1-fault ne 1 <!-- software trip -->
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/gen-1-glc/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/sources/idg-1/output-volt">
|
|
/systems/electrical/relay/gen-1-glc/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/idg-2/gcu-2-powered">
|
|
<default value="0"/>
|
|
<test logic="OR" value="1">
|
|
/systems/electrical/bus/dc-bat ge 25
|
|
/systems/electrical/sources/idg-2/pmg-volt ge 110
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/idg-2/gcu-2-voltage-trip">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/sources/idg-2/gcu-2-voltage-trip eq 1
|
|
/controls/electrical/switches/gen-2 eq 1
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/relay/gen-2-glc/contact-pos eq 1
|
|
<test logic="OR">
|
|
/systems/electrical/sources/idg-2/output-volt lt 110
|
|
/systems/electrical/sources/idg-2/output-volt gt 130
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/idg-2/gcu-2-frequency-trip">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/sources/idg-2/gcu-2-frequency-trip eq 1
|
|
/controls/electrical/switches/gen-2 eq 1
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/relay/gen-2-glc/contact-pos eq 1
|
|
<test logic="OR">
|
|
/systems/electrical/sources/idg-2/output-hertz lt 363
|
|
/systems/electrical/sources/idg-2/output-hertz gt 433
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/sources/idg-2/gcu-2-fault">
|
|
<default value="0"/>
|
|
<test logic="OR" value="0">
|
|
/systems/acconfig/autoconfig-running eq 1
|
|
/sim/time/elapsed-sec lt 10
|
|
</test>
|
|
<test logic="OR" value="1">
|
|
/systems/electrical/sources/idg-2/gcu-2-voltage-trip eq 1
|
|
/systems/electrical/sources/idg-2/gcu-2-frequency-trip eq 1
|
|
/systems/electrical/sources/idg-2/drive-rpm lt 4730
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/gen-2-glc/contact-pos">
|
|
<default value="0"/>
|
|
<test logic="OR" value="0">
|
|
/sim/time/elapsed-sec lt 10
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/controls/electrical/switches/gen-2 eq 1
|
|
/systems/electrical/sources/idg-2/output-hertz ge 363
|
|
/systems/electrical/sources/idg-2/output-hertz le 433
|
|
/systems/electrical/sources/idg-2/output-volt ge 110
|
|
/systems/electrical/sources/idg-2/output-volt le 130
|
|
/systems/electrical/sources/idg-2/gcu-2-fault ne 1 <!-- software trip -->
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/gen-2-glc/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/sources/idg-2/output-volt">
|
|
/systems/electrical/relay/gen-2-glc/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ext-epc/contact-pos">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/sources/ext/output-volt ge 110
|
|
/controls/electrical/switches/ext-pwr eq 1
|
|
/controls/electrical/ground-cart eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ext-epc/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/sources/ext/output-volt">
|
|
/systems/electrical/relay/ext-epc/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/apu-glc/contact-pos">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/apu/master eq 1
|
|
/controls/electrical/switches/apu eq 1
|
|
/systems/electrical/sources/apu/output-volt ge 110
|
|
/systems/electrical/sources/apu/output-volt lt 130
|
|
/systems/electrical/sources/apu/output-hertz ge 390
|
|
/systems/electrical/sources/apu/output-hertz le 410
|
|
/systems/electrical/relay/ext-epc/contact-pos eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/apu-glc/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/sources/apu/output-volt">
|
|
/systems/electrical/relay/apu-glc/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/emer-glc/contact-pos">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/sources/emer-gen/output-volt ge 110
|
|
/systems/failures/electrical/emer-gen ne 1
|
|
/systems/electrical/relay/ac-ess-feed-1/output lt 110
|
|
/systems/electrical/relay/ac-ess-feed-2/output lt 110
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/emer-glc/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/sources/emer-gen/output-volt">
|
|
/systems/electrical/relay/emer-glc/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
|
|
<!-- AC Bus Tie AC Bus Relays -->
|
|
<!-- These outputs are from the AC Bus Tie to the AC Bus -->
|
|
<switch name="/systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos">
|
|
<default value="0"/>
|
|
<test value="0">
|
|
/controls/electrical/switches/bus-tie eq 0
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/relay/gen-1-glc/contact-pos eq 1
|
|
