/systems/electrical/sources/bat-1/percent
/systems/failures/electrical/bat-1
0 1
0 0.0 0.0
10 24.0 4.0
50 25.5 5.0
100 31.0 7.0
/systems/electrical/sources/bat-1/limiter eq 1
/controls/electrical/switches/bat-1 eq 1
/systems/electrical/sources/bat-1/volt ge 10
/systems/electrical/sources/bat-2/percent
/systems/failures/electrical/bat-2
0 1
0 0.0 0.0
10 24.0 4.0
50 25.5 5.0
100 31.0 7.0
/systems/electrical/sources/bat-2/limiter eq 1
/controls/electrical/switches/bat-2 eq 1
/systems/electrical/sources/bat-2/volt ge 10
/engines/engine[0]/n2-actual
90.298
/controls/engines/engine[0]/fire-btn eq 1
/systems/failures/electrical/idg-1 eq 1
/controls/electrical/switches/idg-1-disc eq 0
/systems/electrical/sources/idg-1/drive-rpm-input
/systems/electrical/sources/idg-1/working
12000
/systems/electrical/sources/idg-1/drive-rpm
1.3
2.8
/systems/electrical/sources/idg-1/csd-gearbox-ratio-cmd
40
/systems/electrical/sources/idg-1/drive-rpm
/systems/electrical/sources/idg-1/csd-gearbox-ratio
/systems/electrical/sources/idg-1/csd-rpm
115
12000
/systems/electrical/sources/idg-1/csd-rpm
4
120
/systems/failures/electrical/gen-1 ne 1
/systems/electrical/sources/idg-1/csd-rpm ge 11500
/systems/electrical/sources/idg-1/pmg-volt
/systems/electrical/sources/idg-1/gcr-relay
/systems/electrical/sources/idg-1/pmg-hertz
/systems/electrical/sources/idg-1/gcr-relay
/engines/engine[1]/n2-actual
90.298
/controls/engines/engine[1]/fire-btn eq 1
/systems/failures/electrical/idg-2 eq 1
/controls/electrical/switches/idg-2-disc eq 0
/systems/electrical/sources/idg-2/drive-rpm-input
/systems/electrical/sources/idg-2/working
12000
/systems/electrical/sources/idg-2/drive-rpm
1.3
2.8
/systems/electrical/sources/idg-2/csd-gearbox-ratio-cmd
40
/systems/electrical/sources/idg-2/drive-rpm
/systems/electrical/sources/idg-2/csd-gearbox-ratio
/systems/electrical/sources/idg-2/csd-rpm
115
12000
/systems/electrical/sources/idg-2/csd-rpm
4
120
/systems/failures/electrical/gen-2 ne 1
/systems/electrical/sources/idg-2/csd-rpm ge 11500
/systems/electrical/sources/idg-2/pmg-volt
/systems/electrical/sources/idg-2/gcr-relay
/systems/electrical/sources/idg-2/pmg-hertz
/systems/electrical/sources/idg-2/gcr-relay
/systems/apu/rpm
240
/controls/APU/fire-btn eq 1
/systems/electrical/sources/apu/drive-rpm-input
/systems/electrical/sources/apu/working
/systems/electrical/sources/apu/drive-rpm-input
115
24000
/systems/electrical/sources/apu/drive-rpm-input
2
120
/controls/electrical/switches/apu eq 1
/systems/failures/electrical/apu ne 1
/systems/electrical/sources/apu/drive-rpm-input ge 23000
/systems/electrical/sources/apu/pmg-volt
/systems/electrical/sources/apu/gcr-relay
/systems/electrical/sources/apu/pmg-hertz
/systems/electrical/sources/apu/gcr-relay
/controls/electrical/ground-cart
1
115
0
/systems/electrical/sources/ext/output-volt
110
400
0
/systems/failures/electrical/stat-inv eq 1
/systems/electrical/some-electric-thingie/emer-gen-operate eq 1
/systems/electrical/sources/emer-gen/coupled ne 1
/instrumentation/airspeed-indicator/indicated-speed-kt lt 100
/instrumentation/airspeed-indicator/indicated-speed-kt ge 50
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
/sim/time/elapsed-sec gt 10
/instrumentation/airspeed-indicator/indicated-speed-kt lt 50
/controls/electrical/switches/bat-1 eq 1
/controls/electrical/switches/bat-2 eq 1
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
/sim/time/elapsed-sec gt 10
/systems/electrical/sources/si-1/inverter-active
1
115
/systems/electrical/sources/bat-1/volt
0
/systems/electrical/sources/bat-1/volt
