<?xml version="1.0"?> <!-- Copyright (c) 2019 Jonathan Redpath (legoboyvdlp), Joshua Davidson (Octal450) --> <system name="A320: Electrical"> <property value="0">/systems/electrical/some-electric-thingie/rat-deploy</property> <property value="0">/systems/electrical/relay/gen-1-glc/contact-pos</property> <property value="0">/systems/electrical/relay/gen-2-glc/contact-pos</property> <channel name="Main Electrical" execrate="8"> <!-- Battery 1 --> <fcs_function name="/systems/electrical/sources/bat-1/volt"> <function> <product> <difference> <value>1</value> <product> <property>/systems/electrical/sources/bat-1/amps</property> <value>0.00016666</value> </product> </difference> <table> <independentVar lookup="row">/systems/electrical/sources/bat-1/percent</independentVar> <independentVar lookup="column">/systems/failures/electrical/bat-1</independentVar> <tableData> 0 1 0 0.0 0.0 10 24.0 4.0 50 25.5 5.0 100 31.0 7.0 </tableData> </table> </product> </function> </fcs_function> <switch name="/systems/electrical/sources/bat-1/contact"> <default value="/systems/electrical/sources/bat-1/contact"/> <test logic="OR" value="0"> <!-- discharge protection or switch turned off --> /controls/electrical/switches/bat-1 eq 0 /systems/electrical/sources/bat-1/volt lt 23 /systems/electrical/sources/bat-1/amps ge 100 </test> <test logic="AND" value="1"> <!-- apu start --> /controls/electrical/switches/bat-1 eq 1 /systems/apu/start eq 1 </test> <test logic="AND" value="1"> <!-- connect to dc-bat while no other power on the ground --> /controls/electrical/switches/bat-1 eq 1 /systems/electrical/bus/ac-1 lt 110 /systems/electrical/bus/ac-2 lt 110 /gear/gear[1]/wow eq 1 /instrumentation/airspeed-indicator/indicated-speed-kt lt 100 </test> <test logic="AND" value="1"> <!-- start charging cycle --> /systems/electrical/sources/bat-1/charge eq 1 </test> <test logic="AND" value="1"> <!-- maintain charging cycle --> /systems/electrical/sources/bat-1/charge eq 1 /controls/electrical/switches/bat-1 eq 1 /systems/electrical/sources/bat-1/contact eq 1 /systems/electrical/bus/dc-bat gt 27.5 /systems/electrical/sources/bat-1/percent-calc lt 99.9 </test> <test logic="AND" value="0"> /systems/electrical/sources/bat-1/charge eq 0 </test> </switch> <switch name="/systems/electrical/sources/bat-1/charge"> <default value="/systems/electrical/sources/bat-1/charge"/> <test logic="AND" value="0"> <!-- end charging cycle --> /systems/electrical/sources/bat-1/charge eq 1 <test logic="OR"> /controls/electrical/switches/bat-1 eq 0 /systems/electrical/bus/dc-bat lt 27.5 /systems/electrical/sources/bat-1/percent-calc ge 99.9 </test> </test> <test logic="AND" value="1"> <!-- start charging cycle --> /controls/electrical/switches/bat-1 eq 1 /systems/electrical/sources/bat-1/contact eq 0 /systems/electrical/sources/bat-1/volt lt 26.5 /systems/electrical/bus/dc-bat gt 27.5 </test> </switch> <switch name="/systems/electrical/sources/bat-1/direction"> <default value="0"/> <test logic="AND" value="0"> /systems/electrical/sources/bat-1/contact eq 0 /systems/electrical/sources/si-1/inverter-active eq 0 </test> <test logic="AND" value="1"> /systems/electrical/sources/si-1/inverter-active eq 1 </test> <test logic="AND" value="1"> <!-- drain --> /systems/electrical/sources/bat-1/contact eq 1 <test logic="OR"> <test logic="AND"> /systems/electrical/bus/dc-bat-src ne 1 /systems/electrical/bus/dc-bat-src ne 2 </test> /systems/apu/start eq 1 </test> </test> <test logic="AND" value="-1"> <!-- charge --> /systems/electrical/sources/bat-1/contact eq 1 /systems/electrical/bus/dc-bat-src ne 3 </test> </switch> <fcs_function name="/systems/electrical/sources/bat-1/percent-calc"> <function> <ifthen> <eq> <property>/systems/electrical/sources/bat-1/direction</property> <value>0</value> </eq> <property>/systems/electrical/sources/bat-1/percent-calc</property> <ifthen> <eq> <property>/systems/electrical/sources/bat-1/direction</property> <value>-1</value> </eq> <sum> <property>/systems/electrical/sources/bat-1/percent</property> <product> <quotient> <value>2.25</value> <sum> <property>/systems/electrical/sources/bat-1/percent</property> <value>1</value> </sum> </quotient> <property>simulation/channel-dt</property> </product> </sum> <sum> <property>/systems/electrical/sources/bat-1/percent</property> <product> <quotient> <value>-0.75</value> <sum> <property>/systems/electrical/sources/bat-1/percent</property> <value>1</value> </sum> </quotient> <property>simulation/channel-dt</property> </product> </sum> </ifthen> </ifthen> </function> <output>/systems/electrical/sources/bat-1/percent</output> </fcs_function> <switch name="/systems/electrical/sources/bat-1/load-kw"> <default value="0"/> <test logic="AND" value="0.864"> /systems/apu/start eq 1 /systems/electrical/sources/bat-1/contact eq 1 </test> <test logic="AND" value="1.15"> <!-- 60 amp * 0.8 * 24V = 1.15kw. Guess --> /systems/electrical/bus/dc-bat-src ne 1 /systems/electrical/bus/dc-bat-src ne 2 /systems/electrical/sources/bat-1/contact eq 1 </test> </switch> <switch name="/systems/electrical/sources/bat-1/amps"> <default value="0"/> <test logic="AND" value="40"> /systems/electrical/sources/bat-1/load-kw ne 0 /systems/electrical/sources/bat-1/direction eq 1 </test> <test logic="AND" value="2"> /systems/electrical/sources/bat-1/contact eq 1 /systems/electrical/sources/bat-1/direction eq -1 </test> </switch> <!-- Battery 2 --> <fcs_function name="/systems/electrical/sources/bat-2/volt"> <function> <product> <difference> <value>1</value> <product> <property>/systems/electrical/sources/bat-2/amps</property> <value>0.00016666</value> </product> </difference> <table> <independentVar lookup="row">/systems/electrical/sources/bat-2/percent</independentVar> <independentVar lookup="column">/systems/failures/electrical/bat-2</independentVar> <tableData> 0 1 0 0.0 0.0 10 24.0 4.0 50 25.5 5.0 100 31.0 7.0 </tableData> </table> </product> </function> </fcs_function> <switch name="/systems/electrical/sources/bat-2/contact"> <default value="/systems/electrical/sources/bat-2/contact"/> <test logic="OR" value="0"> <!-- discharge protection or switch turned off --> /controls/electrical/switches/bat-2 eq 0 /systems/electrical/sources/bat-2/volt lt 23 /systems/electrical/sources/bat-2/amps ge 100 </test> <test logic="AND" value="1"> <!-- apu start --> /controls/electrical/switches/bat-2 eq 1 /systems/apu/start eq 1 </test> <test logic="AND" value="1"> <!-- connect to dc-bat while no other power on the ground --> /controls/electrical/switches/bat-2 eq 1 /systems/electrical/bus/ac-1 lt 110 /systems/electrical/bus/ac-2 lt 110 /gear/gear[1]/wow eq 1 /instrumentation/airspeed-indicator/indicated-speed-kt lt 100 </test> <test logic="AND" value="1"> <!-- start charging cycle --> /systems/electrical/sources/bat-2/charge eq 1 </test> <test logic="AND" value="1"> <!-- maintain charging cycle --> /systems/electrical/sources/bat-2/charge eq 1 /controls/electrical/switches/bat-2 eq 1 /systems/electrical/sources/bat-2/contact eq 1 /systems/electrical/bus/dc-bat gt 27.5 /systems/electrical/sources/bat-2/percent-calc lt 99.9 </test> <test logic="AND" value="0"> /systems/electrical/sources/bat-2/charge eq 0 </test> </switch> <switch name="/systems/electrical/sources/bat-2/charge"> <default value="/systems/electrical/sources/bat-2/charge"/> <test logic="AND" value="0"> <!-- end charging cycle --> /systems/electrical/sources/bat-2/charge eq 1 <test logic="OR"> /controls/electrical/switches/bat-2 eq 0 /systems/electrical/bus/dc-bat lt 27.5 /systems/electrical/sources/bat-2/percent-calc ge 99.9 </test> </test> <test logic="AND" value="1"> <!