/systems/electrical/relay/gen-2-glc/contact-pos eq 0
|
|
/systems/electrical/relay/apu-glc/contact-pos eq 0
|
|
/systems/electrical/relay/ext-epc/contact-pos eq 0
|
|
/controls/electrical/switches/bus-tie eq 1
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/relay/gen-1-glc/contact-pos eq 0
|
|
/systems/electrical/bus/ac-bus-tie ge 110
|
|
/controls/electrical/switches/bus-tie eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ac-bus-ac-bus-tie-1/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/ac-bus-tie">
|
|
/systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos">
|
|
<default value="0"/>
|
|
<test value="0">
|
|
/controls/electrical/switches/bus-tie eq 0
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/relay/gen-2-glc/contact-pos eq 1
|
|
/systems/electrical/relay/gen-1-glc/contact-pos eq 0
|
|
/systems/electrical/relay/apu-glc/contact-pos eq 0
|
|
/systems/electrical/relay/ext-epc/contact-pos eq 0
|
|
/controls/electrical/switches/bus-tie eq 1
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/relay/gen-2-glc/contact-pos eq 0
|
|
/systems/electrical/bus/ac-bus-tie ge 110
|
|
/controls/electrical/switches/bus-tie eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ac-bus-ac-bus-tie-2/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/ac-bus-tie">
|
|
/systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- AC ESS Relays -->
|
|
<switch name="/systems/electrical/relay/ac-ess-feed-1/contact-pos"> <!-- TODO: via 1XC CB on 123VU -->
|
|
<default value="0"/>
|
|
<test logic="AND" value="1"> <!-- old AC ESS FEED supply mode -->
|
|
/controls/electrical/switches/ac-ess-feed eq 0
|
|
/controls/electrical/switches/emer-gen-test eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ac-ess-feed-1/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/ac-1">
|
|
/systems/electrical/relay/ac-ess-feed-1/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ac-ess-feed-2/contact-pos"> <!-- TODO: via 2XC CB on 123VU -->
|
|
<default value="0"/>
|
|
<test logic="AND" value="1"> <!-- old AC ESS FEED supply mode -->
|
|
/controls/electrical/switches/ac-ess-feed eq 1
|
|
/controls/electrical/switches/emer-gen-test eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ac-ess-feed-2/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/ac-2">
|
|
/systems/electrical/relay/ac-ess-feed-2/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ac-ess-feed-emer-gen/contact-pos">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/bus/ac-1 eq 0
|
|
/systems/electrical/bus/ac-2 eq 0
|
|
/systems/electrical/relay/emer-glc/output ge 110
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/bus/ac-1 ne 0
|
|
/systems/electrical/bus/ac-2 ne 0
|
|
/controls/electrical/switches/emer-gen-test eq 1
|
|
/systems/electrical/relay/emer-glc/output ge 110
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ac-ess-feed-emer-gen/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/relay/emer-glc/output">
|
|
/systems/electrical/relay/ac-ess-feed-emer-gen/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ac-ess-feed-inverter/contact-pos">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/instrumentation/airspeed-indicator/indicated-speed-kt ge 50
|
|
/systems/electrical/bus/ac-1 eq 0
|
|
/systems/electrical/bus/ac-2 eq 0
|
|
/controls/electrical/switches/emer-gen-test eq 0
|
|
/systems/electrical/relay/emer-glc/output lt 110
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ac-ess-feed-inverter/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/sources/si-1/output-volt">
|
|
/systems/electrical/relay/ac-ess-feed-inverter/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- AC ESS Shedding -->
|
|
<switch name="/systems/electrical/relay/ac-ess-shed-switch/contact-pos">
|
|
<default value="1"/>
|
|
<test logic="OR" value="0"> <!-- TODO: confirm these conditions are for galley, NOT ESS -->
|
|
/systems/electrical/sources/si-1/inverter-active eq 1
|
|
/controls/electrical/switches/emer-gen-test eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ac-ess-shed-switch/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/ac-ess">
|
|
/systems/electrical/relay/ac-ess-shed-switch/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- Galleys -->
|
|
<fcs_function name="/systems/electrical/some-electric-thingie/galley-shed-sum">
|
|
<function>
|
|
<sum>
|
|
<property>/systems/electrical/relay/apu-glc/contact-pos</property>
|
|
<property>/systems/electrical/relay/ext-epc/contact-pos</property>
|
|
<property>/systems/electrical/relay/gen-1-glc/contact-pos</property>
