<!-- Airbus A320 FWC -->
<!-- Copyright (c) 2019 Jonathan Redpath -->
<system name="A320: FWC">
<channel name="FWC" execrate="8">
<actuator name="/ECAM/phases/timer/eng1idle-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/phases/timer/eng1idle</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.033</rate_limit> <!-- 30 seconds -->
</actuator>
<actuator name="/ECAM/phases/timer/eng2idle-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/phases/timer/eng2idle</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.033</rate_limit> <!-- 30 seconds -->
</actuator>
<actuator name="/ECAM/phases/timer/eng1or2-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/phases/timer/eng1or2</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.033</rate_limit> <!-- 30 seconds -->
</actuator>
<actuator name="/ECAM/phases/timer/to-inhibit-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/phases/timer/to-inhibit</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.33</rate_limit> <!-- 3 seconds -->
</actuator>
<actuator name="/ECAM/phases/timer/ldg-inhibit-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/phases/timer/ldg-inhibit</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.33</rate_limit> <!-- 3 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/bleed-1-fault-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/timer/bleed-1-fault</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/bleed-2-fault-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/timer/bleed-2-fault</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/apu-fault-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/apu-bleed-fault</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/xbleed-fault-output">
<description>Timer for the ECAM system</description>
<input>/systems/pneumatics/warnings/crossbleed-disag</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/prv-1-not-shut-apu-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/prv-1-not-shut-apu</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 second -->
</actuator>
<actuator name="/ECAM/warnings/timer/prv-2-not-shut-apu-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/prv-2-not-shut-apu</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 second -->
</actuator>
<actuator name="/ECAM/warnings/timer/prv-1-not-shut-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/prv-1-not-shut</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 second -->
</actuator>
<actuator name="/ECAM/warnings/timer/prv-2-not-shut-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/prv-2-not-shut</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">1</rate_limit> <!-- 1 second -->
</actuator>
<actuator name="/ECAM/warnings/timer/bleed-1-and-2-low-temp-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/timer/bleed-1-and-2-low-temp</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.00185185</rate_limit> <!-- 540 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/bleed-1-low-temp-output">
<description>Timer for the ECAM system</description>
<input>/systems/pneumatics/warnings/lowtemp-1-mem</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.016666</rate_limit> <!-- 60 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/bleed-2-low-temp-output">
<description>Timer for the ECAM system</description>
<input>/systems/pneumatics/warnings/lowtemp-2-mem</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.016666</rate_limit> <!-- 60 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/bleed-1-off-60-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/bleed-1-off-60</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.016666</rate_limit> <!-- 60 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/bleed-2-off-60-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/bleed-2-off-60</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.016666</rate_limit> <!-- 60 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/bleed-1-off-5-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/bleed-1-off-5</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/bleed-2-off-5-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/bleed-2-off-5</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/eng-aice-1-open-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/eng-aice-1-open</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/eng-aice-2-open-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/eng-aice-2-open</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/eng-aice-1-closed-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/eng-aice-1-closed</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/eng-aice-2-closed-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/eng-aice-2-closed</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/wing-anti-ice-flipflop-set">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/wing-anti-ice-flipflop-set-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.0285714</rate_limit> <!-- 35 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/phase-1">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/timer/phase-1-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.5</rate_limit> <!-- 2 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/wing-anti-ice-25">
