<?xml version="1.0"?>

<!-- Airbus A320 FWC -->
<!-- Copyright (c) 2019 Jonathan Redpath -->

<system name="A320: FWC">

	<channel name="FWC" execrate="8">
		
		<actuator name="/ECAM/phases/timer/eng1idle-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/phases/timer/eng1idle</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.033</rate_limit> <!-- 30 seconds -->
        </actuator>
		
		<actuator name="/ECAM/phases/timer/eng2idle-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/phases/timer/eng2idle</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.033</rate_limit> <!-- 30 seconds -->
        </actuator>
		
		<actuator name="/ECAM/phases/timer/eng1or2-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/phases/timer/eng1or2</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.033</rate_limit> <!-- 30 seconds -->
        </actuator>
		
		<actuator name="/ECAM/phases/timer/to-inhibit-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/phases/timer/to-inhibit</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.33</rate_limit> <!-- 3 seconds -->
        </actuator>
		
		<actuator name="/ECAM/phases/timer/ldg-inhibit-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/phases/timer/ldg-inhibit</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.33</rate_limit> <!-- 3 seconds -->
        </actuator>
		
		<actuator name="/ECAM/warnings/timer/bleed-1-fault-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/warnings/timer/bleed-1-fault</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
        </actuator>
		
		<actuator name="/ECAM/warnings/timer/bleed-2-fault-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/warnings/timer/bleed-2-fault</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
        </actuator>
		
		<actuator name="/ECAM/warnings/timer/apu-fault-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/warnings/logic/apu-bleed-fault</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
        </actuator>
		
		<actuator name="/ECAM/warnings/timer/xbleed-fault-output">
            <description>Timer for the ECAM system</description>
            <input>/systems/pneumatics/warnings/crossbleed-disag</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
        </actuator>
		
		<actuator name="/ECAM/warnings/timer/prv-1-not-shut-apu-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/warnings/logic/prv-1-not-shut-apu</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">1</rate_limit> <!-- 1 second -->
        </actuator>
		
		<actuator name="/ECAM/warnings/timer/prv-2-not-shut-apu-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/warnings/logic/prv-2-not-shut-apu</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">1</rate_limit> <!-- 1 second -->
        </actuator>
		
		<actuator name="/ECAM/warnings/timer/prv-1-not-shut-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/warnings/logic/prv-1-not-shut</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">1</rate_limit> <!-- 1 second -->
        </actuator>
		
		<actuator name="/ECAM/warnings/timer/prv-2-not-shut-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/warnings/logic/prv-2-not-shut</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">1</rate_limit> <!-- 1 second -->
        </actuator>
		
		<actuator name="/ECAM/warnings/timer/bleed-1-and-2-low-temp-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/warnings/timer/bleed-1-and-2-low-temp</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.00185185</rate_limit> <!-- 540 seconds -->
        </actuator>
		
		<actuator name="/ECAM/warnings/timer/bleed-1-low-temp-output">
            <description>Timer for the ECAM system</description>
            <input>/systems/pneumatics/warnings/lowtemp-1-mem</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.016666</rate_limit> <!-- 60 seconds -->
        </actuator>
		
		<actuator name="/ECAM/warnings/timer/bleed-2-low-temp-output">
            <description>Timer for the ECAM system</description>
            <input>/systems/pneumatics/warnings/lowtemp-2-mem</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.016666</rate_limit> <!-- 60 seconds -->
        </actuator>
		
		<actuator name="/ECAM/warnings/logic/bleed-1-off-60-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/warnings/logic/bleed-1-off-60</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.016666</rate_limit> <!-- 60 seconds -->
        </actuator>
		
		<actuator name="/ECAM/warnings/logic/bleed-2-off-60-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/warnings/logic/bleed-2-off-60</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.016666</rate_limit> <!-- 60 seconds -->
        </actuator>
		
		<actuator name="/ECAM/warnings/logic/bleed-1-off-5-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/warnings/logic/bleed-1-off-5</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
        </actuator>
		
		<actuator name="/ECAM/warnings/timer/bleed-2-off-5-output">
            <description>Timer for the ECAM system</description>
            <input>/ECAM/warnings/logic/bleed-2-off-5</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
        </actuator>
		