|
|
<property>/systems/electrical/relay/gen-2-glc/contact-pos</property>
|
|
</sum>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<switch name="/systems/electrical/relay/galley-bus-1-shed-switch/contact-pos">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/electrical/switches/galley eq 1
|
|
<test logic="OR">
|
|
<test logic="AND">
|
|
/gear/gear[1]/wow eq 0
|
|
/systems/electrical/some-electric-thingie/galley-shed-sum gt 1
|
|
</test>
|
|
<test logic="AND">
|
|
/gear/gear[1]/wow eq 1
|
|
<test logic="OR">
|
|
/systems/electrical/relay/apu-glc/output ge 110
|
|
/systems/electrical/relay/ext-epc/output ge 110
|
|
<test logic="AND">
|
|
/systems/electrical/relay/gen-1-glc/output ge 110
|
|
/systems/electrical/relay/gen-2-glc/output ge 110
|
|
</test>
|
|
</test>
|
|
</test>
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/galley-bus-1-shed-switch/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/ac-1">
|
|
/systems/electrical/relay/galley-bus-1-shed-switch/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/galley-bus-2-shed-switch/contact-pos">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/electrical/switches/galley eq 1
|
|
<test logic="OR">
|
|
<test logic="AND">
|
|
/gear/gear[1]/wow eq 0
|
|
/systems/electrical/some-electric-thingie/galley-shed-sum gt 1
|
|
</test>
|
|
<test logic="AND">
|
|
/gear/gear[1]/wow eq 1
|
|
<test logic="OR">
|
|
/systems/electrical/relay/apu-glc/output ge 110
|
|
/systems/electrical/relay/ext-epc/output ge 110
|
|
<test logic="AND">
|
|
/systems/electrical/relay/gen-1-glc/output ge 110
|
|
/systems/electrical/relay/gen-2-glc/output ge 110
|
|
</test>
|
|
</test>
|
|
</test>
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/galley-bus-2-shed-switch/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/ac-2">
|
|
/systems/electrical/relay/galley-bus-2-shed-switch/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/some-electric-thingie/galley-shed">
|
|
<default value="0"/>
|
|
<test logic="OR" value="1">
|
|
/systems/electrical/relay/galley-bus-1-shed-switch/contact-pos eq 0
|
|
/systems/electrical/relay/galley-bus-2-shed-switch/contact-pos eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- AC Bus 1 -->
|
|
<switch name="/systems/electrical/bus/ac-1-src">
|
|
<description>Tell which source is being used for priority purpose</description>
|
|
<default value="0"/> <!-- OFF -->
|
|
<test value="1"> <!-- IDG1 -->
|
|
/systems/electrical/relay/gen-1-glc/contact-pos eq 1
|
|
</test>
|
|
<test value="2"> <!-- Bus Tie -->
|
|
/systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<fcs_function name="/systems/electrical/bus/ac-1">
|
|
<function>
|
|
<ifthen>
|
|
<eq>
|
|
<property>/systems/failures/electrical/ac-1-bus</property>
|
|
<value>1</value>
|
|
</eq>
|
|
<value>0</value>
|
|
<max>
|
|
<property>/systems/electrical/relay/gen-1-glc/output</property>
|
|
<property>/systems/electrical/relay/ac-bus-ac-bus-tie-1/output</property>
|
|
</max>
|
|
</ifthen>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<!-- AC Bus 2 -->
|
|
<switch name="/systems/electrical/bus/ac-2-src">
|
|
<description>Tell which source is being used for priority purpose</description>
|
|
<default value="0"/> <!-- OFF -->
|
|
<test value="1"> <!-- IDG2 -->
|
|
/systems/electrical/relay/gen-2-glc/contact-pos eq 1
|
|
</test>
|
|
<test value="2"> <!-- Bus Tie -->
|
|
/systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<fcs_function name="/systems/electrical/bus/ac-2">
|
|
<function>
|
|
<ifthen>
|
|
<eq>
|
|
<property>/systems/failures/electrical/ac-2-bus</property>
|
|
<value>1</value>
|
|
</eq>
|
|
<value>0</value>
|
|
<max>
|
|
<property>/systems/electrical/relay/gen-2-glc/output</property>
|
|
<property>/systems/electrical/relay/ac-bus-ac-bus-tie-2/output</property>
|
|
</max>
|
|
</ifthen>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<pure_gain name="/systems/electrical/bus/ac-1-26v"> <!-- TODO: via 5XN1 CB on 123VU, supplies ADIRS -->
|
|
<input>/systems/electrical/bus/ac-1</input>
|
|
<gain>0.2260869565</gain>
|
|
</pure_gain>
|
|
|
|
<pure_gain name="/systems/electrical/bus/ac-2-26v"> <!-- TODO: via 5XN2 CB on 123VU, supplies ADIRS -->
|
|
<input>/systems/electrical/bus/ac-2</input>
|
|
<gain>0.2260869565</gain>
|
|
</pure_gain>
|
|
|
|
<pure_gain name="/systems/electrical/bus/ac-ess-26v"> <!-- TODO: via 4XH CB on 106VU -->
|
|
<input>/systems/electrical/bus/ac-ess</input>
|
|
<gain>0.2260869565</gain>
|
|
</pure_gain>
|
|
|
|