<description>Timer for the ECAM system</description>
<input>/controls/ice-protection/wing</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.04</rate_limit> <!-- 25 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/wing-anti-ice-left-closed-set">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/wing-anti-ice-left-closed-set-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.066666</rate_limit> <!-- 15 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/wing-anti-ice-right-closed-set">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/wing-anti-ice-right-closed-set-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.066666</rate_limit> <!-- 15 seconds -->
</actuator>
<actuator name="/ECAM/warnings/logic/proc-wai-shutdown-output">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/proc-wai-shutdown-flipflop</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/wing-hi-pr-left">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/wing-hi-pr-left-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.025</rate_limit> <!-- 40 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/wing-hi-pr-right">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/wing-hi-pr-right-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.025</rate_limit> <!-- 40 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/cranking-35-sec">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/cranking-35-sec-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.028571</rate_limit> <!-- 35 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-1-fault-closed">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-1-fault-closed-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-2-fault-closed">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-2-fault-closed-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-1-disagree">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-1-disagree-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-2-disagree">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-2-fault-closed-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/ignition">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/ignition</input>
<rate_limit sense="incr">100</rate_limit> <!-- Instant -->
<rate_limit sense="decr">0.028571</rate_limit> <!-- 35 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-1-fault-5">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-1-fault-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.20</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-2-fault-5">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-2-fault-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.20</rate_limit> <!-- 5 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-1-fault-2">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-1-fault-warning-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.50</rate_limit> <!-- 2 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-2-fault-2">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-2-fault-warning-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.50</rate_limit> <!-- 2 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-1-off">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-1-off-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.0166666</rate_limit> <!-- 60 seconds -->
</actuator>
<actuator name="/ECAM/warnings/timer/pack-2-off">
<description>Timer for the ECAM system</description>
<input>/ECAM/warnings/logic/pack-2-off-input</input>
<rate_limit sense="decr">100</rate_limit> <!-- Instant -->
<rate_limit sense="incr">0.0166666</rate_limit> <!-- 60 seconds -->
</actuator>
</channel>
<channel name="ECAM">
<switch name="/ECAM/warnings/logic/apu-bleed-fault">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/systems/electrical/bus/dc-2 ge 25
/systems/electrical/relay/dc-ess-feed-bat/contact-pos eq 1
</test>
<test logic="OR">
<test logic="AND">
/systems/apu/available eq 1
/controls/apu/master eq 1
/controls/pneumatics/switches/apu eq 0
/systems/pneumatics/valves/apu-bleed-valve ne 0
</test>
<test logic="AND">
/systems/apu/available eq 1
/controls/apu/master eq 1
/controls/pneumatics/switches/apu eq 1
/systems/pneumatics/valves/apu-bleed-valve ne 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/prv-1-not-shut-apu">
<default value="0"/>
<test logic="AND" value="1">
/systems/apu/available eq 1
/controls/pneumatics/switches/apu eq 1
/systems/pneumatics/valves/engine-1-prv-valve-disag eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/prv-2-not-shut-apu">
<default value="0"/>
<test logic="AND" value="1">
/systems/apu/available eq 1
/controls/pneumatics/switches/apu eq 1