-- start charging cycle --> /controls/electrical/switches/bat-2 eq 1 /systems/electrical/sources/bat-2/contact eq 0 /systems/electrical/sources/bat-2/volt lt 26.5 /systems/electrical/bus/dc-bat gt 27.5 </test> </switch> <switch name="/systems/electrical/sources/bat-2/direction"> <default value="0"/> <test logic="AND" value="0"> /systems/electrical/sources/bat-2/contact eq 0 /systems/electrical/sources/si-1/inverter-active eq 0 </test> <test logic="AND" value="1"> /systems/electrical/sources/si-1/inverter-active eq 1 </test> <test logic="AND" value="1"> <!-- drain --> /systems/electrical/sources/bat-2/contact eq 1 <test logic="OR"> <test logic="AND"> /systems/electrical/bus/dc-bat-src ne 1 /systems/electrical/bus/dc-bat-src ne 2 </test> /systems/apu/start eq 1 </test> </test> <test logic="AND" value="-1"> <!-- charge --> /systems/electrical/sources/bat-2/contact eq 1 /systems/electrical/bus/dc-bat-src ne 3 </test> </switch> <fcs_function name="/systems/electrical/sources/bat-2/percent-calc"> <function> <ifthen> <eq> <property>/systems/electrical/sources/bat-2/direction</property> <value>0</value> </eq> <property>/systems/electrical/sources/bat-2/percent-calc</property> <ifthen> <eq> <property>/systems/electrical/sources/bat-2/direction</property> <value>-1</value> </eq> <sum> <property>/systems/electrical/sources/bat-2/percent</property> <product> <quotient> <value>2.25</value> <sum> <property>/systems/electrical/sources/bat-2/percent</property> <value>1</value> </sum> </quotient> <property>simulation/channel-dt</property> </product> </sum> <sum> <property>/systems/electrical/sources/bat-2/percent</property> <product> <quotient> <value>-0.75</value> <sum> <property>/systems/electrical/sources/bat-2/percent</property> <value>1</value> </sum> </quotient> <property>simulation/channel-dt</property> </product> </sum> </ifthen> </ifthen> </function> <output>/systems/electrical/sources/bat-2/percent</output> </fcs_function> <switch name="/systems/electrical/sources/bat-2/load-kw"> <default value="0"/> <test logic="AND" value="0.864"> /systems/apu/start eq 1 /systems/electrical/sources/bat-2/contact eq 1 </test> <test logic="AND" value="1.15"> <!-- 60 amp * 0.8 * 24V = 1.15kw. Guess --> /systems/electrical/bus/dc-bat-src ne 1 /systems/electrical/bus/dc-bat-src ne 2 /systems/electrical/sources/bat-2/contact eq 1 </test> </switch> <switch name="/systems/electrical/sources/bat-2/amps"> <default value="0"/> <test logic="AND" value="40"> /systems/electrical/sources/bat-2/load-kw ne 0 /systems/electrical/sources/bat-2/direction eq 1 </test> <test logic="AND" value="2"> /systems/electrical/sources/bat-2/contact eq 1 /systems/electrical/sources/bat-2/direction eq -1 </test> </switch> <!-- IDG 1 --> <pure_gain name="/systems/electrical/sources/idg-1/drive-rpm-input"> <input>/engines/engine[0]/n2-actual</input> <gain>90.298</gain> <!-- 1% N2 RPM value * 0.604 --> </pure_gain> <switch name="/systems/electrical/sources/idg-1/working"> <default value="1"/> <test logic="OR" value="0"> /systems/failures/electrical/idg-1 eq 1 /controls/electrical/switches/idg-1-disc eq 0 </test> </switch> <pure_gain name="/systems/electrical/sources/idg-1/drive-rpm"> <input>/systems/electrical/sources/idg-1/drive-rpm-input</input> <gain>/systems/electrical/sources/idg-1/working</gain> </pure_gain> <fcs_function name="/systems/electrical/sources/idg-1/csd-gearbox-ratio-cmd"> <function> <quotient> <value>12000</value> <property>/systems/electrical/sources/idg-1/drive-rpm</property> </quotient> </function> <clipto> <min>1.315</min> <max>2.667</max> </clipto> </fcs_function> <lag_filter name="/systems/electrical/sources/idg-1/csd-gearbox-ratio"> <input>/systems/electrical/sources/idg-1/csd-gearbox-ratio-cmd</input> <c1>40</c1> </lag_filter> <pure_gain name="/systems/electrical/sources/idg-1/csd-rpm"> <input>/systems/electrical/sources/idg-1/drive-rpm</input> <gain>/systems/electrical/sources/idg-1/csd-gearbox-ratio</gain> </pure_gain> <fcs_function name="/systems/electrical/sources/idg-1/pmg-volt"> <function> <product> <property>/systems/electrical/sources/idg-1/csd-rpm</property> <quotient> <value>115</value> <value>12000</value> </quotient> </product> </function> </fcs_function> <fcs_function name="/systems/electrical/sources/idg-1/pmg-hertz"> <function> <quotient> <product> <property>/systems/electrical/sources/idg-1/csd-rpm</property> <value>4</value> <!-- Number of poles in generator --> </product> <value>120</value> </quotient> </function> </fcs_function> <switch name="/systems/electrical/sources/idg-1/gcr-relay"> <default value="0"/> <test logic="AND" value="1"> /systems/failures/electrical/gen-1 ne 1 /controls/engines/engine[0]/fire-btn eq 0 /systems/electrical/sources/idg-1/drive-rpm ge 4730 </test> </switch> <pure_gain name="/systems/electrical/sources/idg-1/output-volt"> <input>/systems/electrical/sources/idg-1/pmg-volt</input> <gain>/systems/electrical/sources/idg-1/gcr-relay</gain> </pure_gain> <pure_gain name="/systems/electrical/sources/idg-1/output-hertz"> <input>/systems/electrical/sources/idg-1/pmg-hertz</input> <gain>/systems/electrical/sources/idg-1/gcr-relay</gain> </pure_gain> <!-- IDG 2 --> <pure_gain name="/systems/electrical/sources/idg-2/drive-rpm-input"> <input>/engines/engine[1]/n2-actual</input> <gain>90.298</gain> <!-- 1% N2 RPM value * 0.604 --> </pure_gain> <switch name="/systems/electrical/sources/idg-2/working"> <default value="1"/> <test logic="OR" value="0"> /systems/failures/electrical/idg-2 eq 1 /controls/electrical/switches/idg-2-disc eq 0 </test> </switch> <pure_gain name="/systems/electrical/sources/idg-2/drive-rpm"> <input>/systems/electrical/sources/idg-2/drive-rpm-input</input> <gain>/systems/electrical/sources/idg-2/working</gain> </pure_gain> <fcs_function name="/systems/electrical/sources/idg-2/csd-gearbox-ratio-cmd"> <function> <quotient> <value>12000</value> <property>/systems/electrical/sources/idg-2/drive-rpm</property> </quotient> </function> <clipto> <min>1.315</min> <max>2.667</max> </clipto> </fcs_function> <lag_filter name="/systems/electrical/sources/idg-2/csd-gearbox-ratio"> <input>/systems/electrical/sources/idg-2/csd-gearbox-ratio-cmd</input> <c1>40</c1> </lag_filter> <pure_gain name="/systems/electrical/sources/idg-2/csd-rpm"> <input>/systems/electrical/sources/idg-2/drive-rpm</input> <gain>/systems/electrical/sources/idg-2/csd-gearbox-ratio</gain> </pure_gain> <fcs_function name="/systems/electrical/sources/idg-2/pmg-volt"> <function> <product> <property>/systems/electrical/sources/idg-2/csd-rpm</property> <quotient> <value>115</value> <value>12000</value> </quotient> </product> </function> </fcs_function> <fcs_function name="/systems/electrical/sources/idg-2/pmg-hertz"> <function> <quotient> <product> <property>/systems/electrical/sources/idg-2/csd-rpm</property> <value>4</value> <!-- Number of poles in generator --> </product> <value>120</value> </quotient> </function> </fcs_function> <switch name="/systems/electrical/sources/idg-2/gcr-relay"> <default value="0"/> <test logic="AND" value="1"> /systems/failures/electrical/gen-2 ne 1 /controls/engines/engine[1]/fire-btn eq 0 /systems/electrical/sources/idg-2/drive-rpm ge 4730 </test> </switch> <pure_gain name="/systems/electrical/sources/idg-2/output-volt"> <input>/systems/electrical/sources/idg-2/pmg-volt</input> <gain>/systems/electrical/sources/idg-2/gcr-relay</gain> </pure_gain> <pure_gain name="/systems/electrical/sources/idg-2/output-hertz"> <input>/systems/electrical/sources/idg-2/pmg-hertz</input> <gain>/systems/electrical/sources/idg-2/gcr-relay</gain> </pure_gain> <!