/systems/electrical/some-electric-thingie/rat-deploy /systems/electrical/sources/bat-1/percent/systems/failures/electrical/bat-1 0 1 0 0.0 0.0 10 24.0 4.0 50 25.5 5.0 100 31.0 7.0
/systems/electrical/sources/bat-1/limiter eq 1 /controls/electrical/switches/bat-1 eq 1 /systems/electrical/sources/bat-1/volt ge 10 /systems/electrical/sources/bat-2/percent/systems/failures/electrical/bat-2 0 1 0 0.0 0.0 10 24.0 4.0 50 25.5 5.0 100 31.0 7.0
/systems/electrical/sources/bat-2/limiter eq 1 /controls/electrical/switches/bat-2 eq 1 /systems/electrical/sources/bat-2/volt ge 10 /engines/engine[0]/n2-actual 90.298 /controls/engines/engine[0]/fire-btn eq 1 /systems/failures/electrical/idg-1 eq 1 /controls/electrical/switches/idg-1-disc eq 0 /systems/electrical/sources/idg-1/drive-rpm-input /systems/electrical/sources/idg-1/working 12000 /systems/electrical/sources/idg-1/drive-rpm 1.3 2.8 /systems/electrical/sources/idg-1/csd-gearbox-ratio-cmd 40 /systems/electrical/sources/idg-1/drive-rpm /systems/electrical/sources/idg-1/csd-gearbox-ratio /systems/electrical/sources/idg-1/csd-rpm 115 12000 /systems/electrical/sources/idg-1/csd-rpm 4 120 /systems/failures/electrical/gen-1 ne 1 /systems/electrical/sources/idg-1/csd-rpm ge 11500 /systems/electrical/sources/idg-1/pmg-volt /systems/electrical/sources/idg-1/gcr-relay /systems/electrical/sources/idg-1/pmg-hertz /systems/electrical/sources/idg-1/gcr-relay /engines/engine[1]/n2-actual 90.298 /controls/engines/engine[1]/fire-btn eq 1 /systems/failures/electrical/idg-2 eq 1 /controls/electrical/switches/idg-2-disc eq 0 /systems/electrical/sources/idg-2/drive-rpm-input /systems/electrical/sources/idg-2/working 12000 /systems/electrical/sources/idg-2/drive-rpm 1.3 2.8 /systems/electrical/sources/idg-2/csd-gearbox-ratio-cmd 40 /systems/electrical/sources/idg-2/drive-rpm /systems/electrical/sources/idg-2/csd-gearbox-ratio /systems/electrical/sources/idg-2/csd-rpm 115 12000 /systems/electrical/sources/idg-2/csd-rpm 4 120 /systems/failures/electrical/gen-2 ne 1 /systems/electrical/sources/idg-2/csd-rpm ge 11500 /systems/electrical/sources/idg-2/pmg-volt /systems/electrical/sources/idg-2/gcr-relay /systems/electrical/sources/idg-2/pmg-hertz /systems/electrical/sources/idg-2/gcr-relay /engines/engine[2]/n1 240.34 /controls/apu/fire-btn eq 1 /systems/electrical/sources/apu/drive-rpm-input /systems/electrical/sources/apu/working /systems/electrical/sources/apu/drive-rpm-input 115 24000 /systems/electrical/sources/apu/drive-rpm-input 2 120 /controls/electrical/switches/apu eq 1 /systems/failures/electrical/apu ne 1 /systems/electrical/sources/apu/drive-rpm-input ge 23000 /systems/electrical/sources/apu/pmg-volt /systems/electrical/sources/apu/gcr-relay /systems/electrical/sources/apu/pmg-hertz /systems/electrical/sources/apu/gcr-relay /controls/electrical/ground-cart 1 115 0 /systems/electrical/sources/ext/output-volt 110 400 0 /systems/failures/electrical/stat-inv eq 1 /systems/electrical/some-electric-thingie/emer-gen-operate eq 1 /systems/electrical/sources/emer-gen/coupled ne 1 /instrumentation/airspeed-indicator/indicated-speed-kt lt 100 /instrumentation/airspeed-indicator/indicated-speed-kt ge 50 /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /sim/time/elapsed-sec gt 10 /instrumentation/airspeed-indicator/indicated-speed-kt lt 50 /controls/electrical/switches/bat-1 eq 1 /controls/electrical/switches/bat-2 eq 1 /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /sim/time/elapsed-sec gt 10 /systems/electrical/sources/si-1/inverter-active 1 115 /systems/electrical/sources/bat-1/volt 0 /systems/electrical/sources/bat-1/volt /systems/electrical/sources/si-1/inverter-gain /systems/electrical/sources/si-1/output-volt ge 110 /instrumentation/airspeed-indicator/indicated-speed-kt