<?xml version="1.0"?> <!-- Copyright (c) 2019 Jonathan Redpath (legoboyvdlp) --> <system name="A320: Lights"> <channel name="Interior Lights"> <switch name="/controls/lighting/reading-light-tied"> <default value="0" /> <test value="/controls/lighting/main-flood-knb"> /systems/electrical/bus/dc-1 gt 25 </test> </switch> <switch name="/controls/lighting/panel-light-tied"> <default value="0" /> <test logic="OR" value="/controls/lighting/main-flood-knb"> /systems/electrical/bus/dc-ess gt 25 /systems/electrical/bus/dc-1 gt 25 </test> </switch> <switch name="/controls/lighting/pedestal-light-tied"> <default value="0" /> <test value="/controls/lighting/ped-flood-knb"> /systems/electrical/bus/dc-1 gt 25 </test> </switch> <switch name="/controls/lighting/fcu-panel-norm-tied"> <default value="0" /> <test value="/controls/lighting/fcu-panel-knb"> /systems/electrical/bus/ac-1 gt 25 </test> </switch> <switch name="/controls/lighting/main-panel-norm-tied"> <default value="0" /> <test value="/controls/lighting/main-panel-knb"> /systems/electrical/bus/ac-1 gt 25 </test> </switch> <switch name="/controls/lighting/overhead-panel-norm-tied"> <default value="0" /> <test value="/controls/lighting/overhead-panel-knb"> /systems/electrical/bus/ac-1 gt 25 </test> </switch> <switch name="/controls/lighting/annunciator-lights-tied"> <default value="0" /> <test logic="OR" value="1"> <!-- TODO: add static inverter as a source, also dc-2 switching --> /systems/electrical/bus/ac-1 gt 110 /systems/electrical/bus/ac-2 gt 110 /systems/electrical/bus/dc-2 gt 25 </test> </switch> </channel> <channel name="External lights"> <switch name="/controls/lighting/landing-lights[1]"> <default value="0"/> <test logic="AND" value="1"> /controls/switches/landing-lights-l eq 1 /systems/electrical/bus/ac-1 ge 110 /controls/lighting/landing-light-pos-l eq 1 </test> </switch> <switch name="/controls/lighting/landing-lights[2]"> <default value="0"/> <test logic="AND" value="1"> /controls/switches/landing-lights-r ne 0 /systems/electrical/bus/ac-2 ge 110 /controls/lighting/landing-light-pos-r eq 1 </test> </switch> <switch name="/controls/lighting/landing-light-pos-l-cmd"> <default value="0"/> <test logic="AND" value="1"> /controls/switches/landing-lights-l ne 0 </test> </switch> <switch name="/controls/lighting/landing-light-pos-r-cmd"> <default value="0"/> <test logic="AND" value="1"> /controls/switches/landing-lights-r ne 0 </test> </switch> <switch name="/controls/lighting/landing-light-pos-l-power"> <default value="0"/> <test logic="AND" value="0.2"> /systems/electrical/bus/ac-1 ge 110 </test> </switch> <switch name="/controls/lighting/landing-light-pos-r-power"> <default value="0"/> <test logic="AND" value="0.2"> /systems/electrical/bus/ac-2 ge 110 </test> </switch> <actuator name="/controls/lighting/landing-light-pos-l"> <input>/controls/lighting/landing-light-pos-l-cmd</input> <rate_limit>/controls/lighting/landing-light-pos-l-power</rate_limit> </actuator> <actuator name="/controls/lighting/landing-light-pos-r"> <input>/controls/lighting/landing-light-pos-r-cmd</input> <rate_limit>/controls/lighting/landing-light-pos-r-power</rate_limit> </actuator> </channel> </system>