-- APU gen --> <pure_gain name="/systems/electrical/sources/apu/drive-rpm"> <input>/engines/engine[2]/n1</input> <gain>240.34</gain> </pure_gain> <fcs_function name="/systems/electrical/sources/apu/pmg-volt"> <function> <product> <property>/systems/electrical/sources/apu/drive-rpm</property> <quotient> <value>115</value> <value>24000</value> </quotient> </product> </function> </fcs_function> <fcs_function name="/systems/electrical/sources/apu/pmg-hertz"> <function> <quotient> <product> <property>/systems/electrical/sources/apu/drive-rpm</property> <value>2</value> <!-- Number of poles in generator --> </product> <value>120</value> </quotient> </function> </fcs_function> <switch name="/systems/electrical/sources/apu/gcr-relay"> <default value="0"/> <test logic="AND" value="1"> /controls/apu/fire-btn ne 1 /controls/electrical/switches/apu eq 1 /systems/failures/electrical/apu ne 1 /systems/electrical/sources/apu/drive-rpm ge 22800 </test> </switch> <pure_gain name="/systems/electrical/sources/apu/output-volt"> <input>/systems/electrical/sources/apu/pmg-volt</input> <gain>/systems/electrical/sources/apu/gcr-relay</gain> </pure_gain> <pure_gain name="/systems/electrical/sources/apu/output-hertz"> <input>/systems/electrical/sources/apu/pmg-hertz</input> <gain>/systems/electrical/sources/apu/gcr-relay</gain> </pure_gain> <!-- External Power --> <fcs_function name="/systems/electrical/sources/ext/output-volt"> <function> <ifthen> <eq> <property>/controls/electrical/ground-cart</property> <value>1</value> </eq> <value>115</value> <value>0</value> </ifthen> </function> </fcs_function> <fcs_function name="/systems/electrical/sources/ext/output-hertz"> <function> <ifthen> <ge> <property>/systems/electrical/sources/ext/output-volt</property> <value>110</value> </ge> <value>400</value> <value>0</value> </ifthen> </function> </fcs_function> <!-- Static Inverter --> <switch name="/systems/electrical/sources/si-1/inverter-active"> <default value="0"/> <test value="0"> /systems/failures/electrical/stat-inv eq 1 </test> <test logic="AND" value="1"> /systems/electrical/some-electric-thingie/emer-gen-operate eq 1 /systems/electrical/sources/emer-gen/coupled ne 1 </test> <test logic="AND" value="1"> /instrumentation/airspeed-indicator/indicated-speed-kt lt 100 /instrumentation/airspeed-indicator/indicated-speed-kt ge 50 /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /sim/time/elapsed-sec gt 10 </test> <test logic="AND" value="1"> /instrumentation/airspeed-indicator/indicated-speed-kt lt 50 /controls/electrical/switches/bat-1 eq 1 /controls/electrical/switches/bat-2 eq 1 /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /sim/time/elapsed-sec gt 10 </test> </switch> <fcs_function name="/systems/electrical/sources/si-1/inverter-gain"> <function> <ifthen> <eq> <property>/systems/electrical/sources/si-1/inverter-active</property> <value>1</value> </eq> <quotient> <value>115</value> <property>/systems/electrical/sources/bat-1/volt</property> </quotient> <value>0</value> </ifthen> </function> </fcs_function> <pure_gain name="/systems/electrical/sources/si-1/output-volt"> <input>/systems/electrical/sources/bat-1/volt</input> <!-- inverter feeds directly from batteries --> <gain>/systems/electrical/sources/si-1/inverter-gain</gain> </pure_gain> <switch name="/systems/electrical/sources/si-1/fault"> <default value="0"/> <test logic="OR" value="1"> /systems/electrical/sources/bat-1/volt lt 23.5 /systems/electrical/sources/si-1/output-volt lt 110 /systems/electrical/sources/si-1/output-volt ge 120 </test> </switch> <switch name="/systems/electrical/sources/si-1/output-hertz"> <default value="0"/> <test logic="AND" value="400"> /systems/electrical/sources/si-1/output-volt ge 110 </test> </switch> <!-- Emergency Generator --> <switch name="/systems/electrical/some-electric-thingie/rat-deploy"> <default value="/systems/electrical/some-electric-thingie/rat-deploy"/> <test logic="AND" value="1"> /instrumentation/airspeed-indicator/indicated-speed-kt gt 100 /sim/time/elapsed-sec gt 30 /systems/electrical/bus/ac-1 eq 0 /systems/electrical/bus/ac-2 eq 0 /controls/electrical/switches/emer-elec-man-on eq 0 </test> <test logic="OR" value="1"> /controls/hydraulic/switches/rat-man eq 1 /controls/electrical/switches/emer-elec-man-on eq 1 </test> <!--<test value="0"> /controls/hydraulic/switches/ground-rat-retraction eq 1 </test>--> </switch> <switch name="/systems/electrical/some-electric-thingie/emer-gen-operate"> <default value="0"/> <test logic="AND" value="1"> /controls/electrical/switches/emer-gen-test eq 1 /systems/electrical/bus/ac-1 ne 0 /systems/electrical/bus/ac-2 ne 0 </test> <test logic="AND" value="1"> /instrumentation/airspeed-indicator/indicated-speed-kt ge 100 /systems/electrical/bus/ac-1 eq 0 /systems/electrical/bus/ac-2 eq 0 gear/unit[0]/WOW eq 0 /controls/electrical/switches/emer-elec-man-on eq 0 </test> <test logic="AND" value="1"> gear/unit[0]/WOW eq 0 /controls/electrical/switches/emer-elec-man-on eq 1 </test> </switch> <switch name="/systems/electrical/some-electric-thingie/emer-gen-operating-on-rat"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/some-electric-thingie/emer-gen-operate eq 1 /systems/hydraulic/sources/rat/position eq 1 </test> <test logic="AND" value="1"> /controls/electrical/switches/emer-gen-test eq 1 /systems/electrical/bus/ac-1 ne 0 /systems/electrical/bus/ac-2 ne 0 </test> </switch> <kinematic name="/systems/electrical/sources/emer-gen/coupled-kin"> <input>/systems/electrical/some-electric-thingie/emer-gen-operating-on-rat</input> <traverse> <setting> <position>0.0</position> <time>0.0</time> </setting> <setting> <position>1.0</position> <time>5.5</time> </setting> </traverse> </kinematic> <switch name="/systems/electrical/sources/emer-gen/coupled"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/sources/emer-gen/coupled-kin eq 1 /systems/failures/electrical/emer-gen ne 1 </test> <test logic="AND" value="1"> /controls/electrical/switches/emer-gen-test eq 1 /systems/failures/electrical/emer-gen ne 1 /systems/electrical/bus/ac-1 ne 0 /systems/electrical/bus/ac-2 ne 0 </test> </switch> <!-- Regulated to 115V, no point doing fancy, HYD controls it --> <switch name="/systems/electrical/sources/emer-gen/output-volt"> <default value="0"/> <test logic="AND" value="115"> /systems/electrical/some-electric-thingie/emer-gen-operate eq 1 /systems/electrical/sources/emer-gen/coupled eq 1 /systems/hydraulic/blue-psi ge 2500 /systems/failures/electrical/emer-gen eq 0 </test> </switch> <switch name="/systems/electrical/sources/emer-gen/output-hertz"> <default value="0"/> <test logic="AND" value="400"> /systems/electrical/sources/emer-gen/output-volt ge 110 </test> </switch> <!