gt 100 /sim/time/elapsed-sec gt 30 /systems/electrical/bus/ac-1 eq 0 /systems/electrical/bus/ac-2 eq 0 /controls/electrical/switches/emer-elec-man-on eq 0 /controls/hydraulic/switches/rat-man eq 1 /controls/electrical/switches/emer-elec-man-on eq 1 /controls/electrical/switches/emer-gen-test eq 1 /systems/electrical/bus/ac-1 ne 0 /systems/electrical/bus/ac-2 ne 0 /instrumentation/airspeed-indicator/indicated-speed-kt gt 100 /systems/electrical/bus/ac-1 eq 0 /systems/electrical/bus/ac-2 eq 0 gear/unit[0]/WOW eq 0 /controls/electrical/switches/emer-elec-man-on eq 0 gear/unit[0]/WOW eq 0 /controls/electrical/switches/emer-elec-man-on eq 1 /systems/electrical/some-electric-thingie/emer-gen-operate eq 1 /systems/hydraulic/sources/rat/position eq 1 /controls/electrical/switches/emer-gen-test eq 1 /systems/electrical/bus/ac-1 ne 0 /systems/electrical/bus/ac-2 ne 0 /systems/electrical/some-electric-thingie/emer-gen-operating-on-rat 0.0 1.0 /systems/electrical/sources/emer-gen/coupled-kin eq 1 /systems/failures/electrical/emer-gen ne 1 /controls/electrical/switches/emer-gen-test eq 1 /systems/failures/electrical/emer-gen ne 1 /systems/electrical/bus/ac-1 ne 0 /systems/electrical/bus/ac-2 ne 0 /systems/electrical/some-electric-thingie/emer-gen-operate eq 1 /systems/electrical/sources/emer-gen/coupled eq 1 /systems/hydraulic/blue-psi ge 2500 /systems/failures/electrical/emer-gen eq 0 /systems/electrical/sources/emer-gen/output-volt ge 110 /controls/electrical/switches/gen-1 eq 1 /systems/electrical/sources/idg-1/output-volt ge 110 /systems/electrical/sources/idg-1/output-volt le 130 /systems/electrical/sources/idg-1/output-hertz ge 390 /systems/electrical/sources/idg-1/output-hertz le 410 /controls/electrical/switches/gen-1-line-contactor ne 1 /systems/electrical/relay/gen-1-glc/contact-pos eq 1 /controls/electrical/switches/gen-2 eq 1 /systems/electrical/sources/idg-2/output-volt ge 110 /systems/electrical/sources/idg-2/output-volt lt 130 /systems/electrical/sources/idg-2/output-hertz ge 390 /systems/electrical/sources/idg-2/output-hertz le 410 /systems/electrical/relay/gen-2-glc/contact-pos eq 1 /systems/electrical/sources/ext/output-volt ge 110 /controls/electrical/switches/ext-pwr eq 1 /controls/electrical/ground-cart eq 1 /systems/electrical/relay/ext-epc/contact-pos eq 1 /controls/apu/master eq 1 /controls/electrical/switches/apu eq 1 /systems/electrical/sources/apu/output-volt ge 110 /systems/electrical/sources/apu/output-volt lt 130 /systems/electrical/sources/apu/output-hertz ge 390 /systems/electrical/sources/apu/output-hertz le 410 /systems/electrical/relay/ext-epc/contact-pos eq 0 /systems/electrical/relay/apu-glc/contact-pos eq 1 /systems/electrical/sources/emer-gen/output-volt ge 110 /systems/failures/electrical/emer-gen ne 1 /systems/electrical/relay/ac-ess-feed-1/output lt 110 /systems/electrical/relay/ac-ess-feed-2/output lt 110 /systems/electrical/relay/emer-glc/contact-pos eq 1 /controls/electrical/switches/bus-tie eq 0 /systems/electrical/relay/gen-1-glc/contact-pos eq 1 /systems/electrical/relay/gen-2-glc/contact-pos eq 0 /systems/electrical/relay/apu-glc/contact-pos eq 0 /systems/electrical/relay/ext-epc/contact-pos eq 0 /controls/electrical/switches/bus-tie eq 1 /systems/electrical/relay/gen-1-glc/contact-pos eq 0 /systems/electrical/bus/ac-bus-tie ge 110 /controls/electrical/switches/bus-tie eq 1 /systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1 /controls/electrical/switches/bus-tie eq 0 /systems/electrical/relay/gen-2-glc/contact-pos eq 1 /systems/electrical/relay/gen-1-glc/contact-pos eq 0 /systems/electrical/relay/apu-glc/contact-pos eq 0 /systems/electrical/relay/ext-epc/contact-pos eq 0 /controls/electrical/switches/bus-tie eq 1 /systems/electrical/relay/gen-2-glc/contact-pos eq 0 /systems/electrical/bus/ac-bus-tie ge 110 /controls/electrical/switches/bus-tie eq 1 /systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1 /controls/electrical/switches/ac-ess-feed eq 0 /controls/electrical/switches/emer-gen-test eq 0 /systems/electrical/relay/ac-ess-feed-1/contact-pos eq 1 /controls/electrical/switches/ac-ess-feed eq 1 /controls/electrical/switches/emer-gen-test eq 0 /systems/electrical/relay/ac-ess-feed-2/contact-pos eq 1 /systems/electrical/bus/ac-1 eq 0 /systems/electrical/bus/ac-2 eq 0 /systems/electrical/relay/emer-glc/output ge 110 /systems/electrical/bus/ac-1 ne 0 /systems/electrical/bus/ac-2 ne 0 /controls/electrical/switches/emer-gen-test eq 1 /systems/electrical/relay/emer-glc/output ge 110 /systems/electrical/relay/ac-ess-feed-emer-gen/contact-pos eq 1 /instrumentation/airspeed-indicator/indicated-speed-kt ge 50 /systems/electrical/bus/ac-1 eq 0 /systems/electrical/bus/ac-2 eq 0 /controls/electrical/switches/emer-gen-test eq 0 /systems/electrical/relay/emer-glc/output lt 110 /systems/electrical/relay/ac-ess-feed-inverter/contact-pos eq 1 /systems/electrical/sources/si-1/inverter-active eq 1 /controls/electrical/switches/emer-gen-test eq 1 /systems/electrical/relay/ac-ess-shed-switch/contact-pos eq 1 /controls/electrical/switches/galley eq 1 /systems/electrical/relay/gen-1-glc/output ne 0 /systems/electrical/relay/gen-2-glc/output ne 0 /systems/electrical/relay/galley-bus-1-shed-switch/contact-pos eq 1 /controls/electrical/switches/galley eq 1 /systems/electrical/relay/gen-1-glc/output ne 0 /systems/electrical/relay/gen-2-glc/output ne 0 /systems/electrical/relay/galley-bus-2-shed-switch/contact-pos eq 1 Tell which source is being used for priority purpose /systems/electrical/relay/gen-1-glc/contact-pos eq 1 /systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1 /systems/failures/electrical/ac-1-bus 1 0 /systems/electrical/relay/gen-1-glc/output /systems/electrical/relay/ac-bus-ac-bus-tie-1/output Tell which source is being used for priority purpose /systems/electrical/relay/gen-2-glc/contact-pos eq 1 /systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1 /systems/failures/electrical/ac-2-bus 1 0 /systems/electrical/relay/gen-2-glc/output /systems/electrical/relay/ac-bus-ac-bus-tie-2/output /systems/electrical/bus/ac-1 0.2260869565 /systems/electrical/bus/ac-2 0.2260869565 /systems/electrical/bus/ac-ess 0.2260869565 /systems/electrical/sources/si-1/output-volt 1 /systems/failures/electrical/ac-ess-bus 1 0 /systems/electrical/relay/ac-ess-feed-1/output /systems/electrical/relay/ac-ess-feed-2/output /systems/electrical/relay/ac-ess-feed-emer-gen/output /systems/electrical/relay/ac-ess-feed-inverter/output /systems/electrical/relay/ac-ess-shed-switch/output /systems/electrical/relay/ac-ess-shed-switch/contact-pos /systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1 /systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1 /systems/electrical/relay/ext-epc/contact-pos eq 1 /systems/electrical/relay/apu-glc/contact-pos eq 1 /systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1 /systems/electrical/bus/ac-1-src ne 2 /systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1 /systems/electrical/bus/ac-2-src ne 2 /systems/electrical/bus/ac-1 0.24347826086956523 /systems/electrical/sources/tr-1/output-volt 0 0 27.5 200
/systems/electrical/bus/ac-2 0.24347826086956523 /systems/electrical/sources/tr-2/output-volt 0 0 27.5 200
/systems/failures/electrical/ess-tr eq 0 /systems/electrical/bus/ac-ess /systems/electrical/sources/ess-tr/working /systems/electrical/sources/ess-tr/output-volt 0 0 27.5 200