		<actuator name="/ECAM/warnings/timer/eng-aice-1-open-output">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/eng-aice-1-open</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/eng-aice-2-open-output">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/eng-aice-2-open</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/eng-aice-1-closed-output">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/eng-aice-1-closed</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/eng-aice-2-closed-output">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/eng-aice-2-closed</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/logic/wing-anti-ice-flipflop-set">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/wing-anti-ice-flipflop-set-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.0285714</rate_limit> <!-- 35 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/phase-1">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/timer/phase-1-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.5</rate_limit> <!-- 2 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/wing-anti-ice-25">
            <description>Timer for the ECAM system</description>
			<input>/controls/ice-protection/wing</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.04</rate_limit> <!-- 25 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/logic/wing-anti-ice-left-closed-set">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/wing-anti-ice-left-closed-set-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.066666</rate_limit> <!-- 15 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/logic/wing-anti-ice-right-closed-set">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/wing-anti-ice-right-closed-set-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.066666</rate_limit> <!-- 15 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/logic/proc-wai-shutdown-output">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/proc-wai-shutdown-flipflop</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/wing-hi-pr-left">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/wing-hi-pr-left-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.025</rate_limit> <!-- 40 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/wing-hi-pr-right">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/wing-hi-pr-right-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.025</rate_limit> <!-- 40 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/cranking-35-sec">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/cranking-35-sec-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.028571</rate_limit> <!-- 35 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/pack-1-fault-closed">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/pack-1-fault-closed-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/pack-2-fault-closed">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/pack-2-fault-closed-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/pack-1-disagree">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/pack-1-disagree-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/pack-2-disagree">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/pack-2-disagree-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/ignition">
            <description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/ignition</input>
            <rate_limit sense="incr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="decr">0.028571</rate_limit> <!-- 35 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/pack-1-fault-5">
			<description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/pack-1-fault-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.20</rate_limit> <!-- 5 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/pack-2-fault-5">
			<description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/pack-2-fault-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.20</rate_limit> <!-- 5 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/pack-1-fault-2">
			<description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/pack-1-fault-warning-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.50</rate_limit> <!-- 2 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/pack-2-fault-2">
			<description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/pack-2-fault-warning-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.50</rate_limit> <!-- 2 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/pack-1-off">
			<description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/pack-1-off-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.0166666</rate_limit> <!-- 60 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/pack-2-off">
			<description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/pack-2-off-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.0166666</rate_limit> <!-- 60 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/trim-air-fault">
			<description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/trim-air-fault-input</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/yaw-damper-1-fault">
			<description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/yaw-damper-1-fault</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/yaw-damper-2-fault">
			<description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/yaw-damper-2-fault</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">0.2</rate_limit> <!-- 5 seconds -->
		</actuator>
		
		<actuator name="/ECAM/warnings/timer/nav-gpws-terr-fault">
			<description>Timer for the ECAM system</description>
			<input>/ECAM/warnings/logic/nav-gpws-terr-fault</input>
            <rate_limit sense="decr">100</rate_limit> <!-- Instant -->
            <rate_limit sense="incr">1.0</rate_limit> <!-- 1 second -->
		</actuator>
	</channel>
	