-- Source Relays --> <switch name="/systems/electrical/sources/idg-1/gcu-1-powered"> <default value="0"/> <test logic="OR" value="1"> /systems/electrical/bus/dc-bat ge 25 /systems/electrical/sources/idg-1/pmg-volt ge 110 </test> </switch> <switch name="/systems/electrical/sources/idg-1/gcu-1-voltage-trip"> <default value="0"/> <test logic="AND" value="1"> /systems/acconfig/autoconfig-running ne 1 /systems/electrical/sources/idg-1/gcu-1-voltage-trip eq 1 /controls/electrical/switches/gen-1 eq 1 </test> <test logic="AND" value="1"> /systems/electrical/relay/gen-1-glc/contact-pos eq 1 <test logic="OR"> /systems/electrical/sources/idg-1/output-volt lt 110 /systems/electrical/sources/idg-1/output-volt gt 130 </test> </test> </switch> <switch name="/systems/electrical/sources/idg-1/gcu-1-frequency-trip"> <default value="0"/> <test logic="AND" value="1"> /systems/acconfig/autoconfig-running ne 1 /systems/electrical/sources/idg-1/gcu-1-frequency-trip eq 1 /controls/electrical/switches/gen-1 eq 1 </test> <test logic="AND" value="1"> /systems/electrical/relay/gen-1-glc/contact-pos eq 1 <test logic="OR"> /systems/electrical/sources/idg-1/output-hertz lt 363 /systems/electrical/sources/idg-1/output-hertz gt 433 </test> </test> </switch> <switch name="/systems/electrical/sources/idg-1/gcu-1-fault"> <default value="0"/> <test logic="OR" value="0"> /systems/acconfig/autoconfig-running eq 1 /sim/time/elapsed-sec lt 10 </test> <test logic="OR" value="1"> /systems/electrical/sources/idg-1/gcu-1-voltage-trip eq 1 /systems/electrical/sources/idg-1/gcu-1-frequency-trip eq 1 /systems/electrical/sources/idg-1/drive-rpm lt 4730 </test> </switch> <switch name="/systems/electrical/relay/gen-1-glc/contact-pos"> <default value="0"/> <test logic="OR" value="0"> /sim/time/elapsed-sec lt 10 </test> <test logic="AND" value="1"> /controls/electrical/switches/gen-1 eq 1 /systems/electrical/sources/idg-1/output-hertz ge 363 /systems/electrical/sources/idg-1/output-hertz le 433 /systems/electrical/sources/idg-1/output-volt ge 110 /systems/electrical/sources/idg-1/output-volt le 130 /systems/electrical/sources/idg-1/gcu-1-fault ne 1 <!-- software trip --> </test> </switch> <switch name="/systems/electrical/relay/gen-1-glc/output"> <default value="0"/> <test value="/systems/electrical/sources/idg-1/output-volt"> /systems/electrical/relay/gen-1-glc/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/sources/idg-2/gcu-2-powered"> <default value="0"/> <test logic="OR" value="1"> /systems/electrical/bus/dc-bat ge 25 /systems/electrical/sources/idg-2/pmg-volt ge 110 </test> </switch> <switch name="/systems/electrical/sources/idg-2/gcu-2-voltage-trip"> <default value="0"/> <test logic="AND" value="1"> /systems/acconfig/autoconfig-running ne 1 /systems/electrical/sources/idg-2/gcu-2-voltage-trip eq 1 /controls/electrical/switches/gen-2 eq 1 </test> <test logic="AND" value="1"> /systems/electrical/relay/gen-2-glc/contact-pos eq 1 <test logic="OR"> /systems/electrical/sources/idg-2/output-volt lt 110 /systems/electrical/sources/idg-2/output-volt gt 130 </test> </test> </switch> <switch name="/systems/electrical/sources/idg-2/gcu-2-frequency-trip"> <default value="0"/> <test logic="AND" value="1"> /systems/acconfig/autoconfig-running ne 1 /systems/electrical/sources/idg-2/gcu-2-frequency-trip eq 1 /controls/electrical/switches/gen-2 eq 1 </test> <test logic="AND" value="1"> /systems/electrical/relay/gen-2-glc/contact-pos eq 1 <test logic="OR"> /systems/electrical/sources/idg-2/output-hertz lt 363 /systems/electrical/sources/idg-2/output-hertz gt 433 </test> </test> </switch> <switch name="/systems/electrical/sources/idg-2/gcu-2-fault"> <default value="0"/> <test logic="OR" value="0"> /systems/acconfig/autoconfig-running eq 1 /sim/time/elapsed-sec lt 10 </test> <test logic="OR" value="1"> /systems/electrical/sources/idg-2/gcu-2-voltage-trip eq 1 /systems/electrical/sources/idg-2/gcu-2-frequency-trip eq 1 /systems/electrical/sources/idg-2/drive-rpm lt 4730 </test> </switch> <switch name="/systems/electrical/relay/gen-2-glc/contact-pos"> <default value="0"/> <test logic="OR" value="0"> /sim/time/elapsed-sec lt 10 </test> <test logic="AND" value="1"> /controls/electrical/switches/gen-2 eq 1 /systems/electrical/sources/idg-2/output-hertz ge 363 /systems/electrical/sources/idg-2/output-hertz le 433 /systems/electrical/sources/idg-2/output-volt ge 110 /systems/electrical/sources/idg-2/output-volt le 130 /systems/electrical/sources/idg-2/gcu-2-fault ne 1 <!-- software trip --> </test> </switch> <switch name="/systems/electrical/relay/gen-2-glc/output"> <default value="0"/> <test value="/systems/electrical/sources/idg-2/output-volt"> /systems/electrical/relay/gen-2-glc/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/ext-epc/contact-pos"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/sources/ext/output-volt ge 110 /controls/electrical/switches/ext-pwr eq 1 /controls/electrical/ground-cart eq 1 </test> </switch> <switch name="/systems/electrical/relay/ext-epc/output"> <default value="0"/> <test value="/systems/electrical/sources/ext/output-volt"> /systems/electrical/relay/ext-epc/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/sources/apu/gcu-powered"> <default value="0"/> <test logic="OR" value="1"> /systems/electrical/bus/dc-bat ge 25 /systems/electrical/sources/apu/pmg-volt ge 101.5 </test> </switch> <switch name="/systems/electrical/sources/apu/gcu-voltage-trip"> <default value="0"/> <test logic="AND" value="1"> /systems/acconfig/autoconfig-running ne 1 /systems/electrical/sources/apu/gcu-voltage-trip eq 1 /controls/electrical/switches/apu eq 1 </test> <test logic="AND" value="1"> /systems/electrical/relay/apu-glc/contact-pos eq 1 <test logic="OR"> /systems/electrical/sources/apu/output-volt lt 101.5 /systems/electrical/sources/apu/output-volt gt 130 </test> </test> </switch> <switch name="/systems/electrical/sources/apu/gcu-frequency-trip"> <default value="0"/> <test logic="AND" value="1"> /systems/acconfig/autoconfig-running ne 1 /systems/electrical/sources/apu/gcu-frequency-trip eq 1 /controls/electrical/switches/apu eq 1 </test> <test logic="AND" value="1"> /systems/electrical/relay/apu-glc/contact-pos eq 1 <test logic="OR"> /systems/electrical/sources/apu/output-hertz lt 361 /systems/electrical/sources/apu/output-hertz gt 435 </test> </test> </switch> <switch name="/systems/electrical/sources/apu/gcu-fault"> <default value="0"/> <test logic="OR" value="0"> /systems/acconfig/autoconfig-running eq 1 /sim/time/elapsed-sec lt 10 </test> <test logic="OR" value="1"> /systems/electrical/sources/apu/gcu-voltage-trip eq 1 /systems/electrical/sources/apu/gcu-frequency-trip eq 1 </test> </switch> <switch name="/systems/electrical/relay/apu-glc/contact-pos"> <default value="0"/> <test logic="OR" value="0"> /sim/time/elapsed-sec lt 10 </test> <test logic="AND" value="1"> /controls/apu/master eq 1 /controls/electrical/switches/apu eq 1 /systems/electrical/sources/apu/output-volt ge 101.5 /systems/electrical/sources/apu/output-volt le 130 /systems/electrical/sources/apu/output-hertz ge 361 /systems/electrical/sources/apu/output-hertz le 435 /systems/electrical/relay/ext-epc/contact-pos eq 0 /systems/electrical/sources/apu/gcu-fault ne 1 <!-- software trip --> </test> </switch> <switch name="/systems/electrical/relay/apu-glc/output"> <default value="0"/> <test value="/systems/electrical/sources/apu/output-volt"> /systems/electrical/relay/apu-glc/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/emer-glc/contact-pos"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/sources/emer-gen/output-volt ge 110 /systems/failures/electrical/emer-gen ne 1 /systems/electrical/relay/ac-ess-feed-1/output lt 110 /systems/electrical/relay/ac-ess-feed-2/output lt 110 </test> </switch> <switch name="/systems/electrical/relay/emer-glc/output"> <default value="0"/> <test value="/systems/electrical/sources/emer-gen/output-volt"> /systems/electrical/relay/emer-glc/contact-pos eq 1 </test> </switch> <!-- AC Bus Tie AC Bus Relays --> <!