/systems/electrical/sources/si-1/inverter-gain
/systems/electrical/sources/si-1/output-volt ge 110
/instrumentation/airspeed-indicator/indicated-speed-kt gt 100
/systems/electrical/bus/ac-1 eq 0
/systems/electrical/bus/ac-2 eq 0
/controls/electrical/switches/emer-elec-man-on eq 0
/controls/hydraulic/switches/rat-man eq 1
/controls/electrical/switches/emer-elec-man-on eq 1
/controls/electrical/switches/emer-gen-test eq 1
/systems/electrical/bus/ac-1 ne 0
/systems/electrical/bus/ac-2 ne 0
/instrumentation/airspeed-indicator/indicated-speed-kt gt 100
/systems/electrical/bus/ac-1 eq 0
/systems/electrical/bus/ac-2 eq 0
gear/unit[0]/WOW eq 0
/controls/electrical/switches/emer-elec-man-on eq 0
gear/unit[0]/WOW eq 0
/controls/electrical/switches/emer-elec-man-on eq 1
/systems/electrical/some-electric-thingie/emer-gen-operate eq 1
/systems/hydraulic/sources/rat/position eq 1
/controls/electrical/switches/emer-gen-test eq 1
/systems/electrical/bus/ac-1 ne 0
/systems/electrical/bus/ac-2 ne 0
/systems/electrical/some-electric-thingie/emer-gen-operating-on-rat
0.0
1.0
/systems/electrical/sources/emer-gen/coupled-kin eq 1
/systems/failures/electrical/emer-gen ne 1
/controls/electrical/switches/emer-gen-test eq 1
/systems/failures/electrical/emer-gen ne 1
/systems/electrical/bus/ac-1 ne 0
/systems/electrical/bus/ac-2 ne 0
/systems/electrical/some-electric-thingie/emer-gen-operate eq 1
/systems/electrical/sources/emer-gen/coupled eq 1
/systems/hydraulic/blue-psi ge 2500
/systems/failures/electrical/emer-gen eq 0
/systems/electrical/sources/emer-gen/output-volt ge 110
/controls/electrical/switches/gen-1 eq 1
/systems/electrical/sources/idg-1/output-volt ge 110
/systems/electrical/sources/idg-1/output-volt le 130
/systems/electrical/sources/idg-1/output-hertz ge 390
/systems/electrical/sources/idg-1/output-hertz le 410
/controls/electrical/switches/gen-1-line-contactor ne 1
/systems/electrical/relay/gen-1-glc/contact-pos eq 1
/controls/electrical/switches/gen-2 eq 1
/systems/electrical/sources/idg-2/output-volt ge 110
/systems/electrical/sources/idg-2/output-volt lt 130
/systems/electrical/sources/idg-2/output-hertz ge 390
/systems/electrical/sources/idg-2/output-hertz le 410
/systems/electrical/relay/gen-2-glc/contact-pos eq 1
/systems/electrical/sources/ext/output-volt ge 110
/controls/electrical/switches/ext-pwr eq 1
/controls/electrical/ground-cart eq 1
/systems/electrical/relay/ext-epc/contact-pos eq 1
/controls/APU/master eq 1
/controls/electrical/switches/apu eq 1
/systems/electrical/sources/apu/output-volt ge 110
/systems/electrical/sources/apu/output-volt lt 130
/systems/electrical/sources/apu/output-hertz ge 390
/systems/electrical/sources/apu/output-hertz le 410
/systems/electrical/relay/ext-epc/contact-pos eq 0
/systems/electrical/relay/apu-glc/contact-pos eq 1
/systems/electrical/sources/emer-gen/output-volt ge 110
/systems/failures/electrical/emer-gen ne 1
/systems/electrical/relay/ac-ess-feed-1/output lt 110
/systems/electrical/relay/ac-ess-feed-2/output lt 110
/systems/electrical/relay/emer-glc/contact-pos eq 1
/controls/electrical/switches/bus-tie eq 0
/systems/electrical/relay/gen-1-glc/contact-pos eq 1
/systems/electrical/relay/gen-2-glc/contact-pos eq 0
/systems/electrical/relay/apu-glc/contact-pos eq 0
/systems/electrical/relay/ext-epc/contact-pos eq 0
/controls/electrical/switches/bus-tie eq 1
/systems/electrical/relay/gen-1-glc/contact-pos eq 0
/systems/electrical/bus/ac-bus-tie ge 110
/controls/electrical/switches/bus-tie eq 1
/systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1
