Fix that engines wouldn't shutdown when LP valves are commanded closed
This commit is contained in:
parent
701e52198e
commit
c175461ea4
1 changed files with 27 additions and 1 deletions
|
@ -542,6 +542,32 @@
|
|||
</test>
|
||||
</switch>
|
||||
|
||||
<switch name="rubbish/pipes-unusable-volume-1">
|
||||
<default value="0"/>
|
||||
<test logic="AND" value="1.5">
|
||||
/systems/acconfig/autoconfig-running eq 0
|
||||
/systems/fuel/valves/engine-1-lp-valve eq 0
|
||||
</test>
|
||||
<output>propulsion/tank[5]/unusable-volume-gal</output>
|
||||
</switch>
|
||||
|
||||
<switch name="rubbish/pipes-unusable-volume-2">
|
||||
<default value="0"/>
|
||||
<test logic="AND" value="1.5">
|
||||
/systems/acconfig/autoconfig-running eq 0
|
||||
/systems/fuel/valves/engine-2-lp-valve eq 0
|
||||
</test>
|
||||
<output>propulsion/tank[6]/unusable-volume-gal</output>
|
||||
</switch>
|
||||
|
||||
<switch name="rubbish/pipes-unusable-volume-apu">
|
||||
<default value="0"/>
|
||||
<test logic="AND" value="1.5">
|
||||
/systems/acconfig/autoconfig-running eq 0
|
||||
/systems/fuel/valves/apu-lp-valve eq 0
|
||||
</test>
|
||||
<output>propulsion/tank[7]/unusable-volume-gal</output>
|
||||
</switch>
|
||||
<!-- Feed system -->
|
||||
|
||||
<switch name="/systems/fuel/internal/apu-source"> <!-- this only when all pumps off -->
|
||||
|
@ -773,7 +799,7 @@
|
|||
<summer name="/systems/fuel/internal/eng-1-flow-rate">
|
||||
<input>/systems/fuel/internal/left-wing-tank-eng-1</input>
|
||||
<input>/systems/fuel/internal/right-wing-tank-eng-1</input>
|
||||
<input>/systems/fuel/internal/center-tank-eng-2</input>
|
||||
<input>/systems/fuel/internal/center-tank-eng-1</input>
|
||||
<output>propulsion/tank[5]/external-flow-rate-pps</output>
|
||||
</summer>
|
||||
|
||||
|
|
Loading…
Reference in a new issue