-- These outputs are from the AC Bus Tie to the AC Bus --> <switch name="/systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos"> <default value="0"/> <test value="0"> /controls/electrical/switches/bus-tie eq 0 </test> <test logic="AND" value="1"> /systems/electrical/relay/gen-1-glc/contact-pos eq 1 /systems/electrical/relay/gen-2-glc/contact-pos eq 0 /systems/electrical/relay/apu-glc/contact-pos eq 0 /systems/electrical/relay/ext-epc/contact-pos eq 0 /controls/electrical/switches/bus-tie eq 1 </test> <test logic="AND" value="1"> /systems/electrical/relay/gen-1-glc/contact-pos eq 0 /systems/electrical/bus/ac-bus-tie ge 110 /controls/electrical/switches/bus-tie eq 1 </test> </switch> <switch name="/systems/electrical/relay/ac-bus-ac-bus-tie-1/output"> <default value="0"/> <test value="/systems/electrical/bus/ac-bus-tie"> /systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos"> <default value="0"/> <test value="0"> /controls/electrical/switches/bus-tie eq 0 </test> <test logic="AND" value="1"> /systems/electrical/relay/gen-2-glc/contact-pos eq 1 /systems/electrical/relay/gen-1-glc/contact-pos eq 0 /systems/electrical/relay/apu-glc/contact-pos eq 0 /systems/electrical/relay/ext-epc/contact-pos eq 0 /controls/electrical/switches/bus-tie eq 1 </test> <test logic="AND" value="1"> /systems/electrical/relay/gen-2-glc/contact-pos eq 0 /systems/electrical/bus/ac-bus-tie ge 110 /controls/electrical/switches/bus-tie eq 1 </test> </switch> <switch name="/systems/electrical/relay/ac-bus-ac-bus-tie-2/output"> <default value="0"/> <test value="/systems/electrical/bus/ac-bus-tie"> /systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1 </test> </switch> <!-- AC ESS Relays --> <switch name="/systems/electrical/relay/ac-ess-feed-1/auto-switch"> <default value="0"/> <test logic="OR" value="1"> /systems/electrical/bus/ac-1 lt 110 </test> </switch> <actuator name="/systems/electrical/relay/ac-ess-feed-1/auto-switch-timer"> <input>/systems/electrical/relay/ac-ess-feed-1/auto-switch</input> <rate_limit sense="decr">120</rate_limit> <!-- Instant --> <rate_limit sense="incr">0.33333333333</rate_limit> <!-- 3 seconds --> </actuator> <switch name="/systems/electrical/relay/ac-ess-feed-1/contact-pos"> <!-- TODO: via 1XC CB on 123VU --> <default value="0"/> <test logic="AND" value="1"> <!-- old AC ESS FEED supply mode --> /controls/electrical/switches/ac-ess-feed eq 0 /systems/electrical/relay/ac-ess-feed-1/auto-switch-timer lt 1 /controls/electrical/switches/emer-gen-test eq 0 </test> </switch> <switch name="/systems/electrical/relay/ac-ess-feed-1/output"> <default value="0"/> <test value="/systems/electrical/bus/ac-1"> /systems/electrical/relay/ac-ess-feed-1/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/ac-ess-feed-2/contact-pos"> <!-- TODO: via 2XC CB on 123VU --> <default value="0"/> <test logic="AND" value="1"> <!-- old AC ESS FEED supply mode --> <test logic="OR"> /controls/electrical/switches/ac-ess-feed eq 1 /systems/electrical/relay/ac-ess-feed-1/auto-switch-timer eq 1 </test> /controls/electrical/switches/emer-gen-test eq 0 </test> </switch> <switch name="/systems/electrical/relay/ac-ess-feed-2/output"> <default value="0"/> <test value="/systems/electrical/bus/ac-2"> /systems/electrical/relay/ac-ess-feed-2/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/ac-ess-feed-emer-gen/contact-pos"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/bus/ac-1 eq 0 /systems/electrical/bus/ac-2 eq 0 /systems/electrical/relay/emer-glc/output ge 110 </test> <test logic="AND" value="1"> /systems/electrical/bus/ac-1 ne 0 /systems/electrical/bus/ac-2 ne 0 /controls/electrical/switches/emer-gen-test eq 1 /systems/electrical/relay/emer-glc/output ge 110 </test> </switch> <switch name="/systems/electrical/relay/ac-ess-feed-emer-gen/output"> <default value="0"/> <test value="/systems/electrical/relay/emer-glc/output"> /systems/electrical/relay/ac-ess-feed-emer-gen/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/ac-ess-feed-inverter/contact-pos"> <default value="0"/> <test logic="AND" value="1"> /instrumentation/airspeed-indicator/indicated-speed-kt ge 50 /systems/electrical/bus/ac-1 eq 0 /systems/electrical/bus/ac-2 eq 0 /controls/electrical/switches/emer-gen-test eq 0 /systems/electrical/relay/emer-glc/output lt 110 </test> </switch> <switch name="/systems/electrical/relay/ac-ess-feed-inverter/output"> <default value="0"/> <test value="/systems/electrical/sources/si-1/output-volt"> /systems/electrical/relay/ac-ess-feed-inverter/contact-pos eq 1 </test> </switch> <!-- AC ESS Shedding --> <switch name="/systems/electrical/relay/ac-ess-shed-switch/contact-pos"> <default value="1"/> <test logic="OR" value="0"> <!-- TODO: confirm these conditions are for galley, NOT ESS --> /systems/electrical/sources/si-1/inverter-active eq 1 /controls/electrical/switches/emer-gen-test eq 1 </test> </switch> <switch name="/systems/electrical/relay/ac-ess-shed-switch/output"> <default value="0"/> <test value="/systems/electrical/bus/ac-ess"> /systems/electrical/relay/ac-ess-shed-switch/contact-pos eq 1 </test> </switch> <!-- Galleys --> <fcs_function name="/systems/electrical/some-electric-thingie/galley-shed-sum"> <function> <sum> <property>/systems/electrical/relay/apu-glc/contact-pos</property> <property>/systems/electrical/relay/ext-epc/contact-pos</property> <property>/systems/electrical/relay/gen-1-glc/contact-pos</property> <property>/systems/electrical/relay/gen-2-glc/contact-pos</property> </sum> </function> </fcs_function> <switch name="/systems/electrical/relay/galley-bus-1-shed-switch/contact-pos"> <default value="0"/> <test logic="AND" value="1"> /controls/electrical/switches/galley eq 1 <test logic="OR"> <test logic="AND"> /gear/gear[1]/wow eq 0 /systems/electrical/some-electric-thingie/galley-shed-sum gt 1 </test> <test logic="AND"> /gear/gear[1]/wow eq 1 <test logic="OR"> /systems/electrical/relay/apu-glc/output ge 110 /systems/electrical/relay/ext-epc/output ge 110 <test logic="AND"> /systems/electrical/relay/gen-1-glc/output ge 110 /systems/electrical/relay/gen-2-glc/output ge 110 </test> </test> </test> </test> </test> </switch> <switch name="/systems/electrical/relay/galley-bus-1-shed-switch/output"> <default value="0"/> <test value="/systems/electrical/bus/ac-1"> /systems/electrical/relay/galley-bus-1-shed-switch/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/galley-bus-2-shed-switch/contact-pos"> <default value="0"/> <test logic="AND" value="1"> /controls/electrical/switches/galley eq 1 <test logic="OR"> <test logic="AND"> /gear/gear[1]/wow eq 0 /systems/electrical/some-electric-thingie/galley-shed-sum gt 1 </test> <test logic="AND"> /gear/gear[1]/wow eq 1 <test logic="OR"> /systems/electrical/relay/apu-glc/output ge 110 /systems/electrical/relay/ext-epc/output ge 110 <test logic="AND"> /systems/electrical/relay/gen-1-glc/output ge 110 /systems/electrical/relay/gen-2-glc/output ge 110 </test> </test> </test> </test> </test> </switch> <switch name="/systems/electrical/relay/galley-bus-2-shed-switch/output"> <default value="0"/> <test value="/systems/electrical/bus/ac-2"> /systems/electrical/relay/galley-bus-2-shed-switch/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/some-electric-thingie/galley-shed"> <default value="0"/> <test logic="OR" value="1"> /systems/electrical/relay/galley-bus-1-shed-switch/contact-pos eq 0 /systems/electrical/relay/galley-bus-2-shed-switch/contact-pos eq 0 </test> </switch> <!-- AC Bus 1 --> <switch name="/systems/electrical/bus/ac-1-src"> <description>Tell which source is being used for priority purpose</description> <default value="0"/> <!-- OFF --> <test value="1"> <!-- IDG1 --> /systems/electrical/relay/gen-1-glc/contact-pos eq 1 </test> <test value="2"> <!-- Bus Tie --> /systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1 </test> </switch> <fcs_function name="/systems/electrical/bus/ac-1"> <function> <ifthen> <eq> <property>/systems/failures/electrical/ac-1-bus</property> <value>1</value> </eq> <value>0</value> <max> <property>/systems/electrical/relay/gen-1-glc/output</property> <property>/systems/electrical/relay/ac-bus-ac-bus-tie-1/output</property> </max> </ifthen> </function> </fcs_function> <!