/systems/oxygen/cockpit-oxygen/cockpit-bottle-L
/systems/oxygen/cockpit-oxygen/distributor-manifold-L
/controls/oxygen/cockpit-oxygen-supply-pb eq 1
/systems/electrical/bus/dc-ess-shed ge 25
/systems/oxygen/cockpit-oxygen/supply-valve-cmd
10
/systems/oxygen/cockpit-oxygen/distributor-manifold-L
15
/controls/oxygen/cockpit-mask-1-on
/systems/pressurization/cabinalt
/controls/oxygen/cockpit-mask-1-selector
0 1
0 0 29.5
5000 0.0 31.0
8000 0.17 36.4
10000 0.71 36.9
15000 5.60 37.9
20000 15.9 38.9
30000 30.4 39.9
35000 40.9 40.9
40000 41.9 41.9
/systems/oxygen/cockpit-oxygen/distributor-manifold-L
15
/controls/oxygen/cockpit-mask-2-on
/systems/pressurization/cabinalt
/controls/oxygen/cockpit-mask-2-selector
0 1
0 0 29.5
5000 0.0 31.0
8000 0.17 36.4
10000 0.71 36.9
15000 5.60 37.9
20000 15.9 38.9
30000 30.4 39.9
35000 40.9 40.9
40000 41.9 41.9
/systems/oxygen/cockpit-oxygen/distributor-manifold-L
15
/controls/oxygen/cockpit-mask-3-on
/systems/pressurization/cabinalt
/controls/oxygen/cockpit-mask-3-selector
0 1
0 0 29.5
5000 0.0 31.0
8000 0.17 36.4
10000 0.71 36.9
15000 5.60 37.9
20000 15.9 38.9
30000 30.4 39.9
35000 40.9 40.9
40000 41.9 41.9
/systems/oxygen/cockpit-oxygen/distributor-manifold-L
15
/controls/oxygen/cockpit-mask-4-on
/systems/pressurization/cabinalt
/controls/oxygen/cockpit-mask-4-selector
0 1
0 0 29.5
5000 0.0 31.0
8000 0.17 36.4
10000 0.71 36.9
15000 5.60 37.9
20000 15.9 38.9
30000 30.4 39.9
35000 40.9 40.9
40000 41.9 41.9
/systems/oxygen/cockpit-oxygen/cockpit-bottle-L
-/systems/oxygen/cockpit-oxygen/hp-regulator-flow-rate
60
simulation/channel-dt
0.0
2183.0
58.58145
/systems/oxygen/cockpit-oxygen/cockpit-bottle-L
0.4512568
/systems/oxygen/cockpit-oxygen/cockpit-bottle-L
0 0
500 200
1000 275
2000 300
2183 300
/systems/oxygen/cockpit-oxygen/supply-valve
/systems/oxygen/cockpit-oxygen/distributor-manifold-L
0 300
14.5 170
15 0
/systems/oxygen/cockpit-oxygen/bottle-flow-rate
/systems/oxygen/cockpit-oxygen/supply-valve
/systems/oxygen/cockpit-oxygen/mask-1-flow-rate
/systems/oxygen/cockpit-oxygen/mask-2-flow-rate
/systems/oxygen/cockpit-oxygen/mask-3-flow-rate
/systems/oxygen/cockpit-oxygen/mask-4-flow-rate
/systems/oxygen/cockpit-oxygen/distributor-fill-rate
0.0
/systems/oxygen/cockpit-oxygen/hp-regulator-flow-rate-calc
-/systems/oxygen/cockpit-oxygen/mask-1-flow-rate
-/systems/oxygen/cockpit-oxygen/mask-2-flow-rate
-/systems/oxygen/cockpit-oxygen/mask-3-flow-rate
-/systems/oxygen/cockpit-oxygen/mask-4-flow-rate
/systems/oxygen/cockpit-oxygen/hp-regulator-flow-rate
/systems/oxygen/cockpit-oxygen/distributor-manifold-L
/systems/oxygen/cockpit-oxygen/distributor-manifold-rate
60
simulation/channel-dt
0.0
15.0
75
/systems/oxygen/cockpit-oxygen/distributor-manifold-L
1
/systems/oxygen/cockpit-oxygen/distributor-psi lt 50
/systems/pressurization/cabinalt ge 14000
/systems/electrical/bus/dc-ess ge 25
/systems/oxygen/passenger-oxygen/pressure-switch eq 1
/controls/oxygen/passenger-mask-deploy-man eq 1
/systems/oxygen/passenger-oxygen/masks-deploy-cmd eq 1
/systems/electrical/bus/ac-ess-shed ge 110
/controls/oxygen/passenger-mask-reset eq 1
/systems/electrical/bus/dc-ess-shed lt 25
/systems/oxygen/passenger-oxygen/masks-deploy-cmd eq 1
/systems/electrical/bus/dc-ess-shed ge 25