/systems/pneumatics/valves/engine-2-prv-valve-disag eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/prv-1-not-shut-apu-reset">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/controls/pneumatics/switches/bleed-1 eq 0
/ECAM/warnings/logic/engine-1-prv-valve-falling-pulse eq 0 <!-- inverse -->
</test>
/ECAM/warning-phase eq 1
<test logic="AND">
/engines/engine[0]/state eq 3
<test logic="AND">
/ECAM/warnings/logic/apu-bleed-sw-pulse eq 1
/controls/pneumatics/switches/apu eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/prv-2-not-shut-apu-reset">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/controls/pneumatics/switches/bleed-2 eq 0
/ECAM/warnings/logic/engine-2-prv-valve-falling-pulse eq 0 <!-- inverse -->
</test>
/ECAM/warning-phase eq 1
<test logic="AND">
/engines/engine[1]/state eq 3
<test logic="AND">
/ECAM/warnings/logic/apu-bleed-sw-pulse eq 1
/controls/pneumatics/switches/apu eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/prv-1-not-shut">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/prv-1-not-shut-apu-flipflop-output eq 1
<test logic="AND">
/engines/engine[0]/state ne 3
/systems/pneumatics/valves/engine-1-prv-valve-disag eq 1
</test>
<test logic="AND">
/systems/pneumatics/valves/starter-valve-1 ne 0
/systems/pneumatics/valves/engine-1-prv-valve-disag eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/prv-2-not-shut">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/prv-2-not-shut-apu-flipflop-output eq 1
<test logic="AND">
/engines/engine[1]/state ne 3
/systems/pneumatics/valves/engine-2-prv-valve-disag eq 1
</test>
<test logic="AND">
/systems/pneumatics/valves/starter-valve-2 ne 0
/systems/pneumatics/valves/engine-2-prv-valve-disag eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/crossbleed-fault">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/timer/xbleed-fault-output eq 1
<test logic="AND">
/ECAM/warnings/timer/xbleed-fault-output-10 eq 1
/ECAM/warnings/timer/xbleed-fault-output-15 eq 0
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/crossbleed-wai">
<default value="0"/>
<test logic="AND" value="1">
/systems/apu/available eq 1
/controls/pneumatics/switches/apu eq 1
/systems/pneumatics/valves/engine-1-prv-valve eq 0
/systems/pneumatics/valves/engine-2-prv-valve eq 0
/systems/pneumatics/warnings/crossbleed-disag-open eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-low-temp-reset">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/controls/ice-protection/wing eq 0
/ECAM/warnings/logic/wai-falling-pulse eq 0
</test>
/gear/gear[1]/wow eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-not-avail">
<default value="0"/>
<test logic="OR" value="1">
/engines/engine[0]/state ne 3
/controls/pneumatics/switches/bleed-1 eq 0
/systems/pneumatics/valves/engine-1-prv-valve-autoclose-cmd eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-not-avail">
<default value="0"/>
<test logic="OR" value="1">
/engines/engine[1]/state ne 3
/controls/pneumatics/switches/bleed-2 eq 0
/systems/pneumatics/valves/engine-2-prv-valve-autoclose-cmd eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-or-2-not-avail">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/bleed-1-not-avail eq 1
/ECAM/warnings/logic/bleed-2-not-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-apu-is-in-use">
<default value="0"/>
<test logic="AND" value="1">
/systems/apu/available eq 1
/controls/pneumatics/switches/apu eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-avail">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/bleed-1-not-avail eq 0
/ECAM/warnings/logic/bleed-apu-is-in-use eq 1
<test logic="AND">
/systems/pneumatics/valves/crossbleed-valve eq 1
/ECAM/warnings/logic/bleed-2-not-avail eq 0
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-avail">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/bleed-2-not-avail eq 0
<test logic="AND">
/systems/pneumatics/valves/crossbleed-valve eq 1
<test logic="OR">
/ECAM/warnings/logic/bleed-1-not-avail eq 0
/ECAM/warnings/logic/bleed-apu-is-in-use eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-wai-avail">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-apu-is-in-use eq 0
/ECAM/warnings/logic/bleed-1-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-wai-avail">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-apu-is-in-use eq 0
/ECAM/warnings/logic/bleed-2-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wai-on">
<default value="0"/>
<test logic="AND" value="1">
/controls/ice-protection/wing eq 1
<test logic="OR">
/systems/pneumatics/valves/wing-ice-1 eq 1
/systems/pneumatics/valves/wing-ice-2 eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-lo-temp-xbleed">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-2-wai-avail eq 1 <!-- deliberate -->
/systems/pneumatics/valves/crossbleed-valve eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-lo-temp-bleed">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-2-wai-avail eq 1
/controls/pneumatics/switches/bleed-1 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-lo-temp-pack">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-2-wai-avail eq 1