<pure_gain name="/systems/electrical/bus/ac-si-bus"> <!-- feeds landing gear indication, apu fuel pump, some annunciators, a injectors if RAT is out, only if stat inv is on -->
|
|
<input>/systems/electrical/sources/si-1/output-volt</input> <!-- TODO: via 12XB CB on 105VU -->
|
|
<gain>1</gain>
|
|
</pure_gain>
|
|
|
|
<fcs_function name="/systems/electrical/bus/ac-ess">
|
|
<function>
|
|
<ifthen>
|
|
<eq>
|
|
<property>/systems/failures/electrical/ac-ess-bus</property>
|
|
<value>1</value>
|
|
</eq>
|
|
<value>0</value>
|
|
<max>
|
|
<property>/systems/electrical/relay/ac-ess-feed-1/output</property>
|
|
<property>/systems/electrical/relay/ac-ess-feed-2/output</property>
|
|
<property>/systems/electrical/relay/ac-ess-feed-emer-gen/output</property>
|
|
<property>/systems/electrical/relay/ac-ess-feed-inverter/output</property>
|
|
</max>
|
|
</ifthen>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<pure_gain name="/systems/electrical/bus/ac-ess-shed">
|
|
<input>/systems/electrical/relay/ac-ess-shed-switch/output</input>
|
|
<gain>/systems/electrical/relay/ac-ess-shed-switch/contact-pos</gain>
|
|
</pure_gain>
|
|
|
|
<!-- AC Bus Tie AC Bus Relays (continued) -->
|
|
<!-- These outputs are from the AC Bus to the AC Bus Tie -->
|
|
<switch name="/systems/electrical/relay/ac-bus-ac-bus-tie-1/output-tie">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/ac-1">
|
|
/systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/ac-bus-ac-bus-tie-2/output-tie">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/ac-2">
|
|
/systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- AC Bus Tie -->
|
|
<switch name="/systems/electrical/bus/ac-bus-tie">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/relay/ext-epc/output">
|
|
/systems/electrical/relay/ext-epc/contact-pos eq 1
|
|
</test>
|
|
<test value="/systems/electrical/relay/apu-glc/output">
|
|
/systems/electrical/relay/apu-glc/contact-pos eq 1
|
|
</test>
|
|
<test logic="AND" value="/systems/electrical/relay/ac-bus-ac-bus-tie-1/output-tie">
|
|
/systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1
|
|
/systems/electrical/bus/ac-1-src ne 2
|
|
</test>
|
|
<test logic="AND" value="/systems/electrical/relay/ac-bus-ac-bus-tie-2/output-tie">
|
|
/systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1
|
|
/systems/electrical/bus/ac-2-src ne 2
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- Transformer Rectifiers -->
|
|
<pure_gain name="/systems/electrical/sources/tr-1/output-volt">
|
|
<input>/systems/electrical/bus/ac-1</input> <!-- TODO: via 2PU1 CB -->
|
|
<gain>0.24347826086956523</gain> <!-- AC to DC converter -->
|
|
</pure_gain>
|
|
|
|
<fcs_function name="/systems/electrical/sources/tr-1/output-amp"> <!-- TODO: make it depend on current draw -->
|
|
<function>
|
|
<table>
|
|
<independentVar lookup="row">/systems/electrical/sources/tr-1/output-volt</independentVar>
|
|
<tableData>
|
|
0 0
|
|
27.5 200
|
|
</tableData>
|
|
</table>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<pure_gain name="/systems/electrical/sources/tr-2/output-volt">
|
|
<input>/systems/electrical/bus/ac-2</input> <!-- TODO: via 2PU2 CB -->
|
|
<gain>0.24347826086956523</gain> <!-- AC to DC converter -->
|
|
</pure_gain>
|
|
|
|
<fcs_function name="/systems/electrical/sources/tr-2/output-amp"> <!-- TODO: make it depend on current draw -->
|
|
<function>
|
|
<table>
|
|
<independentVar lookup="row">/systems/electrical/sources/tr-2/output-volt</independentVar>
|
|
<tableData>
|
|
0 0
|
|
27.5 200
|
|
</tableData>
|
|
</table>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<switch name="/systems/electrical/sources/ess-tr/working">
|
|
<default value="0"/>
|
|
<test value="0.24347826086956523">
|
|
/systems/failures/electrical/ess-tr eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<pure_gain name="/systems/electrical/sources/ess-tr/output-volt">
|
|
<input>/systems/electrical/bus/ac-ess</input> <!-- TODO: via 2PU1 CB -->
|
|
<gain>/systems/electrical/sources/ess-tr/working</gain> <!-- AC to DC converter -->
|
|
</pure_gain>
|
|
|
|
<fcs_function name="/systems/electrical/sources/ess-tr/output-amp"> <!-- TODO: make it depend on current draw -->
|
|
<function>
|
|
<table>
|
|
<independentVar lookup="row">/systems/electrical/sources/ess-tr/output-volt</independentVar>
|
|
<tableData>
|
|
0 0
|
|
27.5 200
|
|
</tableData>
|
|
</table>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<!-- Transformer Rectifier Contactors (Relays) -->
|
|
<switch name="/systems/electrical/relay/tr-contactor-1/contact-pos">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/sources/tr-1/output-volt ne 0