/controls/electrical/switches/bus-tie eq 0
/systems/electrical/relay/gen-2-glc/contact-pos eq 1
/systems/electrical/relay/gen-1-glc/contact-pos eq 0
/systems/electrical/relay/apu-glc/contact-pos eq 0
/systems/electrical/relay/ext-epc/contact-pos eq 0
/controls/electrical/switches/bus-tie eq 1
/systems/electrical/relay/gen-2-glc/contact-pos eq 0
/systems/electrical/bus/ac-bus-tie ge 110
/controls/electrical/switches/bus-tie eq 1
/systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1
/controls/electrical/switches/ac-ess-feed eq 0
/controls/electrical/switches/emer-gen-test eq 0
/systems/electrical/relay/ac-ess-feed-1/contact-pos eq 1
/controls/electrical/switches/ac-ess-feed eq 1
/controls/electrical/switches/emer-gen-test eq 0
/systems/electrical/relay/ac-ess-feed-2/contact-pos eq 1
/systems/electrical/bus/ac-1 eq 0
/systems/electrical/bus/ac-2 eq 0
/systems/electrical/relay/emer-glc/output ge 110
/systems/electrical/bus/ac-1 ne 0
/systems/electrical/bus/ac-2 ne 0
/controls/electrical/switches/emer-gen-test eq 1
/systems/electrical/relay/emer-glc/output ge 110
/systems/electrical/relay/ac-ess-feed-emer-gen/contact-pos eq 1
/instrumentation/airspeed-indicator/indicated-speed-kt ge 50
/systems/electrical/bus/ac-1 eq 0
/systems/electrical/bus/ac-2 eq 0
/controls/electrical/switches/emer-gen-test eq 0
/systems/electrical/relay/emer-glc/output lt 110
/systems/electrical/relay/ac-ess-feed-inverter/contact-pos eq 1
/systems/electrical/sources/si-1/inverter-active eq 1
/controls/electrical/switches/emer-gen-test eq 1
/systems/electrical/relay/ac-ess-shed-switch/contact-pos eq 1
/controls/electrical/switches/galley eq 1
/systems/electrical/relay/gen-1-glc/output ne 0
/systems/electrical/relay/gen-2-glc/output ne 0
/systems/electrical/relay/galley-bus-1-shed-switch/contact-pos eq 1
/controls/electrical/switches/galley eq 1
/systems/electrical/relay/gen-1-glc/output ne 0
/systems/electrical/relay/gen-2-glc/output ne 0
/systems/electrical/relay/galley-bus-2-shed-switch/contact-pos eq 1
Tell which source is being used for priority purpose
/systems/electrical/relay/gen-1-glc/contact-pos eq 1
/systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1
/systems/failures/electrical/ac-1-bus
1
0
/systems/electrical/relay/gen-1-glc/output
/systems/electrical/relay/ac-bus-ac-bus-tie-1/output
Tell which source is being used for priority purpose
/systems/electrical/relay/gen-2-glc/contact-pos eq 1
/systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1
/systems/failures/electrical/ac-2-bus
1
0
/systems/electrical/relay/gen-2-glc/output
/systems/electrical/relay/ac-bus-ac-bus-tie-2/output
/systems/electrical/bus/ac-1
0.2260869565
/systems/electrical/bus/ac-2
0.2260869565
/systems/electrical/bus/ac-ess
0.2260869565
/systems/electrical/sources/si-1/output-volt
1
/systems/failures/electrical/ac-ess-bus
1
0
/systems/electrical/relay/ac-ess-feed-1/output
/systems/electrical/relay/ac-ess-feed-2/output
/systems/electrical/relay/ac-ess-feed-emer-gen/output
/systems/electrical/relay/ac-ess-feed-inverter/output
/systems/electrical/relay/ac-ess-shed-switch/output
/systems/electrical/relay/ac-ess-shed-switch/contact-pos
/systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1
/systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1
/systems/electrical/relay/ext-epc/contact-pos eq 1
/systems/electrical/relay/apu-glc/contact-pos eq 1
/systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1
/systems/electrical/bus/ac-1-src ne 2
/systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1