/controls/pneumatics/switches/pack-1 eq 1
/controls/pneumatics/switches/pack-2 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-lo-temp-unsucc">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/bleed-2-wai-avail eq 0
/ECAM/warnings/logic/bleed-1-lo-temp-xbleed eq 1
/ECAM/warnings/logic/bleed-1-lo-temp-bleed eq 1
/ECAM/warnings/logic/bleed-1-lo-temp-pack eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-lo-temp-xbleed">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-1-wai-avail eq 1 <!-- deliberate -->
/systems/pneumatics/valves/crossbleed-valve eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-lo-temp-bleed">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-1-wai-avail eq 1
/controls/pneumatics/switches/bleed-2 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-lo-temp-pack">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/bleed-1-wai-avail eq 1
/controls/pneumatics/switches/pack-1 eq 1
/controls/pneumatics/switches/pack-2 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-off-60">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/warnings/lowtemp-1-mem eq 0
/ECAM/warning-phase eq 6
/controls/pneumatics/switches/bleed-1 eq 0
/ECAM/warnings/logic/prv-1-not-shut eq 0
/ECAM/warnings/logic/bleed-1-off-flipflop eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-off-5">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/warnings/lowtemp-1-mem eq 0
/ECAM/warning-phase eq 2
/controls/pneumatics/switches/bleed-1 eq 0
/ECAM/warnings/logic/prv-1-not-shut eq 0
/ECAM/warnings/logic/bleed-1-off-flipflop eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-off-flipflop-set">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/valves/engine-1-prv-valve-disag eq 1
/controls/pneumatics/switches/bleed-1 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-1-off-flipflop-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 3
/ECAM/warning-phase eq 7
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-off-60">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/warnings/lowtemp-2-mem eq 0
/ECAM/warning-phase eq 6
/controls/pneumatics/switches/bleed-2 eq 0
/ECAM/warnings/logic/prv-2-not-shut eq 0
/ECAM/warnings/logic/bleed-2-off-flipflop eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-off-5">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/warnings/lowtemp-2-mem eq 0
/ECAM/warning-phase eq 2
/controls/pneumatics/switches/bleed-2 eq 0
/ECAM/warnings/logic/prv-2-not-shut eq 0
/ECAM/warnings/logic/bleed-2-off-flipflop eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-off-flipflop-set">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/valves/engine-2-prv-valve-disag eq 1
/controls/pneumatics/switches/bleed-2 eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/bleed-2-off-flipflop-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 3
/ECAM/warning-phase eq 7
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng-aice-1-open">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/phases/timer/eng1idle-output ne 0
/systems/electrical/bus/dc-1 ge 25
/controls/ice-protection/lengfault eq 1
/controls/ice-protection/leng eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng-aice-2-open">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/phases/timer/eng2idle-output ne 0
/systems/electrical/bus/dc-2 ge 25
/controls/ice-protection/rengfault eq 1
/controls/ice-protection/reng eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng-aice-1-closed">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/phases/timer/eng1idle-output ne 0
/controls/ice-protection/lengfault eq 1
/controls/ice-protection/leng eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/eng-aice-2-closed">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/phases/timer/eng2idle-output ne 0
/controls/ice-protection/rengfault eq 1
/controls/ice-protection/reng eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wai-ground-pulse-set">
<default value="0"/>
<test logic="AND" value="1">
/gear/gear[1]/wow eq 0
/controls/ice-protection/wing eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-left-closed-set-input">
<default value="0"/>
<test logic="AND" value="1">
/controls/ice-protection/wing eq 1
/ECAM/warnings/logic/bleed-1-avail eq 1
<test logic="OR">
/systems/pneumatics/valves/wing-ice-1 eq 0
/systems/pneumatics/psi/engine-1-psi lt 13
</test>
<test logic="OR">
<test logic="AND">
/ECAM/warnings/logic/wai-ground-pulse-set eq 1
</test>
<test logic="AND">
/gear/gear[1]/wow eq 1
/ECAM/warnings/timer/wing-anti-ice-25 ne 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-right-closed-set-input">
<default value="0"/>
<test logic="AND" value="1">
/controls/ice-protection/wing eq 1
/ECAM/warnings/logic/bleed-2-avail eq 1
<test logic="OR">
/systems/pneumatics/valves/wing-ice-2 eq 0
/systems/pneumatics/psi/engine-2-psi lt 13
</test>
<test logic="OR">
<test logic="AND">
/ECAM/warnings/logic/wai-ground-pulse-set eq 1