/systems/electrical/sources/tr-1/output-volt ne 0 /systems/electrical/sources/tr-1/output-amp ne 0 /systems/failures/electrical/tr-1 eq 0 /systems/electrical/relay/tr-contactor-1/contact-pos eq 1 /systems/electrical/relay/tr-contactor-1/contact-pos eq 1 /systems/electrical/sources/tr-2/output-volt ne 0 /systems/electrical/sources/tr-2/output-amp ne 0 /systems/failures/electrical/tr-2 eq 0 /systems/electrical/relay/tr-contactor-2/contact-pos eq 1 /systems/electrical/relay/tr-contactor-2/contact-pos eq 1 /systems/electrical/bus/ac-1 ge 110 /systems/electrical/bus/dc-1 ge 25 /systems/electrical/relay/tr-contactor-1/contact-pos eq 1 /systems/electrical/bus/dc-bat ge 25 /systems/electrical/bus/dc-bat-src ne 3 /systems/electrical/relay/tr-contactor-1/contact-pos eq 0 /systems/electrical/relay/tr-contactor-2/contact-pos eq 0 /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1 /systems/electrical/relay/dc-ess-feed-bat/contact-pos eq 0 /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 0 /systems/electrical/relay/tr-contactor-2/contact-pos eq 1 /systems/electrical/bus/dc-2 ge 25 /systems/electrical/bus/dc-bat ge 25 /systems/electrical/bus/dc-bat-src ne 3 /systems/electrical/relay/tr-contactor-1/contact-pos eq 0 /systems/electrical/relay/tr-contactor-2/contact-pos eq 0 /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1 /systems/electrical/relay/tr-contactor-1/output lt 25 /systems/electrical/relay/tr-contactor-2/output lt 25 /systems/electrical/relay/emer-glc/output ge 110 /systems/electrical/sources/ess-tr/output-volt ge 25 /systems/electrical/relay/dc-ess-feed-tr/contact-pos eq 1 /systems/electrical/relay/dc-ess-feed-tr/contact-pos eq 1 /systems/electrical/relay/dc-ess-feed-tr/contact-pos eq 0 /systems/electrical/relay/tr-contactor-1/contact-pos eq 1 /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1 /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 0 /controls/electrical/switches/emer-gen-test eq 0 /systems/electrical/bus/dc-1 ge 25 /systems/electrical/relay/dc-ess-feed-bat/contact-pos eq 1 /systems/electrical/sources/si-1/inverter-active eq 1 /controls/electrical/switches/emer-gen-test eq 1 /systems/electrical/relay/dc-ess-shed-switch/contact-pos eq 1 /systems/electrical/relay/dc-svc-bus-contactor-tr/contact-pos eq 1 /systems/electrical/relay/dc-svc-bus-contactor-bus-2/contact-pos eq 1 Tell which source is being used for priority purpose /systems/electrical/relay/tr-contactor-1/output ge 25 /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1 /systems/failures/electrical/dc-1-bus 1 0 /systems/electrical/relay/tr-contactor-1/output /systems/electrical/relay/dc-bus-tie-dc-1/output Tell which source is being used for priority purpose /systems/electrical/relay/tr-contactor-2/output ge 25 /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1 /systems/failures/electrical/dc-2-bus 1 0 /systems/electrical/relay/tr-contactor-2/output /systems/electrical/relay/dc-bus-tie-dc-2/output /systems/electrical/relay/dc-svc-bus-contactor-tr/output /systems/electrical/relay/dc-svc-bus-contactor-bus-2/output /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1 /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1 Tell which source is being used for priority purpose /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1 /systems/electrical/bus/dc-1-src ne 2 /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1 /systems/electrical/bus/dc-2-src ne 2 /instrumentation/airspeed-indicator/indicated-speed-kt lt 50 /controls/electrical/switches/bat-1 eq 1 /controls/electrical/switches/bat-2 eq 1 /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /controls/electrical/switches/bat-1 eq 1 /controls/electrical/switches/bat-2 eq 1 /systems/apu/dc-bat-three-minutes eq 1 /systems/failures/electrical/dc-bat-bus eq 1 /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1 /systems/electrical/bus/dc-1-src ne 2 /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1 /systems/electrical/bus/dc-2-src ne 2 /instrumentation/airspeed-indicator/indicated-speed-kt lt 50 /controls/electrical/switches/bat-1 eq 1 /systems/electrical/bus/dc-bat-src eq 3 /systems/electrical/sources/bat-1/volt ge 25 /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /systems/apu/dc-bat-three-minutes eq 1 /controls/electrical/switches/bat-1 eq 1 /systems/electrical/bus/dc-bat-src eq 3 /systems/electrical/sources/bat-1/volt ge 25 /instrumentation/airspeed-indicator/indicated-speed-kt lt 50 /controls/electrical/switches/bat-2 eq 1 /systems/electrical/bus/dc-bat-src eq 3 /systems/electrical/sources/bat-2/volt ge 25 /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /systems/apu/dc-bat-three-minutes eq 1 /controls/electrical/switches/bat-2 eq 1 /systems/electrical/bus/dc-bat-src eq 3 /systems/electrical/sources/bat-2/volt ge 25 /systems/failures/electrical/dc-ess-bus 1 0 /systems/electrical/relay/dc-ess-feed-bat/output /systems/electrical/relay/dc-ess-feed-tr/output /systems/electrical/bus/dc-ess 1 /systems/electrical/sources/bat-1/volt 1.0 /systems/electrical/sources/bat-2/volt 1.0 /systems/electrical/bus/ac-1 lt 110 /systems/electrical/bus/ac-2 lt 110 /systems/electrical/relay/ext-epc/contact-pos eq 0 /controls/electrical/switches/gen-1 eq 0 /systems/failures/electrical/gen-1 eq 1 /controls/electrical/switches/gen-2 eq 0 /systems/failures/electrical/gen-2 eq 1 /controls/electrical/switches/apu eq 0 /systems/failures/electrical/apu eq 1 /engines/engine[2]/n1 lt 94.9 /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /systems/electrical/some-electric-thingie/generator-1-pb eq 1 /controls/electrical/switches/bus-tie eq 0 /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /systems/electrical/some-electric-thingie/generator-2-pb eq 1 /controls/electrical/switches/bus-tie eq 0 /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /systems/electrical/some-electric-thingie/generator-1-pb eq 1 /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /systems/electrical/some-electric-thingie/generator-2-pb eq 1 Timer for the ECAM system /systems/electrical/relay/ac-ess-feed-inverter/contact-pos 100 0.1 This makes the FG stuff work because we killed the generic electrical /systems/electrical/bus/dc-1 ge 25 /systems/electrical/bus/dc-2 ge 25 /systems/electrical/outputs/efis /systems/electrical/outputs/fcp-power /systems/electrical/outputs/fuel-pump[0] /systems/electrical/outputs/fuel-pump[1] /systems/electrical/outputs/fuel-pump[2] /systems/electrical/outputs/gps /systems/electrical/outputs/mk-viii /systems/electrical/outputs/tacan /systems/electrical/outputs/turn-coordinator
/systems/electrical/bus/ac-ess lt 110 /controls/electrical/switches/apu eq 1 /systems/electrical/relay/apu-glc/contact-pos eq 0 /systems/electrical/relay/ext-epc/contact-pos eq 0 /systems/electrical/relay/gen-1-glc/contact-pos eq 0 /systems/electrical/relay/gen-2-glc/contact-pos eq 0 /systems/electrical/sources/apu/drive-rpm gt 2000 /systems/failures/electrical/bat-1 eq 1 /systems/failures/electrical/bat-2 eq 1 /controls/electrical/switches/gen-1 eq 1 /systems/electrical/relay/gen-1-glc/contact-pos eq 0 /controls/electrical/switches/gen-2 eq 1 /systems/electrical/relay/gen-2-glc/contact-pos eq 0 /systems/failures/electrical/idg-1 eq 1 /systems/electrical/sources/idg-1/csd-rpm gt 2000 /controls/electrical/switches/idg-1-disc-momentary eq 1 /systems/failures/electrical/idg-2 eq 1 /systems/electrical/sources/idg-2/csd-rpm gt 2000 /controls/electrical/switches/idg-2-disc-momentary eq 1 /systems/electrical/relay/dc-ess-feed-tr/output eq 0 /systems/electrical/bus/ac-1 eq 0 /systems/electrical/bus/ac-2 eq 0 position/wow eq 0