	<channel name="ECAM" execrate="8">
		
		<switch name="/ECAM/warnings/logic/apu-bleed-fault">
			<default value="0"/>
			<test logic="AND" value="1">
				<test logic="OR">
					/systems/electrical/bus/dc-2 ge 25
					/systems/electrical/relay/dc-ess-feed-bat/contact-pos eq 1
				</test>
				<test logic="OR">
					<test logic="AND">
						/systems/apu/available eq 1
						/controls/apu/master eq 1
						/controls/pneumatics/switches/apu eq 0
						/systems/pneumatics/valves/apu-bleed-valve ne 0
					</test>
					<test logic="AND">
						/systems/apu/available eq 1
						/controls/apu/master eq 1
						/controls/pneumatics/switches/apu eq 1
						/systems/pneumatics/valves/apu-bleed-valve ne 1
					</test>
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/prv-1-not-shut-apu">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/apu/available eq 1
				/controls/pneumatics/switches/apu eq 1
				/systems/pneumatics/valves/engine-1-prv-valve-disag eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/prv-2-not-shut-apu">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/apu/available eq 1
				/controls/pneumatics/switches/apu eq 1
				/systems/pneumatics/valves/engine-2-prv-valve-disag eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/prv-1-not-shut-apu-reset">
			<default value="0"/>
			<test logic="OR" value="1">
				<test logic="AND">
					/controls/pneumatics/switches/bleed-1 eq 0
					/ECAM/warnings/logic/engine-1-prv-valve-falling-pulse eq 0 <!-- inverse -->
				</test>
				/ECAM/warning-phase eq 1
				<test logic="AND">
					/engines/engine[0]/state eq 3
					<test logic="AND">
						/ECAM/warnings/logic/apu-bleed-sw-pulse eq 1
						/controls/pneumatics/switches/apu eq 1
					</test>
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/prv-2-not-shut-apu-reset">
			<default value="0"/>
			<test logic="OR" value="1">
				<test logic="AND">
					/controls/pneumatics/switches/bleed-2 eq 0
					/ECAM/warnings/logic/engine-2-prv-valve-falling-pulse eq 0 <!-- inverse -->
				</test>
				/ECAM/warning-phase eq 1
				<test logic="AND">
					/engines/engine[1]/state eq 3
					<test logic="AND">
						/ECAM/warnings/logic/apu-bleed-sw-pulse eq 1
						/controls/pneumatics/switches/apu eq 1
					</test>
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/prv-1-not-shut">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warnings/logic/prv-1-not-shut-apu-flipflop-output eq 1
				<test logic="AND">
					/engines/engine[0]/state ne 3
					/systems/pneumatics/valves/engine-1-prv-valve-disag eq 1
				</test>
				<test logic="AND">
					/systems/pneumatics/valves/starter-valve-1 ne 0
					/systems/pneumatics/valves/engine-1-prv-valve-disag eq 1
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/prv-2-not-shut">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warnings/logic/prv-2-not-shut-apu-flipflop-output eq 1
				<test logic="AND">
					/engines/engine[1]/state ne 3
					/systems/pneumatics/valves/engine-2-prv-valve-disag eq 1
				</test>
				<test logic="AND">
					/systems/pneumatics/valves/starter-valve-2 ne 0
					/systems/pneumatics/valves/engine-2-prv-valve-disag eq 1
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/crossbleed-fault">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warnings/timer/xbleed-fault-output eq 1
				<test logic="AND">
					/ECAM/warnings/timer/xbleed-fault-output-10 eq 1
					/ECAM/warnings/timer/xbleed-fault-output-15 eq 0
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/crossbleed-wai">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/apu/available eq 1
				/controls/pneumatics/switches/apu eq 1
				/systems/pneumatics/valves/engine-1-prv-valve eq 0
				/systems/pneumatics/valves/engine-2-prv-valve eq 0
				/systems/pneumatics/warnings/crossbleed-disag-open eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-low-temp-reset">
			<default value="0"/>
			<test logic="OR" value="1">
				<test logic="AND">
					/controls/ice-protection/wing eq 0
					/ECAM/warnings/logic/wai-falling-pulse eq 0
				</test>
				/gear/gear[1]/wow eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-1-not-avail">
			<default value="0"/>
			<test logic="OR" value="1">
				/engines/engine[0]/state ne 3
				/controls/pneumatics/switches/bleed-1 eq 0
				/systems/pneumatics/valves/engine-1-prv-valve-autoclose-cmd eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-2-not-avail">
			<default value="0"/>
			<test logic="OR" value="1">
				/engines/engine[1]/state ne 3
				/controls/pneumatics/switches/bleed-2 eq 0
				/systems/pneumatics/valves/engine-2-prv-valve-autoclose-cmd eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-1-or-2-not-avail">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warnings/logic/bleed-1-not-avail eq 1
				/ECAM/warnings/logic/bleed-2-not-avail eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-apu-is-in-use">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/apu/available eq 1
				/controls/pneumatics/switches/apu eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-1-avail">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warnings/logic/bleed-1-not-avail eq 0
				/ECAM/warnings/logic/bleed-apu-is-in-use eq 1
				<test logic="AND">
					/systems/pneumatics/valves/crossbleed-valve eq 1
