<!-- Airbus A320 Fuel -->
|
|
|
|
<!-- Copyright (c) 2019 Jonathan Redpath -->
|
|
|
|
<system name="A320: Fuel:">
|
|
|
|
<channel name="Fuel Pumps and Valves">
|
|
<!-- Pumps -->
|
|
<switch name="/systems/fuel/pumps/wing-pump-left-1-operate">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/switches/fuel/pump-left-1 eq 1
|
|
<test logic="OR">
|
|
<test logic="AND">
|
|
/systems/electrical/sources/idg-1/pmg-volt ge 110
|
|
/controls/electrical/switches/gen-1-line-contactor eq 1
|
|
</test>
|
|
/systems/electrical/bus/ac-1 ge 110
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/fuel/pumps/wing-pump-left-2-operate">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/switches/fuel/pump-left-2 eq 1
|
|
/systems/electrical/bus/ac-2 ge 110
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/fuel/pumps/wing-pump-right-1-operate">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/switches/fuel/pump-right-1 eq 1
|
|
<test logic="OR">
|
|
<test logic="AND">
|
|
/systems/electrical/sources/idg-1/pmg-volt ge 110
|
|
/controls/electrical/switches/gen-1-line-contactor eq 1
|
|
</test>
|
|
/systems/electrical/bus/ac-1 ge 110
|
|
</test>
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/fuel/pumps/wing-pump-right-2-operate">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/switches/fuel/pump-right-2 eq 1
|
|
/systems/electrical/bus/ac-2 ge 110
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/fuel/pumps/center-pump-1-operate">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/switches/fuel/pump-center-1 eq 1
|
|
<test logic="OR">
|
|
/controls/switches/fuel/center-mode eq 0
|
|
<test logic="AND">
|
|
fcs/slat-pos-deg lt 16
|
|
/systems/fuel/pumps/center-control-low-level ne 1
|
|
propulsion/tank[1]/contents-lbs lt 11420
|
|
</test>
|
|
</test>
|
|
/systems/electrical/bus/ac-1 ge 110
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/fuel/pumps/center-pump-2-operate">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/switches/fuel/pump-center-3 eq 1
|
|
<test logic="OR">
|
|
/controls/switches/fuel/center-mode eq 0
|
|
<test logic="AND">
|
|
fcs/slat-pos-deg lt 16
|
|
/systems/fuel/pumps/center-control-low-level ne 1
|
|
propulsion/tank[3]/contents-lbs lt 11420
|
|
</test>
|
|
</test>
|
|
/systems/electrical/bus/ac-2 ge 110
|
|
</test>
|
|
</switch>
|
|
|
|
<actuator name="/systems/fuel/pumps/center-control-low-level">
|
|
<description>Timer for the Fuel Center pumps</description>
|
|
<input>/systems/fuel/quantity/center-low</input>
|
|
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
|
|
<rate_limit sense="incr">0.00333</rate_limit> <!-- 300 seconds -->
|
|
</actuator>
|
|
|
|
<!-- Valves -->
|
|
<switch name="/systems/fuel/valves/outer-inner-transfer-valve-1-cmd">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/fuel/valves/intercell-transfer-valve-1-cmd eq 1
|
|
/systems/fuel/refuel/refuelling eq 0
|
|
</test>
|
|
<test value="1">
|
|
/systems/fuel/quantity/left-wing-inner-low eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/fuel/valves/outer-inner-transfer-valve-1-power">
|
|
<default value="0"/>
|
|
<test value="0.333">
|
|
/systems/electrical/bus/dc-ess-shed ge 25
|
|
</test>
|
|
</switch>
|
|
|
|
<actuator name="/systems/fuel/valves/outer-inner-transfer-valve-1">
|
|
<input>/systems/fuel/valves/outer-inner-transfer-valve-1-cmd</input>
|
|
<rate_limit><property>/systems/fuel/valves/outer-inner-transfer-valve-1-power</property></rate_limit>
|
|
</actuator>
|
|
|
|
<switch name="/systems/fuel/valves/outer-inner-transfer-valve-2-cmd">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/systems/fuel/valves/intercell-transfer-valve-2-cmd eq 1
|
|
/systems/fuel/refuel/refuelling eq 0
|
|
</test>
|
|
<test value="1">
|
|
/systems/fuel/quantity/right-wing-inner-low eq 1
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/fuel/valves/outer-inner-transfer-valve-2-power">
|
|
<default value="0"/>
|
|
<test value="0.333">
|
|
/systems/electrical/bus/dc-ess-shed ge 25
|
|
</test>
|
|
</switch>
|
|
|
|
<actuator name="/systems/fuel/valves/outer-inner-transfer-valve-2">
|
|
<input>/systems/fuel/valves/outer-inner-transfer-valve-2-cmd</input>
|
|
<rate_limit><property>/systems/fuel/valves/outer-inner-transfer-valve-2-power</property></rate_limit>
|
|
</actuator>
|
|
|
|
<!-- Engine LP Valves -->
|
|
<switch name="/systems/fuel/valves/engine-1-lp-valve-cmd">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/engines/engine[0]/fire-btn eq 0
|
|
/controls/engines/engine[0]/cutoff-switch eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/fuel/valves/engine-1-lp-valve-power">
|
|
<default value="0"/>
|
|
<test logic="OR" value="1.0">
|
|
/systems/electrical/bus/dc-ess-shed ge 25
|
|
/systems/electrical/bus/dc-2 ge 25
|
|
</test>
|
|
</switch>
|
|
|
|
<actuator name="/systems/fuel/valves/engine-1-lp-valve">
|
|
<input>/systems/fuel/valves/engine-1-lp-valve-cmd</input>
|
|
<rate_limit><property>/systems/fuel/valves/engine-1-lp-valve-power</property></rate_limit>
|
|
</actuator>
|
|
|
|
<switch name="/systems/fuel/valves/engine-2-lp-valve-cmd">
|
|
<default value="0"/>
|
|
<test logic="AND" value="1">
|
|
/controls/engines/engine[1]/fire-btn eq 0
|
|
/controls/engines/engine[1]/cutoff-switch eq 0
|
|
</test>
|
|
</switch>
|
|
|
|
<switch name="/systems/fuel/valves/engine-2-lp-valve-power">
|
|
<default value="0"/>
|
|
<test logic="OR" value="1.0">
|
|
/systems/electrical/bus/dc-ess-shed ge 25
|
|
/systems/electrical/bus/dc-2 ge 25
|
|
</test>
|
|
</switch>
|
|
|
|
<actuator name="/systems/fuel/valves/engine-2-lp-valve">
|
|
<input>/systems/fuel/valves/engine-2-lp-valve-cmd</input>
|
|
<rate_limit><property>/systems/fuel/valves/engine-2-lp-valve-power</property></rate_limit>
|
|
</actuator>
|
|
</channel>
|
|
|
|
<channel name="Flow Rates">
|
|
|
|
</channel>
|
|
|
|
</system>
|