</test>
<test logic="AND">
/gear/gear[1]/wow eq 1
/ECAM/warnings/timer/wing-anti-ice-25 ne 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/timer/phase-1-input">
<default value="0"/>
<test value="1">
/ECAM/warning-phase eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-left-closed-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/timer/phase-1 eq 1
<test logic="AND">
/systems/pneumatics/valves/wing-ice-1 eq 1
/controls/ice-protection/wing eq 1
/ECAM/warnings/logic/bleed-1-avail eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-right-closed-reset">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/timer/phase-1 eq 1
<test logic="AND">
/systems/pneumatics/valves/wing-ice-2 eq 1
/controls/ice-protection/wing eq 1
/ECAM/warnings/logic/bleed-2-avail eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-flipflop-set-input">
<defualt value="0"/>
<test logic="AND" value="1">
/controls/ice-protection/wing eq 1
/gear/gear[1]/wow eq 1
/ECAM/warnings/logic/wai-on eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-flipflop-reset">
<defualt value="0"/>
<test logic="OR" value="1">
/ECAM/warning-phase eq 1
/ECAM/warning-phase eq 10
</test>
</switch>
<switch name="/ECAM/warnings/logic/proc-wai-shutdown-set">
<default value="0"/>
<test logic="AND" value="1">
/systems/pneumatics/valves/crossbleed-valve eq 0
/controls/engines/engine[0]/fire-btn eq 0
/controls/engines/engine[1]/fire-btn eq 0
/ECAM/warnings/logic/wai-ground-pulse eq 1
/ECAM/warnings/logic/wai-ground-pulse-set eq 1
<test logic="OR">
<test logic="AND">
/engines/engine[0]/state eq 3
/engines/engine[1]/state ne 3 <!-- TODO this must use ENG 1 FAIL from the ECAM warning see page 2856 of ESLD -->
</test>
<test logic="AND">
/engines/engine[0]/state ne 3
/engines/engine[1]/state eq 3
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/proc-wai-shutdown-reset">
<default value="0"/>
<test logic="OR" value="1">
/systems/pneumatics/valves/crossbleed-valve ne 0
/ECAM/warnings/logic/wai-on eq 0
<test logic="AND">
/ECAM/warnings/timer/phase-1-input eq 1
/ECAM/warnings/timer/phase-1-pulse eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-sys-fault">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/logic/proc-wai-shutdown-output eq 1
<test logic="AND">
<test logic="OR">
/ECAM/warnings/logic/wai-ground-pulse eq 0
/ECAM/warnings/logic/wai-ground-pulse-set eq 0
</test>
<test logic="OR">
/ECAM/warnings/flipflop/wing-anti-ice-left-closed eq 1
/ECAM/warnings/flipflop/wing-anti-ice-right-closed eq 1
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/wai-phase-9-pulse-input">
<default value="0"/>
<test logic="AND" value="1">
/controls/ice-protection/wing eq 1
/ECAM/warning-phase eq 9
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-gnd-fault-set">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/wing-anti-ice-flipflop-set eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-anti-ice-gnd-fault">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/flipflop/wing-anti-ice-left-closed eq 0
/ECAM/warnings/flipflop/wing-anti-ice-right-closed eq 0
<test logic="OR">
/ECAM/warnings/logic/wai-phase-9-pulse-input eq 0
/ECAM/warnings/logic/wai-phase-9-pulse eq 0
</test>
/ECAM/warnings/logic/wing-anti-ice-gnd-fault-flipflop eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-hi-pr-left-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/wai-on eq 1
/systems/pneumatics/psi/engine-1-psi gt 49 <!-- rando number -->
</test>
</switch>
<switch name="/ECAM/warnings/logic/wing-hi-pr-right-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/wai-on eq 1
/systems/pneumatics/psi/engine-2-psi gt 49
</test>
</switch>
<switch name="/ECAM/warnings/logic/phase-10-pulse-input">
<default value="0"/>
<test value="1">
/ECAM/warning-phase eq 10
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-ovht-reset">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/ECAM/warnings/logic/phase-10-pulse-input eq 1
/ECAM/warnings/logic/phase-10-pulse eq 1
</test>
<test logic="AND">
/ECAM/warnings/logic/pack-1-pulse eq 1
/controls/pneumatics/switches/pack-1 eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-2-ovht-reset">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/ECAM/warnings/logic/phase-10-pulse-input eq 1
/ECAM/warnings/logic/phase-10-pulse eq 1
</test>
<test logic="AND">
/ECAM/warnings/logic/pack-2-pulse eq 1
/controls/pneumatics/switches/pack-2 eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/cranking-35-sec-input">
<default value="0"/>
<test value="1">
/controls/engines/engine-start-switch eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-fault-closed-input">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/controls/engines/engine-start-switch eq 0
/ECAM/warnings/timer/cranking-35-sec eq 1
</test>
/controls/pneumatics/switches/pack-1 eq 1
/systems/air-conditioning/valves/flow-control-valve-1 eq 0
/systems/air-conditioning/packs/pack-1-outlet-temp lt 260 <!-- confirm -->
