<!-- Copyright (c) 2019 Jonathan Redpath (legoboyvdlp) -->

<system name="A320: Lights">

	<channel name="Lights">
		<switch name="/controls/lighting/reading-light-tied">
			<default value="0" />
			<test value="/controls/lighting/main-flood-knb">
				/systems/electrical/bus/dc-1 gt 25
			</test>
		</switch>
		
		<switch name="/controls/lighting/panel-light-tied">
			<default value="0" />
			<test logic="OR" value="/controls/lighting/main-flood-knb">
				/systems/electrical/bus/dc-ess gt 25
				/systems/electrical/bus/dc-1 gt 25
			</test>
		</switch>
		
		<switch name="/controls/lighting/pedestal-light-tied">
			<default value="0" />
			<test value="/controls/lighting/ped-flood-knb">
				/systems/electrical/bus/dc-1 gt 25
			</test>
		</switch>
		
		<switch name="/controls/lighting/fcu-panel-norm-tied">
			<default value="0" />
			<test value="/controls/lighting/fcu-panel-knb">
				/systems/electrical/bus/ac-1 gt 25
			</test>
		</switch>
		
		<switch name="/controls/lighting/main-panel-norm-tied">
			<default value="0" />
			<test value="/controls/lighting/main-panel-knb">
				/systems/electrical/bus/ac-1 gt 25
			</test>
		</switch>
		
		<switch name="/controls/lighting/overhead-panel-norm-tied">
			<default value="0" />
			<test value="/controls/lighting/overhead-panel-knb">
				/systems/electrical/bus/ac-1 gt 25
			</test>
		</switch>
		
		<switch name="/controls/lighting/annunciator-lights-tied">
			<default value="0" />
			<test logic="OR" value="1"> <!-- TODO: add static inverter as a source, also dc-2 switching -->
				/systems/electrical/bus/ac-1 gt 110
				/systems/electrical/bus/ac-2 gt 110
				/systems/electrical/bus/dc-2 gt 25
			</test>
		</switch>
	</channel>

</system>