-- AC Bus 2 --> <switch name="/systems/electrical/bus/ac-2-src"> <description>Tell which source is being used for priority purpose</description> <default value="0"/> <!-- OFF --> <test value="1"> <!-- IDG2 --> /systems/electrical/relay/gen-2-glc/contact-pos eq 1 </test> <test value="2"> <!-- Bus Tie --> /systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1 </test> </switch> <fcs_function name="/systems/electrical/bus/ac-2"> <function> <ifthen> <eq> <property>/systems/failures/electrical/ac-2-bus</property> <value>1</value> </eq> <value>0</value> <max> <property>/systems/electrical/relay/gen-2-glc/output</property> <property>/systems/electrical/relay/ac-bus-ac-bus-tie-2/output</property> </max> </ifthen> </function> </fcs_function> <pure_gain name="/systems/electrical/bus/ac-1-26v"> <!-- TODO: via 5XN1 CB on 123VU, supplies ADIRS --> <input>/systems/electrical/bus/ac-1</input> <gain>0.2260869565</gain> </pure_gain> <pure_gain name="/systems/electrical/bus/ac-2-26v"> <!-- TODO: via 5XN2 CB on 123VU, supplies ADIRS --> <input>/systems/electrical/bus/ac-2</input> <gain>0.2260869565</gain> </pure_gain> <pure_gain name="/systems/electrical/bus/ac-ess-26v"> <!-- TODO: via 4XH CB on 106VU --> <input>/systems/electrical/bus/ac-ess</input> <gain>0.2260869565</gain> </pure_gain> <pure_gain name="/systems/electrical/bus/ac-si-bus"> <!-- feeds landing gear indication, apu fuel pump, some annunciators, a injectors if RAT is out, only if stat inv is on --> <input>/systems/electrical/sources/si-1/output-volt</input> <!-- TODO: via 12XB CB on 105VU --> <gain>1</gain> </pure_gain> <fcs_function name="/systems/electrical/bus/ac-ess"> <function> <ifthen> <eq> <property>/systems/failures/electrical/ac-ess-bus</property> <value>1</value> </eq> <value>0</value> <max> <property>/systems/electrical/relay/ac-ess-feed-1/output</property> <property>/systems/electrical/relay/ac-ess-feed-2/output</property> <property>/systems/electrical/relay/ac-ess-feed-emer-gen/output</property> <property>/systems/electrical/relay/ac-ess-feed-inverter/output</property> </max> </ifthen> </function> </fcs_function> <pure_gain name="/systems/electrical/bus/ac-ess-shed"> <input>/systems/electrical/relay/ac-ess-shed-switch/output</input> <gain>/systems/electrical/relay/ac-ess-shed-switch/contact-pos</gain> </pure_gain> <!-- AC Bus Tie AC Bus Relays (continued) --> <!-- These outputs are from the AC Bus to the AC Bus Tie --> <switch name="/systems/electrical/relay/ac-bus-ac-bus-tie-1/output-tie"> <default value="0"/> <test value="/systems/electrical/bus/ac-1"> /systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/ac-bus-ac-bus-tie-2/output-tie"> <default value="0"/> <test value="/systems/electrical/bus/ac-2"> /systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1 </test> </switch> <!-- AC Bus Tie --> <switch name="/systems/electrical/bus/ac-bus-tie"> <default value="0"/> <test value="/systems/electrical/relay/ext-epc/output"> /systems/electrical/relay/ext-epc/contact-pos eq 1 </test> <test value="/systems/electrical/relay/apu-glc/output"> /systems/electrical/relay/apu-glc/contact-pos eq 1 </test> <test logic="AND" value="/systems/electrical/relay/ac-bus-ac-bus-tie-1/output-tie"> /systems/electrical/relay/ac-bus-ac-bus-tie-1/contact-pos eq 1 /systems/electrical/bus/ac-1-src ne 2 </test> <test logic="AND" value="/systems/electrical/relay/ac-bus-ac-bus-tie-2/output-tie"> /systems/electrical/relay/ac-bus-ac-bus-tie-2/contact-pos eq 1 /systems/electrical/bus/ac-2-src ne 2 </test> </switch> <!-- Transformer Rectifiers --> <pure_gain name="/systems/electrical/sources/tr-1/output-volt"> <input>/systems/electrical/bus/ac-1</input> <!-- TODO: via 2PU1 CB --> <gain>0.24347826086956523</gain> <!-- AC to DC converter --> </pure_gain> <fcs_function name="/systems/electrical/sources/tr-1/output-amp"> <!-- TODO: make it depend on current draw --> <function> <table> <independentVar lookup="row">/systems/electrical/sources/tr-1/output-volt</independentVar> <tableData> 0 0 27.5 200 </tableData> </table> </function> </fcs_function> <pure_gain name="/systems/electrical/sources/tr-2/output-volt"> <input>/systems/electrical/bus/ac-2</input> <!-- TODO: via 2PU2 CB --> <gain>0.24347826086956523</gain> <!-- AC to DC converter --> </pure_gain> <fcs_function name="/systems/electrical/sources/tr-2/output-amp"> <!-- TODO: make it depend on current draw --> <function> <table> <independentVar lookup="row">/systems/electrical/sources/tr-2/output-volt</independentVar> <tableData> 0 0 27.5 200 </tableData> </table> </function> </fcs_function> <switch name="/systems/electrical/sources/ess-tr/working"> <default value="0"/> <test value="0.24347826086956523"> /systems/failures/electrical/ess-tr eq 0 </test> </switch> <pure_gain name="/systems/electrical/sources/ess-tr/output-volt"> <input>/systems/electrical/bus/ac-ess</input> <!-- TODO: via 2PU1 CB --> <gain>/systems/electrical/sources/ess-tr/working</gain> <!-- AC to DC converter --> </pure_gain> <fcs_function name="/systems/electrical/sources/ess-tr/output-amp"> <!-- TODO: make it depend on current draw --> <function> <table> <independentVar lookup="row">/systems/electrical/sources/ess-tr/output-volt</independentVar> <tableData> 0 0 27.5 200 </tableData> </table> </function> </fcs_function> <!-- Transformer Rectifier Contactors (Relays) --> <switch name="/systems/electrical/relay/tr-contactor-1/contact-pos"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/sources/tr-1/output-volt ne 0 /systems/electrical/sources/tr-1/output-amp ne 0 /systems/failures/electrical/tr-1 eq 0 </test> </switch> <switch name="/systems/electrical/relay/tr-contactor-1/output"> <default value="0"/> <test value="/systems/electrical/sources/tr-1/output-volt"> /systems/electrical/relay/tr-contactor-1/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/tr-contactor-1/output-amp"> <default value="0"/> <test value="/systems/electrical/sources/tr-1/output-amp"> /systems/electrical/relay/tr-contactor-1/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/tr-contactor-2/contact-pos"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/sources/tr-2/output-volt ne 0 /systems/electrical/sources/tr-2/output-amp ne 0 /systems/failures/electrical/tr-2 eq 0 </test> </switch> <switch name="/systems/electrical/relay/tr-contactor-2/output"> <default value="0"/> <test value="/systems/electrical/sources/tr-2/output-volt"> /systems/electrical/relay/tr-contactor-2/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/tr-contactor-2/output-amp"> <default value="0"/> <test value="/systems/electrical/sources/tr-2/output-amp"> /systems/electrical/relay/tr-contactor-2/contact-pos eq 1 </test> </switch> <!