					/ECAM/warnings/logic/bleed-2-not-avail eq 0
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-2-avail">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warnings/logic/bleed-2-not-avail eq 0
				<test logic="AND">
					/systems/pneumatics/valves/crossbleed-valve eq 1
					<test logic="OR">
						/ECAM/warnings/logic/bleed-1-not-avail eq 0
						/ECAM/warnings/logic/bleed-apu-is-in-use eq 1
					</test>
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-1-wai-avail">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/bleed-apu-is-in-use eq 0
				/ECAM/warnings/logic/bleed-1-avail eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-2-wai-avail">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/bleed-apu-is-in-use eq 0
				/ECAM/warnings/logic/bleed-2-avail eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wai-on">
			<default value="0"/>
			<test logic="AND" value="1">
				/controls/ice-protection/wing eq 1
				<test logic="OR">
					/systems/pneumatics/valves/wing-ice-1 eq 1
					/systems/pneumatics/valves/wing-ice-2 eq 1
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-1-lo-temp-xbleed">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/bleed-2-wai-avail eq 1  <!-- deliberate -->
				/systems/pneumatics/valves/crossbleed-valve eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-1-lo-temp-bleed">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/bleed-2-wai-avail eq 1
				/controls/pneumatics/switches/bleed-1 eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-1-lo-temp-pack">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/bleed-2-wai-avail eq 1
				/controls/pneumatics/switches/pack-1 eq 1
				/controls/pneumatics/switches/pack-2 eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-1-lo-temp-unsucc">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warnings/logic/bleed-2-wai-avail eq 0
				/ECAM/warnings/logic/bleed-1-lo-temp-xbleed eq 1
				/ECAM/warnings/logic/bleed-1-lo-temp-bleed eq 1
				/ECAM/warnings/logic/bleed-1-lo-temp-pack eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-2-lo-temp-xbleed">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/bleed-1-wai-avail eq 1 <!-- deliberate -->
				/systems/pneumatics/valves/crossbleed-valve eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-2-lo-temp-bleed">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/bleed-1-wai-avail eq 1
				/controls/pneumatics/switches/bleed-2 eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-2-lo-temp-pack">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/bleed-1-wai-avail eq 1
				/controls/pneumatics/switches/pack-1 eq 1
				/controls/pneumatics/switches/pack-2 eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-1-off-60">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/pneumatics/warnings/lowtemp-1-mem eq 0
				/ECAM/warning-phase eq 6
				/controls/pneumatics/switches/bleed-1 eq 0
				/ECAM/warnings/logic/prv-1-not-shut eq 0
				/ECAM/warnings/logic/bleed-1-off-flipflop eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-1-off-5">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/pneumatics/warnings/lowtemp-1-mem eq 0
				/ECAM/warning-phase eq 2
				/controls/pneumatics/switches/bleed-1 eq 0
				/ECAM/warnings/logic/prv-1-not-shut eq 0
				/ECAM/warnings/logic/bleed-1-off-flipflop eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-1-off-flipflop-set">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/pneumatics/valves/engine-1-prv-valve-disag eq 1
				/controls/pneumatics/switches/bleed-1 eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-1-off-flipflop-reset">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warning-phase eq 1
				/ECAM/warning-phase eq 3
				/ECAM/warning-phase eq 7
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-2-off-60">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/pneumatics/warnings/lowtemp-2-mem eq 0
				/ECAM/warning-phase eq 6
				/controls/pneumatics/switches/bleed-2 eq 0
				/ECAM/warnings/logic/prv-2-not-shut eq 0
				/ECAM/warnings/logic/bleed-2-off-flipflop eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-2-off-5">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/pneumatics/warnings/lowtemp-2-mem eq 0
				/ECAM/warning-phase eq 2
				/controls/pneumatics/switches/bleed-2 eq 0
				/ECAM/warnings/logic/prv-2-not-shut eq 0
				/ECAM/warnings/logic/bleed-2-off-flipflop eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-2-off-flipflop-set">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/pneumatics/valves/engine-2-prv-valve-disag eq 1
				/controls/pneumatics/switches/bleed-2 eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/bleed-2-off-flipflop-reset">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warning-phase eq 1
				/ECAM/warning-phase eq 3
				/ECAM/warning-phase eq 7
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/eng-aice-1-open">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/phases/timer/eng1idle-output ne 0
				/systems/electrical/bus/dc-1 ge 25
				/controls/ice-protection/lengfault eq 1
				/controls/ice-protection/leng eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/eng-aice-2-open">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/phases/timer/eng2idle-output ne 0
				/systems/electrical/bus/dc-2 ge 25
