1
0
Fork 0

A320: transfer valves only open if the FQI is powered too

This commit is contained in:
legoboyvdlp R 2019-11-11 19:07:01 +00:00
parent a89f2e00d9
commit c9ba4a27ed

View file

@ -194,6 +194,7 @@
/systems/fuel/refuel/refuelling eq 0
</test>
<test logic="AND" value="1">
/systems/fuel/valves/outer-inner-transfer-valve-1-power eq 1
<test logic="OR">
/systems/fuel/quantity/left-wing-inner-low eq 1
/systems/fuel/quantity/right-wing-inner-low eq 1
@ -204,8 +205,9 @@
<switch name="/systems/fuel/valves/outer-inner-transfer-valve-1-power">
<default value="0"/>
<test value="0.333">
<test logic="OR" value="0.333">
/systems/electrical/bus/dc-ess-shed ge 25
/systems/electrical/bus/dc-2 ge 25
</test>
</switch>
@ -221,6 +223,7 @@
/systems/fuel/refuel/refuelling eq 0
</test>
<test logic="AND" value="1">
/systems/fuel/valves/outer-inner-transfer-valve-2-power eq 1
<test logic="OR">
/systems/fuel/quantity/left-wing-inner-low eq 1
/systems/fuel/quantity/right-wing-inner-low eq 1
@ -231,8 +234,9 @@
<switch name="/systems/fuel/valves/outer-inner-transfer-valve-2-power">
<default value="0"/>
<test value="0.333">
<test logic="OR" value="0.333">
/systems/electrical/bus/dc-ess-shed ge 25
/systems/electrical/bus/dc-2 ge 25
</test>
</switch>
@ -623,7 +627,7 @@
/systems/fuel/valves/outer-inner-transfer-valve-1 eq 1
/accelerations/pilot-gdamped ge 0.5
/consumables/fuel/tank[0]/level-gal_us gt /consumables/fuel/tank[0]/unusable-gal_us
/consumables/fuel/tank[1]/level-norm lt 0.999
/consumables/fuel/tank[1]/level-norm lt 0.9999
</test>
</switch>
@ -633,7 +637,7 @@
/systems/fuel/valves/outer-inner-transfer-valve-2 eq 1
/accelerations/pilot-gdamped ge 0.5
/consumables/fuel/tank[4]/level-gal_us gt /consumables/fuel/tank[4]/unusable-gal_us
/consumables/fuel/tank[3]/level-norm lt 0.999
/consumables/fuel/tank[3]/level-norm lt 0.9999
</test>
</switch>