|
|
/systems/electrical/sources/tr-1/output-amp ne 0
|
|
/systems/failures/electrical/tr-1 eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/tr-contactor-1/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/sources/tr-1/output-volt">
|
|
/systems/electrical/relay/tr-contactor-1/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/tr-contactor-1/output-amp">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/sources/tr-1/output-amp">
|
|
/systems/electrical/relay/tr-contactor-1/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/tr-contactor-2/contact-pos">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/sources/tr-2/output-volt ne 0
|
|
/systems/electrical/sources/tr-2/output-amp ne 0
|
|
/systems/failures/electrical/tr-2 eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/tr-contactor-2/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/sources/tr-2/output-volt">
|
|
/systems/electrical/relay/tr-contactor-2/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/tr-contactor-2/output-amp">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/sources/tr-2/output-amp">
|
|
/systems/electrical/relay/tr-contactor-2/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- DC Bus Tie Relays -->
|
|
<switch name="/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/bus/ac-1 ge 110
|
|
/systems/electrical/bus/dc-1 ge 25
|
|
/systems/electrical/relay/tr-contactor-1/contact-pos eq 1
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/bus/dc-bat ge 25
|
|
/systems/electrical/bus/dc-bat-src ne 3
|
|
<test logic="OR">
|
|
/systems/electrical/relay/tr-contactor-1/contact-pos eq 0
|
|
/systems/electrical/relay/tr-contactor-2/contact-pos eq 0
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/dc-bus-tie-dc-1/output">
|
|
<default value="0"/>
|
|
<test logic="AND" value="/systems/electrical/bus/dc-bat">
|
|
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/relay/dc-ess-feed-bat/contact-pos eq 0
|
|
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 0
|
|
/systems/electrical/relay/tr-contactor-2/contact-pos eq 1
|
|
/systems/electrical/bus/dc-2 ge 25
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/bus/dc-bat ge 25
|
|
/systems/electrical/bus/dc-bat-src ne 3
|
|
<test logic="OR">
|
|
/systems/electrical/relay/tr-contactor-1/contact-pos eq 0
|
|
/systems/electrical/relay/tr-contactor-2/contact-pos eq 0
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/dc-bus-tie-dc-2/output">
|
|
<default value="0"/>
|
|
<test logic="AND" value="/systems/electrical/bus/dc-bat">
|
|
/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- DC ESS Relays -->
|
|
<switch name="/systems/electrical/relay/dc-ess-feed-tr/contact-pos"> <!-- TODO: supply via 4PE CB on 106VU, contactor via 5PE on 106VU -->
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
<test logic="OR">
|
|
/systems/electrical/relay/tr-contactor-1/output lt 25
|
|
/systems/electrical/relay/tr-contactor-2/output lt 25
|
|
/systems/electrical/relay/emer-glc/output ge 110
|
|
</test>
|
|
/systems/electrical/sources/ess-tr/output-volt ge 25
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/dc-ess-feed-tr/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/sources/ess-tr/output-volt">
|
|
/systems/electrical/relay/dc-ess-feed-tr/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/dc-ess-feed-tr/output-amp">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/sources/ess-tr/output-amp">
|
|
/systems/electrical/relay/dc-ess-feed-tr/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/dc-ess-feed-bat/contact-pos"> <!-- TODO: via 20PC1 80A fuse on 120VU -->
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/relay/dc-ess-feed-tr/contact-pos eq 0
|
|
<test logic="OR">
|
|
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 0
|
|
/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 0
|
|
</test>
|
|
/controls/electrical/switches/emer-gen-test eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/dc-ess-feed-bat/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/dc-bat">
|
|
/systems/electrical/relay/dc-ess-feed-bat/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- DC Ess Shedding -->
|
|
<switch name="/systems/electrical/relay/dc-ess-shed-switch/contact-pos">
|
|
<default value="1"/>
|
|
<test logic="OR" value="0"> <!-- TODO: confirm these conditions are for galley, NOT ESS -->
|
|
/systems/electrical/sources/si-1/inverter-active eq 1
|
|
/controls/electrical/switches/emer-gen-test eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/dc-ess-shed-switch/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/dc-ess">