				/controls/ice-protection/rengfault eq 1
				/controls/ice-protection/reng eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/eng-aice-1-closed">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/phases/timer/eng1idle-output ne 0
				/controls/ice-protection/lengfault eq 1
				/controls/ice-protection/leng eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/eng-aice-2-closed">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/phases/timer/eng2idle-output ne 0
				/controls/ice-protection/rengfault eq 1
				/controls/ice-protection/reng eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wai-ground-pulse-set">
			<default value="0"/>
			<test logic="AND" value="1">
				/gear/gear[1]/wow eq 0
				/controls/ice-protection/wing eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wing-anti-ice-left-closed-set-input">
			<default value="0"/>
			<test logic="AND" value="1">
				/controls/ice-protection/wing eq 1
				/ECAM/warnings/logic/bleed-1-avail eq 1
				<test logic="OR">
					/systems/pneumatics/valves/wing-ice-1 eq 0
					/systems/pneumatics/psi/engine-1-psi lt 13
				</test>
				<test logic="OR">
					<test logic="AND">
						/ECAM/warnings/logic/wai-ground-pulse-set eq 1
					</test>
					<test logic="AND">
						/gear/gear[1]/wow eq 1
						/ECAM/warnings/timer/wing-anti-ice-25 ne 1
					</test>
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wing-anti-ice-right-closed-set-input">
			<default value="0"/>
			<test logic="AND" value="1">
				/controls/ice-protection/wing eq 1
				/ECAM/warnings/logic/bleed-2-avail eq 1
				<test logic="OR">
					/systems/pneumatics/valves/wing-ice-2 eq 0
					/systems/pneumatics/psi/engine-2-psi lt 13
				</test>
				<test logic="OR">
					<test logic="AND">
						/ECAM/warnings/logic/wai-ground-pulse-set eq 1
					</test>
					<test logic="AND">
						/gear/gear[1]/wow eq 1
						/ECAM/warnings/timer/wing-anti-ice-25 ne 1
					</test>
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/timer/phase-1-input">
			<default value="0"/>
			<test value="1">
				/ECAM/warning-phase eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wing-anti-ice-left-closed-reset">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warnings/timer/phase-1 eq 1
				<test logic="AND">
					/systems/pneumatics/valves/wing-ice-1 eq 1
					/controls/ice-protection/wing eq 1
					/ECAM/warnings/logic/bleed-1-avail eq 1
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wing-anti-ice-right-closed-reset">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warnings/timer/phase-1 eq 1
				<test logic="AND">
					/systems/pneumatics/valves/wing-ice-2 eq 1
					/controls/ice-protection/wing eq 1
					/ECAM/warnings/logic/bleed-2-avail eq 1
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wing-anti-ice-flipflop-set-input">
			<defualt value="0"/>
			<test logic="AND" value="1">
				/controls/ice-protection/wing eq 1
				/gear/gear[1]/wow eq 1
				/ECAM/warnings/logic/wai-on eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wing-anti-ice-flipflop-reset">
			<defualt value="0"/>
			<test logic="OR" value="1">
				/ECAM/warning-phase eq 1
				/ECAM/warning-phase eq 10
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/proc-wai-shutdown-set">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/pneumatics/valves/crossbleed-valve eq 0
				/controls/engines/engine[0]/fire-btn eq 0
				/controls/engines/engine[1]/fire-btn eq 0
				/ECAM/warnings/logic/wai-ground-pulse eq 1
				/ECAM/warnings/logic/wai-ground-pulse-set eq 1
				<test logic="OR">
					<test logic="AND">
						/engines/engine[0]/state eq 3
						/engines/engine[1]/state ne 3 <!-- TODO this must use ENG 1 FAIL from the ECAM warning see page 2856 of ESLD -->
					</test>
					<test logic="AND">
						/engines/engine[0]/state ne 3
						/engines/engine[1]/state eq 3
					</test>
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/proc-wai-shutdown-reset">
			<default value="0"/>
			<test logic="OR" value="1">
				/systems/pneumatics/valves/crossbleed-valve ne 0
				/ECAM/warnings/logic/wai-on eq 0
				<test logic="AND">
					/ECAM/warnings/timer/phase-1-input eq 1
					/ECAM/warnings/timer/phase-1-pulse eq 1
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wing-anti-ice-sys-fault">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warnings/logic/proc-wai-shutdown-output eq 1
				<test logic="AND">
					<test logic="OR">
						/ECAM/warnings/logic/wai-ground-pulse eq 0
						/ECAM/warnings/logic/wai-ground-pulse-set eq 0
					</test>
					<test logic="OR">
						/ECAM/warnings/flipflop/wing-anti-ice-left-closed eq 1
						/ECAM/warnings/flipflop/wing-anti-ice-right-closed eq 1
					</test>
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wai-phase-9-pulse-input">
			<default value="0"/>
			<test logic="AND" value="1">
				/controls/ice-protection/wing eq 1
				/ECAM/warning-phase eq 9
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wing-anti-ice-gnd-fault-set">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/wing-anti-ice-flipflop-set eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wing-anti-ice-gnd-fault">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/flipflop/wing-anti-ice-left-closed eq 0
				/ECAM/warnings/flipflop/wing-anti-ice-right-closed eq 0
				<test logic="OR">
