/systems/oxygen/cockpit-oxygen/cockpit-bottle-L /systems/oxygen/cockpit-oxygen/distributor-manifold-L /controls/oxygen/cockpit-oxygen-supply-pb eq 1 /systems/electrical/bus/dc-ess-shed ge 25 /systems/oxygen/cockpit-oxygen/supply-valve-cmd 10 /systems/oxygen/cockpit-oxygen/distributor-manifold-L 15 /controls/oxygen/cockpit-mask-1-on /systems/pressurization/cabinalt/controls/oxygen/cockpit-mask-1-selector 0 1 0 0 29.5 5000 0.0 31.0 8000 0.17 36.4 10000 0.71 36.9 15000 5.60 37.9 20000 15.9 38.9 30000 30.4 39.9 35000 40.9 40.9 40000 41.9 41.9
/systems/oxygen/cockpit-oxygen/distributor-manifold-L 15 /controls/oxygen/cockpit-mask-2-on /systems/pressurization/cabinalt/controls/oxygen/cockpit-mask-2-selector 0 1 0 0 29.5 5000 0.0 31.0 8000 0.17 36.4 10000 0.71 36.9 15000 5.60 37.9 20000 15.9 38.9 30000 30.4 39.9 35000 40.9 40.9 40000 41.9 41.9
/systems/oxygen/cockpit-oxygen/distributor-manifold-L 15 /controls/oxygen/cockpit-mask-3-on /systems/pressurization/cabinalt/controls/oxygen/cockpit-mask-3-selector 0 1 0 0 29.5 5000 0.0 31.0 8000 0.17 36.4 10000 0.71 36.9 15000 5.60 37.9 20000 15.9 38.9 30000 30.4 39.9 35000 40.9 40.9 40000 41.9 41.9
/systems/oxygen/cockpit-oxygen/distributor-manifold-L 15 /controls/oxygen/cockpit-mask-4-on /systems/pressurization/cabinalt/controls/oxygen/cockpit-mask-4-selector 0 1 0 0 29.5 5000 0.0 31.0 8000 0.17 36.4 10000 0.71 36.9 15000 5.60 37.9 20000 15.9 38.9 30000 30.4 39.9 35000 40.9 40.9 40000 41.9 41.9
/systems/oxygen/cockpit-oxygen/cockpit-bottle-L -/systems/oxygen/cockpit-oxygen/hp-regulator-flow-rate 60 simulation/channel-dt /systems/oxygen/cockpit-oxygen/cockpit-bottle-L 0.0 2183.0 58.58145 /systems/oxygen/cockpit-oxygen/cockpit-bottle-L 0.4512568 /systems/oxygen/cockpit-oxygen/cockpit-bottle-L 0 0 500 200 1000 275 2000 300 2183 300
/systems/oxygen/cockpit-oxygen/supply-valve /systems/oxygen/cockpit-oxygen/distributor-manifold-L 0 300 14.5 170 15 0
/systems/oxygen/cockpit-oxygen/bottle-flow-rate /systems/oxygen/cockpit-oxygen/supply-valve /systems/oxygen/cockpit-oxygen/mask-1-flow-rate /systems/oxygen/cockpit-oxygen/mask-2-flow-rate /systems/oxygen/cockpit-oxygen/mask-3-flow-rate /systems/oxygen/cockpit-oxygen/mask-4-flow-rate /systems/oxygen/cockpit-oxygen/distributor-fill-rate 0.0 /systems/oxygen/cockpit-oxygen/hp-regulator-flow-rate-calc -/systems/oxygen/cockpit-oxygen/mask-1-flow-rate -/systems/oxygen/cockpit-oxygen/mask-2-flow-rate -/systems/oxygen/cockpit-oxygen/mask-3-flow-rate -/systems/oxygen/cockpit-oxygen/mask-4-flow-rate /systems/oxygen/cockpit-oxygen/hp-regulator-flow-rate /systems/oxygen/cockpit-oxygen/distributor-manifold-L /systems/oxygen/cockpit-oxygen/distributor-manifold-rate 60 simulation/channel-dt /systems/oxygen/cockpit-oxygen/distributor-manifold-L 0.0 15.0 75 /systems/oxygen/cockpit-oxygen/distributor-manifold-L 1 /systems/oxygen/cockpit-oxygen/distributor-psi lt 50
/systems/pressurization/cabinalt ge 14000 /systems/electrical/bus/dc-ess ge 25 /systems/oxygen/passenger-oxygen/pressure-switch eq 1 /controls/oxygen/passenger-mask-deploy-man eq 1 /systems/oxygen/passenger-oxygen/masks-deploy-cmd eq 1 /systems/electrical/bus/ac-ess-shed ge 110 /controls/oxygen/passenger-mask-reset eq 1 /systems/electrical/bus/dc-ess-shed lt 25 /systems/oxygen/passenger-oxygen/masks-deploy-cmd eq 1 /systems/electrical/bus/dc-ess-shed ge 25 /systems/oxygen/passenger-oxygen/sys-on-light