|
|
/systems/electrical/relay/dc-ess-shed-switch/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- DC Service Bus -->
|
|
<switch name="/systems/electrical/relay/dc-svc-bus-contactor-tr/contact-pos"> <!-- TODO: via 1PX CB on 124VU -->
|
|
<default value="0"/>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/dc-svc-bus-contactor-tr/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/relay/tr-contactor-2/output">
|
|
/systems/electrical/relay/dc-svc-bus-contactor-tr/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/dc-svc-bus-contactor-bus-2/contact-pos"> <!-- TODO: via 7PN CB on 124VU -->
|
|
<default value="1"/>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/dc-svc-bus-contactor-bus-2/output">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/dc-2">
|
|
/systems/electrical/relay/dc-svc-bus-contactor-bus-2/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- DC Bus 1 -->
|
|
<switch name="/systems/electrical/bus/dc-1-src">
|
|
<description>Tell which source is being used for priority purpose</description>
|
|
<default value="0"/> <!-- OFF -->
|
|
<test value="1"> <!-- TR1 -->
|
|
/systems/electrical/relay/tr-contactor-1/output ge 25
|
|
</test>
|
|
<test value="2"> <!-- DC BAT -->
|
|
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<fcs_function name="/systems/electrical/bus/dc-1">
|
|
<function>
|
|
<ifthen>
|
|
<eq>
|
|
<property>/systems/failures/electrical/dc-1-bus</property>
|
|
<value>1</value>
|
|
</eq>
|
|
<value>0</value>
|
|
<max>
|
|
<property>/systems/electrical/relay/tr-contactor-1/output</property>
|
|
<property>/systems/electrical/relay/dc-bus-tie-dc-1/output</property>
|
|
</max>
|
|
</ifthen>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<!-- DC Bus 2 -->
|
|
<switch name="/systems/electrical/bus/dc-2-src">
|
|
<description>Tell which source is being used for priority purpose</description>
|
|
<default value="0"/> <!-- OFF -->
|
|
<test value="1"> <!-- TR1 -->
|
|
/systems/electrical/relay/tr-contactor-2/output ge 25
|
|
</test>
|
|
<test value="2"> <!-- DC BAT -->
|
|
/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<fcs_function name="/systems/electrical/bus/dc-2">
|
|
<function>
|
|
<ifthen>
|
|
<eq>
|
|
<property>/systems/failures/electrical/dc-2-bus</property>
|
|
<value>1</value>
|
|
</eq>
|
|
<value>0</value>
|
|
<max>
|
|
<property>/systems/electrical/relay/tr-contactor-2/output</property>
|
|
<property>/systems/electrical/relay/dc-bus-tie-dc-2/output</property>
|
|
</max>
|
|
</ifthen>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<fcs_function name="/systems/electrical/bus/dc-service-bus">
|
|
<function>
|
|
<max>
|
|
<property>/systems/electrical/relay/dc-svc-bus-contactor-tr/output</property>
|
|
<property>/systems/electrical/relay/dc-svc-bus-contactor-bus-2/output</property>
|
|
</max>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<!-- DC Bus Tie DC Bus Relays (continued) -->
|
|
<!-- These outputs are from the DC Bus to the DC Bus Tie -->
|
|
<switch name="/systems/electrical/relay/dc-bus-tie-dc-1/output-tie">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/dc-1">
|
|
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/relay/dc-bus-tie-dc-2/output-tie">
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/dc-2">
|
|
/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- DC Bat Bus -->
|
|
<switch name="/systems/electrical/bus/dc-bat-src">
|
|
<description>Tell which source is being used for priority purpose</description>
|
|
<default value="0"/> <!-- OFF -->
|
|
<test value="1"> <!-- DC1 -->
|
|
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1
|
|
/systems/electrical/bus/dc-1-src ne 2
|
|
</test>
|
|
<test value="2"> <!-- DC2 -->
|
|
/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1
|
|
/systems/electrical/bus/dc-2-src ne 2
|
|
</test>
|
|
<test logic="OR" value="3"> <!-- BAT -->
|
|
<test logic="AND">
|
|
/instrumentation/airspeed-indicator/indicated-speed-kt lt 100
|
|
<test logic="OR">
|
|
/controls/electrical/switches/bat-1 eq 1
|
|
/controls/electrical/switches/bat-2 eq 1
|
|
</test>
|
|
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
|
|
</test>
|
|
<test logic="AND">
|
|
<test logic="OR">
|
|
/controls/electrical/switches/bat-1 eq 1
|
|
/controls/electrical/switches/bat-2 eq 1
|
|
</test>
|
|
/systems/apu/dc-bat-three-minutes eq 1
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/bus/dc-bat">
|
|
<default value="0"/>
|
|
<test value="0">
|
|