					/ECAM/warnings/logic/wai-phase-9-pulse-input eq 0
					/ECAM/warnings/logic/wai-phase-9-pulse eq 0
				</test>
				/ECAM/warnings/logic/wing-anti-ice-gnd-fault-flipflop eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wing-hi-pr-left-input">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/wai-on eq 1
				/systems/pneumatics/psi/engine-1-psi gt 49 <!-- rando number -->
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/wing-hi-pr-right-input">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/wai-on eq 1
				/systems/pneumatics/psi/engine-2-psi gt 49
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/phase-10-pulse-input">
			<default value="0"/>
			<test value="1">
				/ECAM/warning-phase eq 10
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-1-ovht-reset">
			<default value="0"/>
			<test logic="OR" value="1">
				<test logic="AND">
					/ECAM/warnings/logic/phase-10-pulse-input eq 1
					/ECAM/warnings/logic/phase-10-pulse eq 1
				</test>
				<test logic="AND">
					/ECAM/warnings/logic/pack-1-pulse eq 1
					/controls/pneumatics/switches/pack-1 eq 1
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-2-ovht-reset">
			<default value="0"/>
			<test logic="OR" value="1">
				<test logic="AND">
					/ECAM/warnings/logic/phase-10-pulse-input eq 1
					/ECAM/warnings/logic/phase-10-pulse eq 1
				</test>
				<test logic="AND">
					/ECAM/warnings/logic/pack-2-pulse eq 1
					/controls/pneumatics/switches/pack-2 eq 1
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-1-off-reset">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warning-phase eq 10
				<test logic="AND">
					/ECAM/warnings/logic/pack-1-pulse eq 1
					/controls/pneumatics/switches/pack-1 eq 1
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-2-off-reset">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warning-phase eq 10
				<test logic="AND">
					/ECAM/warnings/logic/pack-2-pulse eq 1
					/controls/pneumatics/switches/pack-2 eq 1
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/cranking-35-sec-input">
			<default value="0"/>
			<test value="1">
				/controls/engines/engine-start-switch eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-1-fault-closed-input">
			<default value="0"/>
			<test logic="AND" value="1">
				<test logic="OR">
					/controls/engines/engine-start-switch eq 0
					/ECAM/warnings/timer/cranking-35-sec eq 1
				</test>
				/controls/pneumatics/switches/pack-1 eq 1
				/systems/air-conditioning/valves/flow-control-valve-1 eq 0
				/systems/air-conditioning/packs/pack-1-outlet-temp lt 260 <!-- confirm -->
				/ECAM/warnings/logic/bleed-1-avail eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-2-fault-closed-input">
			<default value="0"/>
			<test logic="AND" value="1">
				<test logic="OR">
					/controls/engines/engine-start-switch eq 0
					/ECAM/warnings/timer/cranking-35-sec eq 1
				</test>
				/controls/pneumatics/switches/pack-2 eq 1
				/systems/air-conditioning/valves/flow-control-valve-2 eq 0
				/systems/air-conditioning/packs/pack-2-outlet-temp lt 260 <!-- confirm -->
				/ECAM/warnings/logic/bleed-2-avail eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-1-disagree-input">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/air-conditioning/warnings/pack-1-disagree eq 1
				/ECAM/warnings/logic/bleed-1-avail eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-2-disagree-input">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/air-conditioning/warnings/pack-2-disagree eq 1
				/ECAM/warnings/logic/bleed-2-avail eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/ignition">
			<default value="0"/>
			<test logic="OR" value="1">
				/systems/pneumatics/valves/starter-valve-1 ne 0
				/systems/pneumatics/valves/starter-valve-2 ne 0
				/controls/engines/engine-start-switch eq 2
				/engines/engine[0]/state eq 1
				/engines/engine[0]/state eq 2
				/engines/engine[1]/state eq 1
				/engines/engine[1]/state eq 2
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/inhibit-pack-1-fault">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warnings/timer/ignition eq 1
				/ECAM/warnings/logic/ignition eq 1
				<test logic="AND">
					/controls/pneumatics/switches/pack-1 eq 0
					/ECAM/warning-phase eq 2
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/inhibit-pack-2-fault">
			<default value="0"/>
			<test logic="OR" value="1">
				/ECAM/warnings/timer/ignition eq 1
				/ECAM/warnings/logic/ignition eq 1
				<test logic="AND">
					/controls/pneumatics/switches/pack-2 eq 0
					/ECAM/warning-phase eq 2
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-1-fault-input">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/inhibit-pack-1-fault eq 0
				<test logic="OR">
					/ECAM/warnings/timer/pack-1-fault-closed eq 1
					/ECAM/warnings/timer/pack-1-disagree eq 1
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-2-fault-input">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/inhibit-pack-2-fault eq 0
				<test logic="OR">
					/ECAM/warnings/timer/pack-2-fault-closed eq 1
					/ECAM/warnings/timer/pack-2-disagree eq 1
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/phases/monostable/phase-6-180">
			<default value="0"/>
			<test value="1">
				/ECAM/warning-phase eq 6
			</test>
		</switch>
		