-- DC Bus Tie Relays --> <switch name="/systems/electrical/relay/dc-bus-tie-dc-1/contact-pos"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/bus/ac-1 ge 110 /systems/electrical/bus/dc-1 ge 25 /systems/electrical/relay/tr-contactor-1/contact-pos eq 1 </test> <test logic="AND" value="1"> /systems/electrical/bus/dc-bat ge 25 /systems/electrical/bus/dc-bat-src ne 3 <test logic="OR"> /systems/electrical/relay/tr-contactor-1/contact-pos eq 0 /systems/electrical/relay/tr-contactor-2/contact-pos eq 0 </test> </test> </switch> <switch name="/systems/electrical/relay/dc-bus-tie-dc-1/output"> <default value="0"/> <test logic="AND" value="/systems/electrical/bus/dc-bat"> /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/dc-bus-tie-dc-2/contact-pos"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/relay/dc-ess-feed-bat/contact-pos eq 0 /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 0 /systems/electrical/relay/tr-contactor-2/contact-pos eq 1 /systems/electrical/bus/dc-2 ge 25 </test> <test logic="AND" value="1"> /systems/electrical/bus/dc-bat ge 25 /systems/electrical/bus/dc-bat-src ne 3 <test logic="OR"> /systems/electrical/relay/tr-contactor-1/contact-pos eq 0 /systems/electrical/relay/tr-contactor-2/contact-pos eq 0 </test> </test> </switch> <switch name="/systems/electrical/relay/dc-bus-tie-dc-2/output"> <default value="0"/> <test logic="AND" value="/systems/electrical/bus/dc-bat"> /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1 </test> </switch> <!-- DC ESS Relays --> <switch name="/systems/electrical/relay/dc-ess-feed-tr/contact-pos"> <!-- TODO: supply via 4PE CB on 106VU, contactor via 5PE on 106VU --> <default value="0"/> <test logic="AND" value="1"> <test logic="OR"> /systems/electrical/relay/tr-contactor-1/output lt 25 /systems/electrical/relay/tr-contactor-2/output lt 25 /systems/electrical/relay/emer-glc/output ge 110 </test> /systems/electrical/sources/ess-tr/output-volt ge 25 </test> </switch> <switch name="/systems/electrical/relay/dc-ess-feed-tr/output"> <default value="0"/> <test value="/systems/electrical/sources/ess-tr/output-volt"> /systems/electrical/relay/dc-ess-feed-tr/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/dc-ess-feed-tr/output-amp"> <default value="0"/> <test value="/systems/electrical/sources/ess-tr/output-amp"> /systems/electrical/relay/dc-ess-feed-tr/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/dc-ess-feed-bat/contact-pos"> <!-- TODO: via 20PC1 80A fuse on 120VU --> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/relay/dc-ess-feed-tr/contact-pos eq 0 <test logic="OR"> /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 0 /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 0 </test> /controls/electrical/switches/emer-gen-test eq 0 </test> </switch> <switch name="/systems/electrical/relay/dc-ess-feed-bat/output"> <default value="0"/> <test value="/systems/electrical/bus/dc-bat"> /systems/electrical/relay/dc-ess-feed-bat/contact-pos eq 1 </test> </switch> <!-- DC Ess Shedding --> <switch name="/systems/electrical/relay/dc-ess-shed-switch/contact-pos"> <default value="1"/> <test logic="OR" value="0"> <!-- TODO: confirm these conditions are for galley, NOT ESS --> /systems/electrical/sources/si-1/inverter-active eq 1 /controls/electrical/switches/emer-gen-test eq 1 </test> </switch> <!-- DC Service Bus --> <switch name="/systems/electrical/relay/dc-svc-bus-contactor-tr/contact-pos"> <!-- TODO: via 1PX CB on 124VU --> <default value="0"/> </switch> <switch name="/systems/electrical/relay/dc-svc-bus-contactor-tr/output"> <default value="0"/> <test value="/systems/electrical/relay/tr-contactor-2/output"> /systems/electrical/relay/dc-svc-bus-contactor-tr/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/dc-svc-bus-contactor-bus-2/contact-pos"> <!-- TODO: via 7PN CB on 124VU --> <default value="1"/> </switch> <switch name="/systems/electrical/relay/dc-svc-bus-contactor-bus-2/output"> <default value="0"/> <test value="/systems/electrical/bus/dc-2"> /systems/electrical/relay/dc-svc-bus-contactor-bus-2/contact-pos eq 1 </test> </switch> <!-- DC Bus 1 --> <switch name="/systems/electrical/bus/dc-1-src"> <description>Tell which source is being used for priority purpose</description> <default value="0"/> <!-- OFF --> <test value="1"> <!-- TR1 --> /systems/electrical/relay/tr-contactor-1/output ge 25 </test> <test value="2"> <!-- DC BAT --> /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1 </test> </switch> <fcs_function name="/systems/electrical/bus/dc-1"> <function> <ifthen> <eq> <property>/systems/failures/electrical/dc-1-bus</property> <value>1</value> </eq> <value>0</value> <max> <property>/systems/electrical/relay/tr-contactor-1/output</property> <property>/systems/electrical/relay/dc-bus-tie-dc-1/output</property> </max> </ifthen> </function> </fcs_function> <!-- DC Bus 2 --> <switch name="/systems/electrical/bus/dc-2-src"> <description>Tell which source is being used for priority purpose</description> <default value="0"/> <!-- OFF --> <test value="1"> <!-- TR1 --> /systems/electrical/relay/tr-contactor-2/output ge 25 </test> <test value="2"> <!-- DC BAT --> /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1 </test> </switch> <fcs_function name="/systems/electrical/bus/dc-2"> <function> <ifthen> <eq> <property>/systems/failures/electrical/dc-2-bus</property> <value>1</value> </eq> <value>0</value> <max> <property>/systems/electrical/relay/tr-contactor-2/output</property> <property>/systems/electrical/relay/dc-bus-tie-dc-2/output</property> </max> </ifthen> </function> </fcs_function> <fcs_function name="/systems/electrical/bus/dc-service-bus"> <function> <max> <property>/systems/electrical/relay/dc-svc-bus-contactor-tr/output</property> <property>/systems/electrical/relay/dc-svc-bus-contactor-bus-2/output</property> </max> </function> </fcs_function> <!-- DC Bus Tie DC Bus Relays (continued) --> <!-- These outputs are from the DC Bus to the DC Bus Tie --> <switch name="/systems/electrical/relay/dc-bus-tie-dc-1/output-tie"> <default value="0"/> <test value="/systems/electrical/bus/dc-1"> /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1 </test> </switch> <switch name="/systems/electrical/relay/dc-bus-tie-dc-2/output-tie"> <default value="0"/> <test value="/systems/electrical/bus/dc-2"> /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1 </test> </switch> <!-- DC Bat Bus --> <switch name="/systems/electrical/bus/dc-bat-src"> <description>Tell which source is being used for priority purpose</description> <default value="0"/> <!-- OFF --> <test value="1"> <!-- DC1 --> /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1 /systems/electrical/bus/dc-1-src ne 2 </test> <test value="2"> <!-- DC2 --> /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1 /systems/electrical/bus/dc-2-src ne 2 </test> <test logic="OR" value="3"> <!-- BAT --> <test logic="AND"> /instrumentation/airspeed-indicator/indicated-speed-kt lt 100 <test logic="OR"> /controls/electrical/switches/bat-1 eq 1 /controls/electrical/switches/bat-2 eq 1 </test> /systems/electrical/some-electric-thingie/emer-elec-config eq 1 </test> <test logic="AND"> <test logic="OR"> /controls/electrical/switches/bat-1 eq 1 /controls/electrical/switches/bat-2 eq 1 </test> /systems/apu/dc-bat-three-minutes eq 1 </test> </test> </switch> <switch name="/systems/electrical/bus/dc-bat"> <default value="0"/> <test value="0"> /systems/failures/electrical/dc-bat-bus eq 1 </test> <test logic="AND" value="/systems/electrical/relay/dc-bus-tie-dc-1/output-tie"> /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1 /systems/electrical/bus/dc-1-src ne 2 </test> <test logic="AND" value="/systems/electrical/relay/dc-bus-tie-dc-2/output-tie"> /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 1 /systems/electrical/bus/dc-2-src ne 2 </test> <test logic="OR" value="/systems/electrical/sources/bat-1/volt"> <test logic="AND"> /instrumentation/airspeed-indicator/indicated-speed-kt lt 100 /controls/electrical/switches/bat-1 eq 1 /systems/electrical/bus/dc-bat-src eq 3 /systems/electrical/sources/bat-1/volt ge 25 /systems/electrical/some-electric-thingie/emer-elec-config eq 1 </test> <test logic="AND"> /systems/apu/dc-bat-three-minutes eq 1 /controls/electrical/switches/bat-1 eq 1 /systems/electrical/bus/dc-bat-src eq 3 /systems/electrical/sources/bat-1/volt ge 25 </test> </test> <test logic="OR" value="/systems/electrical/sources/bat-2/volt"> <test logic="AND"> /instrumentation/airspeed-indicator/indicated-speed-kt lt 100 /controls/electrical/switches/bat-2 eq 1 /systems/electrical/bus/dc-bat-src eq 3 /systems/electrical/sources/bat-2/volt ge 25 /systems/electrical/some-electric-thingie/emer-elec-config eq 1 </test> <test logic="AND"> /systems/apu/dc-bat-three-minutes eq 1 /controls/electrical/switches/bat-2 eq 1 /systems/electrical/bus/dc-bat-src eq 3 /systems/electrical/sources/bat-2/volt ge 25 </test> </test> </switch> <!