/systems/electrical/bus/ac-2-src ne 2
/systems/electrical/bus/ac-1
0.24347826086956523
/systems/electrical/sources/tr-1/output-volt
0 0
27.5 200
/systems/electrical/bus/ac-2
0.24347826086956523
/systems/electrical/sources/tr-2/output-volt
0 0
27.5 200
/systems/failures/electrical/ess-tr eq 0
/systems/electrical/bus/ac-ess
/systems/electrical/sources/ess-tr/working
/systems/electrical/sources/ess-tr/output-volt
0 0
27.5 200
/systems/electrical/sources/tr-1/output-volt ne 0
/systems/electrical/sources/tr-1/output-amp ne 0
/systems/failures/electrical/tr-1 eq 0
/systems/electrical/relay/tr-contactor-1/contact-pos eq 1
/systems/electrical/relay/tr-contactor-1/contact-pos eq 1
/systems/electrical/sources/tr-2/output-volt ne 0
/systems/electrical/sources/tr-2/output-amp ne 0
/systems/failures/electrical/tr-2 eq 0
/systems/electrical/relay/tr-contactor-2/contact-pos eq 1
/systems/electrical/relay/tr-contactor-2/contact-pos eq 1
/systems/electrical/bus/ac-1 ge 110
/systems/electrical/bus/dc-1 ge 25
/systems/electrical/relay/tr-contactor-1/contact-pos eq 1
/systems/electrical/bus/dc-bat ge 25
/systems/electrical/bus/dc-bat-src ne 3
/systems/electrical/relay/tr-contactor-1/contact-pos eq 0
/systems/electrical/relay/tr-contactor-2/contact-pos eq 0
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1
/systems/electrical/relay/dc-ess-feed-bat/contact-pos eq 0
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 0
/systems/electrical/relay/tr-contactor-2/contact-pos eq 1
/systems/electrical/bus/dc-2 ge 25
/systems/electrical/bus/dc-bat ge 25
/systems/electrical/bus/dc-bat-src ne 3
/systems/electrical/relay/tr-contactor-1/contact-pos eq 0
/systems/electrical/relay/tr-contactor-2/contact-pos eq 0
/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1
/systems/electrical/relay/tr-contactor-1/output lt 25
/systems/electrical/relay/tr-contactor-2/output lt 25
/systems/electrical/relay/emer-glc/output ge 110
/systems/electrical/sources/ess-tr/output-volt ge 25
/systems/electrical/relay/dc-ess-feed-tr/contact-pos eq 1
/systems/electrical/relay/dc-ess-feed-tr/contact-pos eq 1
/systems/electrical/relay/dc-ess-feed-tr/contact-pos eq 0
/systems/electrical/relay/tr-contactor-1/contact-pos eq 1
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1
/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 0
/controls/electrical/switches/emer-gen-test eq 0
/systems/electrical/bus/dc-1 ge 25
/systems/electrical/relay/dc-ess-feed-bat/contact-pos eq 1
/systems/electrical/sources/si-1/inverter-active eq 1
/controls/electrical/switches/emer-gen-test eq 1
/systems/electrical/relay/dc-ess-shed-switch/contact-pos eq 1
/systems/electrical/relay/dc-svc-bus-contactor-tr/contact-pos eq 1
/systems/electrical/relay/dc-svc-bus-contactor-bus-2/contact-pos eq 1
Tell which source is being used for priority purpose
/systems/electrical/relay/tr-contactor-1/output ge 25
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1
/systems/failures/electrical/dc-1-bus
1
0
/systems/electrical/relay/tr-contactor-1/output
/systems/electrical/relay/dc-bus-tie-dc-1/output
Tell which source is being used for priority purpose
/systems/electrical/relay/tr-contactor-2/output ge 25
/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1
/systems/failures/electrical/dc-2-bus
1
0
/systems/electrical/relay/tr-contactor-2/output
/systems/electrical/relay/dc-bus-tie-dc-2/output
/systems/electrical/relay/dc-svc-bus-contactor-tr/output
/systems/electrical/relay/dc-svc-bus-contactor-bus-2/output
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1