		<switch name="/ECAM/phases/monostable/phase-6-180-inhibit">
			<default value="0"/>
			<test value="1">
				/ECAM/phases/monostable/phase-6-180 eq 1
				/ECAM/phases/monostable/phase-6-180-pulse eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-1-2-fault">
			<default value="0"/>
			<test logic="OR" value="1">
				<test logic="AND">
					/controls/pneumatics/switches/pack-2 eq 0
					<test logic="OR">
						/ECAM/warnings/timer/pack-1-fault-5 eq 1
						/systems/air-conditioning/warnings/pack-1-ovht eq 1
					</test>
				</test>
				<test logic="AND">
					/controls/pneumatics/switches/pack-1 eq 0
					<test logic="OR">
						/ECAM/warnings/timer/pack-2-fault-5 eq 1
						/systems/air-conditioning/warnings/pack-2-ovht eq 1
					</test>
				</test>
				<test logic="AND">
					/controls/pneumatics/switches/pack-1 eq 0
					/controls/pneumatics/switches/pack-2 eq 0
					<test logic="AND">
						/ECAM/warning-phase ne 1
						/ECAM/warning-phase ne 2
						/ECAM/warning-phase ne 10
						/ECAM/phases/monostable/phase-6-180-inhibit ne 1
					</test>
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/reset-pack-1-switch-cmd">
			<default value="0"/>
			<test logic="AND" value="1">
				/controls/pneumatics/switches/pack-1 eq 0
				/ECAM/warnings/timer/pack-1-fault-5 eq 0
				/ECAM/warnings/flipflop/pack-1-ovht eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/reset-pack-2-switch-cmd">
			<default value="0"/>
			<test logic="AND" value="1">
				/controls/pneumatics/switches/pack-2 eq 0
				/ECAM/warnings/timer/pack-2-fault-5 eq 0
				/ECAM/warnings/flipflop/pack-2-ovht eq 1
			</test>
		</switch>
		