-- DC ESS Bus --> <fcs_function name="/systems/electrical/bus/dc-ess"> <function> <ifthen> <eq> <property>/systems/failures/electrical/dc-ess-bus</property> <value>1</value> </eq> <value>0</value> <max> <property>/systems/electrical/relay/dc-ess-feed-bat/output</property> <property>/systems/electrical/relay/dc-ess-feed-tr/output</property> </max> </ifthen> </function> </fcs_function> <pure_gain name="/systems/electrical/bus/dc-ess-shed"> <input>/systems/electrical/bus/dc-ess</input> <gain>/systems/electrical/relay/dc-ess-shed-switch/contact-pos</gain> </pure_gain> <!-- Hot Buses --> <pure_gain name="/systems/electrical/bus/dc-hot-1"> <input>/systems/electrical/sources/bat-1/volt</input> <!-- todo CB 12PB1 / 5PB1 --> <gain>1.0</gain> </pure_gain> <pure_gain name="/systems/electrical/bus/dc-hot-2"> <input>/systems/electrical/sources/bat-2/volt</input> <!-- todo CB 12PB2 / 5PB2 --> <gain>1.0</gain> </pure_gain> <switch name="/systems/electrical/some-electric-thingie/emer-elec-config"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/bus/ac-1 lt 110 /systems/electrical/bus/ac-2 lt 110 </test> <test logic="AND" value="1"> /systems/electrical/relay/ext-epc/contact-pos eq 0 <test logic="OR"> /controls/electrical/switches/gen-1 eq 0 /systems/failures/electrical/gen-1 eq 1 </test> <test logic="OR"> /controls/electrical/switches/gen-2 eq 0 /systems/failures/electrical/gen-2 eq 1 </test> <test logic="OR"> /controls/electrical/switches/apu eq 0 /systems/failures/electrical/apu eq 1 /engines/engine[2]/n1 lt 94.9 </test> </test> </switch> <switch name="/systems/electrical/some-electric-thingie/emer-elec-config-generator-1-bustie"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /systems/electrical/some-electric-thingie/generator-1-pb eq 1 /controls/electrical/switches/bus-tie eq 0 </test> </switch> <switch name="/systems/electrical/some-electric-thingie/emer-elec-config-generator-2-bustie"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /systems/electrical/some-electric-thingie/generator-2-pb eq 1 /controls/electrical/switches/bus-tie eq 0 </test> </switch> <switch name="/systems/electrical/some-electric-thingie/emer-elec-config-generator-1"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /systems/electrical/some-electric-thingie/generator-1-pb eq 1 </test> </switch> <switch name="/systems/electrical/some-electric-thingie/emer-elec-config-generator-2"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/some-electric-thingie/emer-elec-config eq 1 /systems/electrical/some-electric-thingie/generator-2-pb eq 1 </test> </switch> <actuator name="/systems/electrical/some-electric-thingie/static-inverter-timer"> <input>/systems/electrical/relay/ac-ess-feed-inverter/contact-pos</input> <rate_limit sense="decr">120</rate_limit> <!-- Instant --> <rate_limit sense="incr">0.1</rate_limit> <!-- 10 seconds --> </actuator> <!-- Output to Generics to keep FG things working, temporary, until we know what gets power by what bus --> <switch name="/systems/electrical/generic-pwr"> <description>This makes the FG stuff work because we killed the generic electrical</description> <default value="0"/> <test value="/systems/electrical/bus/dc-1"> /systems/electrical/bus/dc-1 ge 25 </test> <test value="/systems/electrical/bus/dc-2"> /systems/electrical/bus/dc-2 ge 25 </test> <!--<output>/systems/electrical/outputs/adf</output> <output>/systems/electrical/outputs/dme</output>--> <output>/systems/electrical/outputs/efis</output> <output>/systems/electrical/outputs/fcp-power</output> <output>/systems/electrical/outputs/fuel-pump[0]</output> <output>/systems/electrical/outputs/fuel-pump[1]</output> <output>/systems/electrical/outputs/fuel-pump[2]</output> <output>/systems/electrical/outputs/gps</output> <output>/systems/electrical/outputs/mk-viii</output> <!--<output>/systems/electrical/outputs/nav[0]</output> <output>/systems/electrical/outputs/nav[1]</output> <output>/systems/electrical/outputs/nav[2]</output> <output>/systems/electrical/outputs/nav[3]</output>--> <output>/systems/electrical/outputs/tacan</output> <output>/systems/electrical/outputs/turn-coordinator</output> </switch> </channel> <!-- Notes --> <!-- Priority: eng, ext, apu but EXT ON lt stays on even when not feeding a/c --> <!-- TR 2 fail leads to loss of gnd FLT bus --> <channel name="Overhead Lights" execrate="8"> <switch name="/systems/electrical/light/ac-ess-feed-fault"> <default value="0"/> <test value="1"> /systems/electrical/bus/ac-ess lt 110 </test> </switch> <switch name="/systems/electrical/light/apu-fault"> <default value="0"/> <test logic="AND" value="1"> /controls/electrical/switches/apu eq 1 <test logic="OR"> /systems/electrical/sources/apu/gcu-fault eq 1 <test logic="AND"> /systems/electrical/relay/apu-glc/contact-pos eq 0 /systems/electrical/relay/ext-epc/contact-pos eq 0 /systems/electrical/relay/gen-1-glc/contact-pos eq 0 /systems/electrical/relay/gen-2-glc/contact-pos eq 0 </test> </test> /systems/electrical/sources/apu/drive-rpm gt 22800 </test> </switch> <switch name="/systems/electrical/light/bat-1-fault"> <default value="0"/> <test value="1"> <!-- TODO: depends charging current --> /systems/failures/electrical/bat-1 eq 1 </test> </switch> <switch name="/systems/electrical/light/bat-2-fault"> <default value="0"/> <test value="1"> <!-- TODO: depends charging current --> /systems/failures/electrical/bat-2 eq 1 </test> </switch> <!-- TODO: galley fault when load > 100 --> <switch name="/systems/electrical/light/galley-fault"> <default value="0"/> </switch> <switch name="/systems/electrical/light/gen-1-fault"> <default value="0"/> <test value="1"> /controls/electrical/switches/gen-1 eq 1 <test logic="OR"> /systems/electrical/sources/idg-1/gcu-1-fault eq 1 /systems/electrical/relay/gen-1-glc/contact-pos eq 0 </test> </test> </switch> <switch name="/systems/electrical/light/gen-2-fault"> <default value="0"/> <test value="1"> /controls/electrical/switches/gen-2 eq 1 <test logic="OR"> /systems/electrical/sources/idg-2/gcu-2-fault eq 1 /systems/electrical/relay/gen-2-glc/contact-pos eq 0 </test> </test> </switch> <switch name="/systems/electrical/light/idg-1-fault"> <default value="0"/> <test logic="AND" value="1"> /systems/failures/electrical/idg-1 eq 1 /systems/electrical/sources/idg-1/drive-rpm gt 2000 </test> <test logic="AND" value="1"> /controls/electrical/switches/idg-1-disc-momentary eq 1 </test> </switch> <switch name="/systems/electrical/light/idg-2-fault"> <default value="0"/> <test logic="AND" value="1"> /systems/failures/electrical/idg-2 eq 1 /systems/electrical/sources/idg-2/drive-rpm gt 2000 </test> <test logic="AND" value="1"> /controls/electrical/switches/idg-2-disc-momentary eq 1 </test> </switch> <switch name="/systems/electrical/light/rat-emer-gen-fault"> <default value="0"/> <test logic="AND" value="1"> /systems/electrical/relay/dc-ess-feed-tr/output eq 0 /systems/electrical/bus/ac-1 eq 0 /systems/electrical/bus/ac-2 eq 0 position/wow eq 0 </test> </switch> </channel> </system>