/systems/failures/electrical/dc-bat-bus eq 1
|
|
</test>
|
|
<test logic="AND" value="/systems/electrical/relay/dc-bus-tie-dc-1/output-tie">
|
|
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1
|
|
/systems/electrical/bus/dc-1-src ne 2
|
|
</test>
|
|
<test logic="AND" value="/systems/electrical/relay/dc-bus-tie-dc-2/output-tie">
|
|
/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1
|
|
/systems/electrical/bus/dc-2-src ne 2
|
|
</test>
|
|
<test logic="OR" value="/systems/electrical/sources/bat-1/volt">
|
|
<test logic="AND">
|
|
/instrumentation/airspeed-indicator/indicated-speed-kt lt 100
|
|
/controls/electrical/switches/bat-1 eq 1
|
|
/systems/electrical/bus/dc-bat-src eq 3
|
|
/systems/electrical/sources/bat-1/volt ge 25
|
|
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
|
|
</test>
|
|
<test logic="AND">
|
|
/systems/apu/dc-bat-three-minutes eq 1
|
|
/controls/electrical/switches/bat-1 eq 1
|
|
/systems/electrical/bus/dc-bat-src eq 3
|
|
/systems/electrical/sources/bat-1/volt ge 25
|
|
</test>
|
|
</test>
|
|
<test logic="OR" value="/systems/electrical/sources/bat-2/volt">
|
|
<test logic="AND">
|
|
/instrumentation/airspeed-indicator/indicated-speed-kt lt 100
|
|
/controls/electrical/switches/bat-2 eq 1
|
|
/systems/electrical/bus/dc-bat-src eq 3
|
|
/systems/electrical/sources/bat-2/volt ge 25
|
|
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
|
|
</test>
|
|
<test logic="AND">
|
|
/systems/apu/dc-bat-three-minutes eq 1
|
|
/controls/electrical/switches/bat-2 eq 1
|
|
/systems/electrical/bus/dc-bat-src eq 3
|
|
/systems/electrical/sources/bat-2/volt ge 25
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- DC ESS Bus -->
|
|
<fcs_function name="/systems/electrical/bus/dc-ess">
|
|
<function>
|
|
<ifthen>
|
|
<eq>
|
|
<property>/systems/failures/electrical/dc-ess-bus</property>
|
|
<value>1</value>
|
|
</eq>
|
|
<value>0</value>
|
|
<max>
|
|
<property>/systems/electrical/relay/dc-ess-feed-bat/output</property>
|
|
<property>/systems/electrical/relay/dc-ess-feed-tr/output</property>
|
|
</max>
|
|
</ifthen>
|
|
</function>
|
|
</fcs_function>
|
|
|
|
<pure_gain name="/systems/electrical/bus/dc-ess-shed">
|
|
<input>/systems/electrical/bus/dc-ess</input>
|
|
<gain>1</gain>
|
|
</pure_gain>
|
|
|
|
<!-- Hot Buses -->
|
|
<pure_gain name="/systems/electrical/bus/dc-hot-1">
|
|
<input>/systems/electrical/sources/bat-1/volt</input> <!-- todo CB 12PB1 / 5PB1 -->
|
|
<gain>1.0</gain>
|
|
</pure_gain>
|
|
|
|
<pure_gain name="/systems/electrical/bus/dc-hot-2">
|
|
<input>/systems/electrical/sources/bat-2/volt</input> <!-- todo CB 12PB2 / 5PB2 -->
|
|
<gain>1.0</gain>
|
|
</pure_gain>
|
|
|
|
<switch name="/systems/electrical/some-electric-thingie/emer-elec-config">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/bus/ac-1 lt 110
|
|
/systems/electrical/bus/ac-2 lt 110
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/relay/ext-epc/contact-pos eq 0
|
|
<test logic="OR">
|
|
/controls/electrical/switches/gen-1 eq 0
|
|
/systems/failures/electrical/gen-1 eq 1
|
|
</test>
|
|
<test logic="OR">
|
|
/controls/electrical/switches/gen-2 eq 0
|
|
/systems/failures/electrical/gen-2 eq 1
|
|
</test>
|
|
<test logic="OR">
|
|
/controls/electrical/switches/apu eq 0
|
|
/systems/failures/electrical/apu eq 1
|
|
/engines/engine[2]/n1 lt 94.9
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/some-electric-thingie/emer-elec-config-generator-1-bustie">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
|
|
/systems/electrical/some-electric-thingie/generator-1-pb eq 1
|
|
/controls/electrical/switches/bus-tie eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/some-electric-thingie/emer-elec-config-generator-2-bustie">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
|
|
/systems/electrical/some-electric-thingie/generator-2-pb eq 1
|
|
/controls/electrical/switches/bus-tie eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/some-electric-thingie/emer-elec-config-generator-1">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
|
|
/systems/electrical/some-electric-thingie/generator-1-pb eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/some-electric-thingie/emer-elec-config-generator-2">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
|
|
/systems/electrical/some-electric-thingie/generator-2-pb eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<actuator name="/systems/electrical/some-electric-thingie/static-inverter-timer">
|
|
<description>Timer for the ECAM system</description>
|
|
<input>/systems/electrical/relay/ac-ess-feed-inverter/contact-pos</input>