/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1
Tell which source is being used for priority purpose
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1
/systems/electrical/bus/dc-1-src ne 2
/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1
/systems/electrical/bus/dc-2-src ne 2
/instrumentation/airspeed-indicator/indicated-speed-kt lt 50
/controls/electrical/switches/bat-1 eq 1
/controls/electrical/switches/bat-2 eq 1
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
/systems/failures/electrical/dc-bat-bus eq 1
/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1
/systems/electrical/bus/dc-1-src ne 2
/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1
/systems/electrical/bus/dc-2-src ne 2
/instrumentation/airspeed-indicator/indicated-speed-kt lt 50
/controls/electrical/switches/bat-1 eq 1
/systems/electrical/bus/dc-bat-src eq 3
/systems/electrical/sources/bat-1/volt ge 25
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
/instrumentation/airspeed-indicator/indicated-speed-kt lt 50
/controls/electrical/switches/bat-2 eq 1
/systems/electrical/bus/dc-bat-src eq 3
/systems/electrical/sources/bat-2/volt ge 25
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
/systems/failures/electrical/dc-ess-bus
1
0
/systems/electrical/relay/dc-ess-feed-bat/output
/systems/electrical/relay/dc-ess-feed-tr/output
/systems/electrical/bus/dc-ess
1
/systems/electrical/sources/bat-1/volt
1.0
/systems/electrical/sources/bat-2/volt
1.0
/systems/electrical/bus/ac-1 lt 110
/systems/electrical/bus/ac-2 lt 110
/systems/acconfig/autoconfig-running ne 1
/systems/acconfig/autoconfig-running ne 1
/systems/electrical/relay/ext-epc/contact-pos eq 0
/controls/electrical/switches/gen-1 eq 0
/systems/failures/electrical/gen-1 eq 1
/controls/electrical/switches/gen-2 eq 0
/systems/failures/electrical/gen-2 eq 1
/controls/electrical/switches/apu eq 0
/systems/failures/electrical/apu eq 1
/systems/apu/rpm lt 94.9
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
/controls/electrical/switches/gen-1 eq 1
/controls/electrical/switches/bus-tie eq 0
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
/controls/electrical/switches/gen-2 eq 1
/controls/electrical/switches/bus-tie eq 0
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
/controls/electrical/switches/gen-1 eq 1
/systems/electrical/some-electric-thingie/emer-elec-config eq 1
/controls/electrical/switches/gen-2 eq 1
Timer for the ECAM system
/systems/electrical/relay/ac-ess-feed-inverter/contact-pos
100
0.1
This makes the FG stuff work because we killed the generic electrical
/systems/electrical/bus/dc-1 ge 25
/systems/electrical/bus/dc-2 ge 25
/systems/electrical/bus/ac-ess lt 110
/controls/electrical/switches/apu eq 1
/systems/electrical/relay/apu-glc/contact-pos eq 0
/systems/electrical/relay/ext-epc/contact-pos eq 0
/systems/electrical/sources/apu/drive-rpm gt 2000
/systems/failures/electrical/bat-1 eq 1
/systems/failures/electrical/bat-2 eq 1
/controls/electrical/switches/gen-1 eq 1
/systems/electrical/relay/gen-1-glc/contact-pos eq 0
/controls/electrical/switches/gen-2 eq 1
/systems/electrical/relay/gen-2-glc/contact-pos eq 0
/systems/failures/electrical/idg-1 eq 1
/systems/electrical/sources/idg-1/csd-rpm gt 2000
/controls/electrical/switches/idg-1-disc-momentary eq 1
/systems/failures/electrical/idg-2 eq 1
/systems/electrical/sources/idg-2/csd-rpm gt 2000
/controls/electrical/switches/idg-2-disc-momentary eq 1
/systems/electrical/relay/dc-ess-feed-tr/output eq 0
/systems/electrical/bus/ac-1 eq 0
/systems/electrical/bus/ac-2 eq 0
position/wow eq 0