Timer for the ECAM system /ECAM/phases/timer/eng1idle 100 0.033 Timer for the ECAM system /ECAM/phases/timer/eng2idle 100 0.033 Timer for the ECAM system /ECAM/phases/timer/eng1or2 100 0.033 Timer for the ECAM system /ECAM/phases/timer/to-inhibit 100 0.33 Timer for the ECAM system /ECAM/phases/timer/ldg-inhibit 100 0.33 Timer for the ECAM system /ECAM/warnings/timer/bleed-1-fault 100 0.2 Timer for the ECAM system /ECAM/warnings/timer/bleed-2-fault 100 0.2 Timer for the ECAM system /ECAM/warnings/logic/apu-bleed-fault 100 0.1 Timer for the ECAM system /systems/pneumatics/warnings/crossbleed-disag 100 0.1 /systems/electrical/bus/dc-2 ge 25 /systems/electrical/relay/dc-ess-feed-bat/contact-pos eq 1 /systems/apu/available eq 1 /controls/apu/master eq 1 /controls/pneumatics/switches/apu eq 0 /systems/pneumatics/valves/apu-bleed-valve ne 0 /systems/apu/available eq 1 /controls/apu/master eq 1 /controls/pneumatics/switches/apu eq 1 /systems/pneumatics/valves/apu-bleed-valve ne 1 /ECAM/warnings/timer/xbleed-fault-output eq 1 /ECAM/warnings/timer/xbleed-fault-output-10 eq 1 /ECAM/warnings/timer/xbleed-fault-output-15 eq 0 /systems/apu/available eq 1 /controls/pneumatics/switches/apu eq 1 /systems/pneumatics/valves/engine-1-prv-valve eq 0 /systems/pneumatics/valves/engine-2-prv-valve eq 0 /systems/pneumatics/warnings/crossbleed-disag-open eq 1