|
|
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
|
|
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
|
|
</actuator>
|
|
|
|
<!-- Output to Generics to keep FG things working, temporary, until we know what gets power by what bus -->
|
|
<switch name="/systems/electrical/generic-pwr">
|
|
<description>This makes the FG stuff work because we killed the generic electrical</description>
|
|
<default value="0"/>
|
|
<test value="/systems/electrical/bus/dc-1">
|
|
/systems/electrical/bus/dc-1 ge 25
|
|
</test>
|
|
<test value="/systems/electrical/bus/dc-2">
|
|
/systems/electrical/bus/dc-2 ge 25
|
|
</test>
|
|
<!--<output>/systems/electrical/outputs/adf</output>
|
|
<output>/systems/electrical/outputs/dme</output>-->
|
|
<output>/systems/electrical/outputs/efis</output>
|
|
<output>/systems/electrical/outputs/fcp-power</output>
|
|
<output>/systems/electrical/outputs/fuel-pump[0]</output>
|
|
<output>/systems/electrical/outputs/fuel-pump[1]</output>
|
|
<output>/systems/electrical/outputs/fuel-pump[2]</output>
|
|
<output>/systems/electrical/outputs/gps</output>
|
|
<output>/systems/electrical/outputs/mk-viii</output>
|
|
<!--<output>/systems/electrical/outputs/nav[0]</output>
|
|
<output>/systems/electrical/outputs/nav[1]</output>
|
|
<output>/systems/electrical/outputs/nav[2]</output>
|
|
<output>/systems/electrical/outputs/nav[3]</output>-->
|
|
<output>/systems/electrical/outputs/tacan</output>
|
|
<output>/systems/electrical/outputs/turn-coordinator</output>
|
|
</switch>
|
|
</channel>
|
|
|
|
<!-- Notes -->
|
|
<!-- Priority: eng, ext, apu but EXT ON lt stays on even when not feeding a/c -->
|
|
<!-- TR 2 fail leads to loss of gnd FLT bus -->
|
|
|
|
<channel name="Overhead Lights" execrate="8">
|
|
|
|
<switch name="/systems/electrical/light/ac-ess-feed-fault">
|
|
<default value="0"/>
|
|
<test value="1">
|
|
/systems/electrical/bus/ac-ess lt 110
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/light/apu-fault">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/electrical/switches/apu eq 1
|
|
/systems/electrical/relay/apu-glc/contact-pos eq 0
|
|
/systems/electrical/relay/ext-epc/contact-pos eq 0
|
|
/systems/electrical/relay/gen-1-glc/contact-pos eq 0
|
|
/systems/electrical/relay/gen-2-glc/contact-pos eq 0
|
|
/systems/electrical/sources/apu/drive-rpm gt 2000
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/light/bat-1-fault">
|
|
<default value="0"/>
|
|
<test value="1"> <!-- TODO: depends charging current -->
|
|
/systems/failures/electrical/bat-1 eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/light/bat-2-fault">
|
|
<default value="0"/>
|
|
<test value="1"> <!-- TODO: depends charging current -->
|
|
/systems/failures/electrical/bat-2 eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<!-- TODO: galley fault when load > 100 -->
|
|
<switch name="/systems/electrical/light/galley-fault">
|
|
<default value="0"/>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/light/gen-1-fault">
|
|
<default value="0"/>
|
|
<test value="1">
|
|
/controls/electrical/switches/gen-1 eq 1
|
|
<test logic="OR">
|
|
/systems/electrical/sources/idg-1/gcu-1-fault eq 1
|
|
/systems/electrical/relay/gen-1-glc/contact-pos eq 0
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/light/gen-2-fault">
|
|
<default value="0"/>
|
|
<test value="1">
|
|
/controls/electrical/switches/gen-2 eq 1
|
|
<test logic="OR">
|
|
/systems/electrical/sources/idg-2/gcu-2-fault eq 1
|
|
/systems/electrical/relay/gen-2-glc/contact-pos eq 0
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/light/idg-1-fault">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/failures/electrical/idg-1 eq 1
|
|
/systems/electrical/sources/idg-1/drive-rpm gt 2000
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/controls/electrical/switches/idg-1-disc-momentary eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/light/idg-2-fault">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/failures/electrical/idg-2 eq 1
|
|
/systems/electrical/sources/idg-2/drive-rpm gt 2000
|
|
</test>
|
|
<test logic="AND" value="1">
|
|
/controls/electrical/switches/idg-2-disc-momentary eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/electrical/light/rat-emer-gen-fault">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/electrical/relay/dc-ess-feed-tr/output eq 0
|
|
/systems/electrical/bus/ac-1 eq 0
|
|
/systems/electrical/bus/ac-2 eq 0
|
|
position/wow eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
</channel>
|
|
|
|
</system>
|