legoboyvdlp R
177679ff7a
EMER ELEC: big fixes to the logic of the warning
2021-01-31 17:24:49 +00:00
legoboyvdlp R
0061859467
Acconfig unlatch the GCU fault. This stops you possibly losing power in acconfig
2020-10-20 22:29:21 +01:00
legoboyvdlp R
62ab5483f0
Bugfix for yaw damper fault on startup
2020-10-20 22:24:29 +01:00
legoboyvdlp R
9bb2ec1522
Fix that DC ESS SHED is powered when it shouldn't
2020-10-19 21:45:08 +01:00
legoboyvdlp R
68593890bf
Add auto-switching for the AC ESS after three seconds; also correct switch control power to ac1 / ac2
2020-10-14 15:32:58 +01:00
legoboyvdlp R
aed192c7ae
Same thing for APU
2020-10-14 15:13:24 +01:00
legoboyvdlp R
6a8f13aeb4
Emergency bugfix: fix that GCU fault would inhibit gens connecting on startup...
2020-10-14 13:51:30 +01:00
legoboyvdlp R
117f0256f8
Electrical: GCU should be powered by PMG or by DC BAT bus. Therefore, you can control with GEN pb sw if you have PMG volts _or_ if you have DC BAT. Also, disc power is on DC BAT, not DC ESS, even though indication is on ESS. Typically weird Airbus
2020-10-14 00:32:24 +01:00
legoboyvdlp R
59c092a5bd
IDG improvements:
...
1) restrict disconnection with underspeed condition (14%)
2) Fire pushbutton should deactivate, not disconnect IDG. Therefore, it opens the GCR rather than setting input rpm to zero.
3) Generator comes online at 52% N2 (4730 RPM)
4) Wider range of acceptable frequencies per AMM
5) Gen faults latch -- allows for potential restoration upon reset of the generator switch
6) CSD: restrict rpm range between 4500 -- 9120 rpm
2020-10-13 23:53:15 +01:00
legoboyvdlp R
473b85d106
Fix pushbutton sound volume; fix lower ecam typo. Prepare to add static inverter fault
2020-10-13 21:45:48 +01:00
legoboyvdlp R
a443e0aa83
Fix battery percent
2020-08-13 19:54:58 +01:00
legoboyvdlp R
a57235c3df
Correction to electrical power on batteries only on the ground
2020-07-26 17:56:09 +01:00
legoboyvdlp R
b9812c92c4
ELEC ECAM page: fix galley indications
2020-05-22 22:04:31 +01:00
legoboyvdlp R
443207e9b6
Make the batteries drain when static inverter is active
2020-05-03 17:24:03 +01:00
legoboyvdlp R
d6344cca6e
New battery charging logic
2020-05-03 17:13:49 +01:00
legoboyvdlp R
8bf1035d0d
Acconfig...
2020-04-18 00:51:16 +01:00
legoboyvdlp R
d0d6c8fa82
Fix ref to old prop, remove old apu system, acconfig
2020-04-17 23:41:36 +01:00
legoboyvdlp R
b7fd20b692
JSBSim apu
2020-04-17 17:07:04 +01:00
legoboyvdlp R
e18c7fc04e
Potential fix for RAT popping out when it shouldn't
2020-03-21 13:54:05 +00:00
legoboyvdlp R
78fc93c313
Fix APU FAULT light
2020-01-02 22:11:02 +00:00
legoboyvdlp R
b61b45abde
Bugfixes, new CLR function, fix FBW -> autopilot failures, etc
2020-01-02 21:13:18 +00:00
legoboyvdlp R
928144a072
Bugfix FCU, RAT MAN light, and ECAM autopilot message
2020-01-01 21:30:13 +00:00
legoboyvdlp R
d9903d85a6
Fix SEC power source, fix RAT getting retracted, fix other stuff
2019-12-28 20:56:03 +00:00
legoboyvdlp R
884890c927
ECAM: fix the EMER ELEC message, move autothrust warnings to correct priority
2019-12-28 17:35:46 +00:00
legoboyvdlp R
b1bfb39c4a
Radar altimeter, ADR / IR panel hooked up
2019-11-04 19:20:56 +00:00
legoboyvdlp R
f8f87ed042
Many bugfixes
2019-10-31 18:57:19 +00:00
legoboyvdlp R
8e16512dfb
Electrical: fix bug with the static inverter
2019-10-24 17:09:32 +01:00
legoboyvdlp R
040c72ccb6
Bugfix electrical system
2019-10-19 13:37:16 +01:00
legoboyvdlp R
d78336a855
Electrical: failures, generic outputs, fix logic
2019-10-17 20:40:13 +01:00
legoboyvdlp R
2bccaf9e54
Fix references to ac1 / ac2 bus
2019-10-16 19:33:44 +01:00
legoboyvdlp R
15864edff8
Fix failures in the electrical system - generator / TR failure handled now
2019-10-16 19:18:50 +01:00
legoboyvdlp R
2d37be9a2f
Electrical: fix DC BAT
2019-10-15 20:24:51 +01:00
legoboyvdlp R
5046369761
Hydraulics: correct PTU function, fire valves
2019-10-15 19:03:43 +01:00
legoboyvdlp R
6555d85c08
Add hydraulic system; bugfix IESI, fixes for the ECAM
2019-10-15 16:50:09 +01:00
Josh Davidson
3ce57e9476
A320-family fork
2019-10-14 12:48:35 -04:00