		
		<switch name="/ECAM/warnings/logic/pack-1-fault-warning-input">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/pack-1-fault-input eq 1
				/ECAM/warnings/logic/pack-1-2-fault eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-2-fault-warning-input">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/pack-2-fault-input eq 1
				/ECAM/warnings/logic/pack-1-2-fault eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-1-off-input">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/bleed-1-avail eq 1
				/ECAM/warning-phase eq 6
				/controls/pneumatics/switches/pack-1 eq 0
				/ECAM/warnings/flipflop/pack-1-ovht eq 0
				/ECAM/warnings/flipflop/pack-1-off eq 0
				/ECAM/warnings/logic/bleed-1-low-temp-flipflop-output eq 0
				<!-- TODO NOT HOT AIR VALVE STUCK OPEN OR OVHT -->
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/pack-2-off-input">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/bleed-2-avail eq 1
				/ECAM/warning-phase eq 6
				/controls/pneumatics/switches/pack-2 eq 0
				/ECAM/warnings/flipflop/pack-2-ovht eq 0
				/ECAM/warnings/flipflop/pack-2-off eq 0
				/ECAM/warnings/logic/bleed-2-low-temp-flipflop-output eq 0
				<!-- TODO NOT HOT AIR VALVE STUCK OPEN OR OVHT -->
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/trim-air-fault-inhibit">
			<default value="0"/>
			<test logic="OR" value="1">
				/systems/electrical/bus/ac-ess lt 110
				<test logic="AND">
					<test logic="OR">
						/ECAM/warning-phase eq 1
						/ECAM/warning-phase eq 10
					</test>
					/systems/air-conditioning/valves/hot-air eq 0
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/trim-air-fault-input">
			<default value="0"/>
			<test logic="AND" value="1">
				<test logic="OR">
					/systems/failures/pneumatics/trim-valve-cabin-aft eq 1
					/systems/failures/pneumatics/trim-valve-cabin-fwd eq 1
					/systems/failures/pneumatics/trim-valve-cockpit eq 1
				</test>
				/ECAM/warnings/logic/trim-air-fault-inhibit eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/cabin-fans-fault">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/failures/pneumatics/cabin-fans eq 1
				/systems/electrical/bus/dc-1 ge 25
				/systems/electrical/bus/dc-2 ge 25
				/systems/electrical/bus/ac-1 ge 110
				/systems/electrical/bus/ac-2 ge 110
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/rud-trav-lim-sys-1-fault-cmd">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/navigation/adr/operating-1 eq 1
				/systems/navigation/adr/operating-3 eq 1
				/systems/electrical/bus/dc-ess-shed ge 25
				/systems/electrical/bus/ac-1 ge 110
				/systems/fctl/fac1-rtlu-avail eq 0
				/systems/fctl/fac1-healthy-signal eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/rud-trav-lim-sys-2-fault-cmd">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/navigation/adr/operating-2 eq 1
				/systems/navigation/adr/operating-3 eq 1
				/systems/electrical/bus/dc-2 ge 25
				/systems/electrical/bus/ac-2 ge 110
				/systems/fctl/fac2-rtlu-avail eq 0
				/systems/fctl/fac2-healthy-signal eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/rud-trav-lim-sys-fault">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/rud-trav-lim-sys-1-fault-cmd eq 1
				/ECAM/warnings/logic/rud-trav-lim-sys-2-fault-cmd eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/rud-trav-lim-sys-1-fault">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/rud-trav-lim-sys-1-fault-cmd eq 1
				/ECAM/warnings/logic/rud-trav-lim-sys-fault eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/rud-trav-lim-sys-2-fault">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/warnings/logic/rud-trav-lim-sys-2-fault-cmd eq 1
				/ECAM/warnings/logic/rud-trav-lim-sys-fault eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/fac-12-fault">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/electrical/bus/dc-ess-shed ge 25
				/systems/electrical/bus/dc-2 ge 25
				/systems/fctl/fac1-healthy-signal eq 0
				/systems/fctl/fac2-healthy-signal eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/fac-1-fault">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/navigation/adr/operating-1 eq 1
				/systems/navigation/adr/operating-3 eq 1
				/systems/electrical/bus/dc-ess-shed ge 25
				/systems/electrical/bus/ac-1 ge 110
				/systems/fctl/fac1-healthy-signal eq 0
				/systems/fctl/fac2-healthy-signal eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/fac-2-fault">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/navigation/adr/operating-2 eq 1
				/systems/navigation/adr/operating-3 eq 1
				/systems/electrical/bus/dc-2 ge 25
				/systems/electrical/bus/ac-2 ge 110
				/systems/fctl/fac1-healthy-signal eq 1
				/systems/fctl/fac2-healthy-signal eq 0
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/yaw-damper-1-fault-eng-start">
			<default value="0"/>
			<test logic="AND" value="1">
				/controls/engines/engine[1]/cutoff-switch eq 0 <!-- opposite side -->
				/systems/hydraulic/green-psi lt 1500
				/ECAM/timer/ground-calc eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/yaw-damper-1-fault-green">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/hydraulic/green-psi lt 1500
				/ECAM/warning-phase eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/yaw-damper-1-fault-adr">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/navigation/adr/operating-1 eq 0
				/systems/navigation/adr/operating-3 eq 0
				<test logic="OR">
					/ECAM/warning-phase eq 1
					/ECAM/warning-phase eq 10
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/yaw-damper-1-fault">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/navigation/adr/operating-1 eq 1
				/systems/navigation/adr/operating-3 eq 1
				/systems/electrical/bus/dc-ess-shed ge 25
				/systems/electrical/bus/ac-1 ge 110
				/ECAM/warnings/logic/yaw-damper-1-fault-eng-start eq 0
				/ECAM/warnings/logic/yaw-damper-1-fault-green eq 0
				/ECAM/warnings/logic/yaw-damper-1-fault-adr eq 0
				/ECAM/irs-in-align eq 0
				/systems/fctl/yawdamper-1-active eq 0
				/systems/fctl/fac1-healthy-signal eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/yaw-damper-2-fault-eng-start">
			<default value="0"/>
			<test logic="AND" value="1">
				/controls/engines/engine[0]/cutoff-switch eq 0 <!-- opposite side -->
				/systems/hydraulic/yellow-psi lt 1500
				/ECAM/timer/ground-calc eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/yaw-damper-2-fault-yellow">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/hydraulic/yellow-psi lt 1500
				/ECAM/warning-phase eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/yaw-damper-2-fault-adr">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/navigation/adr/operating-2 eq 0
				/systems/navigation/adr/operating-3 eq 0
				<test logic="OR">
					/ECAM/warning-phase eq 1
					/ECAM/warning-phase eq 10
				</test>
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/yaw-damper-2-fault">
			<default value="0"/>
			<test logic="AND" value="1">
				/systems/navigation/adr/operating-2 eq 1
				/systems/navigation/adr/operating-3 eq 1
				/systems/electrical/bus/dc-2 ge 25
				/systems/electrical/bus/ac-2 ge 110
				/ECAM/warnings/logic/yaw-damper-2-fault-eng-start eq 0
				/ECAM/warnings/logic/yaw-damper-2-fault-yellow eq 0
				/ECAM/warnings/logic/yaw-damper-2-fault-adr eq 0
				/ECAM/irs-in-align eq 0
				/systems/fctl/yawdamper-2-active eq 0
				/systems/fctl/fac2-healthy-signal eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/yaw-damper-12-fault">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/irs-in-align eq 0
				<test logic="OR">
					/systems/navigation/adr/operating-1 eq 1
					/systems/navigation/adr/operating-2 eq 1
					/systems/navigation/adr/operating-3 eq 1
				</test>
				<test logic="OR">
					/systems/electrical/bus/dc-ess-shed ge 25
					/systems/electrical/bus/ac-1 ge 110
					/systems/electrical/bus/dc-2 ge 25
					/systems/electrical/bus/ac-2 ge 110
				</test>
				/ECAM/warnings/logic/yaw-damper-1-fault-green eq 0
				/ECAM/warnings/logic/yaw-damper-2-fault-yellow eq 0
				/ECAM/warnings/logic/yaw-damper-1-fault eq 1
				/ECAM/warnings/logic/yaw-damper-2-fault eq 1
			</test>
		</switch>
		
		<switch name="/ECAM/warnings/logic/nav-gpws-terr-fault">
			<default value="0"/>
			<test logic="AND" value="1">
				/ECAM/irs-in-align eq 0
				/systems/navigation/adr/operating-1 eq 1
				/systems/electrical/bus/ac-1 ge 110
				/ECAM/warning-phase ne 1
				/ECAM/warning-phase ne 10
				/FMGC/FCU-working eq 1
				/instrumentation/mk-viii/inputs/discretes/ta-tcf-inhibit eq 1
			</test>
		</switch>
	</channel>

</system>