/ECAM/warnings/logic/bleed-1-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-2-fault-closed-input">
<default value="0"/>
<test logic="AND" value="1">
<test logic="OR">
/controls/engines/engine-start-switch eq 0
/ECAM/warnings/timer/cranking-35-sec eq 1
</test>
/controls/pneumatics/switches/pack-2 eq 1
/systems/air-conditioning/valves/flow-control-valve-2 eq 0
/systems/air-conditioning/packs/pack-2-outlet-temp lt 260 <!-- confirm -->
/ECAM/warnings/logic/bleed-2-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-disagree-input">
<default value="0"/>
<test logic="AND" value="1">
/systems/air-conditioning/warnings/pack-1-disagree eq 1
/ECAM/warnings/logic/bleed-1-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-2-disagree-input">
<default value="0"/>
<test logic="AND" value="1">
/systems/air-conditioning/warnings/pack-2-disagree eq 1
/ECAM/warnings/logic/bleed-2-avail eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/ignition">
<default value="0"/>
<test logic="OR" value="1">
/systems/pneumatics/valves/starter-valve-1 ne 0
/systems/pneumatics/valves/starter-valve-2 ne 0
/controls/engines/engine-start-switch eq 2
/engines/engine[0]/state eq 1
/engines/engine[0]/state eq 2
/engines/engine[1]/state eq 1
/engines/engine[1]/state eq 2
</test>
</switch>
<switch name="/ECAM/warnings/logic/inhibit-pack-1-fault">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/timer/ignition eq 1
/ECAM/warnings/logic/ignition eq 1
<test logic="AND">
/controls/pneumatics/switches/pack-1 eq 0
/ECAM/warning-phase eq 2
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/inhibit-pack-2-fault">
<default value="0"/>
<test logic="OR" value="1">
/ECAM/warnings/timer/ignition eq 1
/ECAM/warnings/logic/ignition eq 1
<test logic="AND">
/controls/pneumatics/switches/pack-2 eq 0
/ECAM/warning-phase eq 2
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-fault-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/inhibit-pack-1-fault eq 0
<test logic="OR">
/ECAM/warnings/timer/pack-1-fault-closed eq 1
/ECAM/warnings/timer/pack-1-disagree eq 1
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-2-fault-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/logic/inhibit-pack-2-fault eq 0
<test logic="OR">
/ECAM/warnings/timer/pack-2-fault-closed eq 1
/ECAM/warnings/timer/pack-2-disagree eq 1
</test>
</test>
</switch>
<switch name="/ECAM/phases/monostable/phase-6-180">
<default value="0"/>
<test value="1">
/ECAM/warning-phase eq 6
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-2-fault">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/controls/pneumatics/switches/pack-2 eq 0
<test logic="OR">
/ECAM/warnings/timer/pack-1-fault-5 eq 1
/systems/air-conditioning/warnings/pack-1-ovht eq 1
</test>
</test>
<test logic="AND">
/controls/pneumatics/switches/pack-1 eq 0
<test logic="OR">
/ECAM/warnings/timer/pack-2-fault-5 eq 1
/systems/air-conditioning/warnings/pack-2-ovht eq 1
</test>
</test>
<test logic="AND">
/controls/pneumatics/switches/pack-1 eq 0
/controls/pneumatics/switches/pack-2 eq 0
<test logic="AND">
/ECAM/warning-phase ne 1
/ECAM/warning-phase ne 2
/ECAM/warning-phase ne 10
<test logic="OR">
/ECAM/phases/monostable/phase-6-180 eq 0
/ECAM/phases/monostable/phase-6-180-pulse eq 0
</test>
</test>
</test>
</test>
</switch>
<switch name="/ECAM/warnings/logic/reset-pack-1-switch-cmd">
<default value="0"/>
<test logic="AND" value="1">
/controls/pneumatics/switches/pack-1 eq 0
/ECAM/warnings/timer/pack-1-fault-5 eq 0
/ECAM/warnings/flipflop/pack-1-ovht eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/reset-pack-2-switch-cmd">
<default value="0"/>
<test logic="AND" value="1">
/controls/pneumatics/switches/pack-2 eq 0
/ECAM/warnings/timer/pack-2-fault-5 eq 0
/ECAM/warnings/flipflop/pack-2-ovht eq 1
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-fault-warning-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/timer/pack-1-fault-5 eq 1
/ECAM/warnings/logic/pack-1-2-fault eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-2-fault-warning-input">
<default value="0"/>
<test logic="AND" value="1">
/ECAM/warnings/timer/pack-2-fault-5 eq 1
/ECAM/warnings/logic/pack-1-2-fault eq 0
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-1-off-input">
<default value="0"/>
<test logic="AND" value="1">
/controls/pneumatics/switches/pack-1 eq 0
/ECAM/warnings/flipflop/pack-1-ovht eq 0
/ECAM/warnings/flipflop/pack-1-off eq 0
/ECAM/warnings/logic/bleed-1-low-temp-flipflop-output eq 0
/ECAM/warnings/logic/bleed-1-avail eq 1
/ECAM/warning-phase eq 6
<!-- TODO NOT HOT AIR VALVE STUCK OPEN OR OVHT -->
</test>
</switch>
<switch name="/ECAM/warnings/logic/pack-2-off-input">
<default value="0"/>
<test logic="AND" value="1">
/controls/pneumatics/switches/pack-2 eq 0
/ECAM/warnings/flipflop/pack-2-ovht eq 0
/ECAM/warnings/flipflop/pack-2-off eq 0
/ECAM/warnings/logic/bleed-2-low-temp-flipflop-output eq 0
/ECAM/warnings/logic/bleed-2-avail eq 1
/ECAM/warning-phase eq 6
<!-- TODO NOT HOT AIR VALVE STUCK OPEN OR OVHT -->
</test>
</switch>
</channel>
</system>