1
0
Fork 0

Same thing for APU

This commit is contained in:
legoboyvdlp R 2020-10-14 15:08:29 +01:00
parent 6a8f13aeb4
commit aed192c7ae
2 changed files with 74 additions and 29 deletions

View file

@ -3338,10 +3338,7 @@
<repeatable>false</repeatable>
<binding>
<condition>
<greater-than-equals>
<property>systems/electrical/bus/dc-bat</property>
<value>25</value>
</greater-than-equals> <!-- control is on DC BAT bus 301PP via 11 PB - so if you enter EMER ELEC with it turned off, too bad -->
<property>/systems/electrical/sources/apu/gcu-powered</property>
</condition>
<command>property-toggle</command>
<property>controls/electrical/switches/apu</property>

View file

@ -525,27 +525,15 @@
</pure_gain>
<!-- APU gen -->
<pure_gain name="/systems/electrical/sources/apu/drive-rpm-input">
<pure_gain name="/systems/electrical/sources/apu/drive-rpm">
<input>/engines/engine[2]/n1</input>
<gain>240.34</gain>
</pure_gain>
<switch name="/systems/electrical/sources/apu/working">
<default value="1"/>
<test logic="OR" value="0">
/controls/apu/fire-btn eq 1
</test>
</switch>
<pure_gain name="/systems/electrical/sources/apu/drive-rpm">
<input>/systems/electrical/sources/apu/drive-rpm-input</input>
<gain>/systems/electrical/sources/apu/working</gain>
</pure_gain>
<fcs_function name="/systems/electrical/sources/apu/pmg-volt">
<function>
<product>
<property>/systems/electrical/sources/apu/drive-rpm-input</property>
<property>/systems/electrical/sources/apu/drive-rpm</property>
<quotient>
<value>115</value>
<value>24000</value>
@ -558,7 +546,7 @@
<function>
<quotient>
<product>
<property>/systems/electrical/sources/apu/drive-rpm-input</property>
<property>/systems/electrical/sources/apu/drive-rpm</property>
<value>2</value> <!-- Number of poles in generator -->
</product>
<value>120</value>
@ -569,9 +557,10 @@
<switch name="/systems/electrical/sources/apu/gcr-relay">
<default value="0"/>
<test logic="AND" value="1">
/controls/apu/fire-btn ne 1
/controls/electrical/switches/apu eq 1
/systems/failures/electrical/apu ne 1
/systems/electrical/sources/apu/drive-rpm-input ge 23000
/systems/electrical/sources/apu/drive-rpm ge 22800
</test>
</switch>
@ -934,16 +923,70 @@
</test>
</switch>
<switch name="/systems/electrical/sources/apu/gcu-powered">
<default value="0"/>
<test logic="OR" value="1">
/systems/electrical/bus/dc-bat ge 25
/systems/electrical/sources/apu/pmg-volt ge 101.5
</test>
</switch>
<switch name="/systems/electrical/sources/apu/gcu-voltage-trip">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/sources/apu/gcu-voltage-trip eq 1
/controls/electrical/switches/apu eq 1
</test>
<test logic="AND" value="1">
/systems/electrical/relay/apu-glc/contact-pos eq 1
<test logic="OR">
/systems/electrical/sources/apu/output-volt lt 101.5
/systems/electrical/sources/apu/output-volt gt 130
</test>
</test>
</switch>
<switch name="/systems/electrical/sources/apu/gcu-frequency-trip">
<default value="0"/>
<test logic="AND" value="1">
/systems/electrical/sources/apu/gcu-frequency-trip eq 1
/controls/electrical/switches/apu eq 1
</test>
<test logic="AND" value="1">
/systems/electrical/relay/apu-glc/contact-pos eq 1
<test logic="OR">
/systems/electrical/sources/apu/output-hertz lt 361
/systems/electrical/sources/apu/output-hertz gt 435
</test>
</test>
</switch>
<switch name="/systems/electrical/sources/apu/gcu-fault">
<default value="0"/>
<test logic="OR" value="0">
/systems/acconfig/autoconfig-running eq 1
/sim/time/elapsed-sec lt 10
</test>
<test logic="OR" value="1">
/systems/electrical/sources/apu/gcu-voltage-trip eq 1
/systems/electrical/sources/apu/gcu-frequency-trip eq 1
</test>
</switch>
<switch name="/systems/electrical/relay/apu-glc/contact-pos">
<default value="0"/>
<test logic="OR" value="0">
/sim/time/elapsed-sec lt 10
</test>
<test logic="AND" value="1">
/controls/apu/master eq 1
/controls/electrical/switches/apu eq 1
/systems/electrical/sources/apu/output-volt ge 110
/systems/electrical/sources/apu/output-volt lt 130
/systems/electrical/sources/apu/output-hertz ge 390
/systems/electrical/sources/apu/output-hertz le 410
/systems/electrical/sources/apu/output-volt ge 101.5
/systems/electrical/sources/apu/output-volt le 130
/systems/electrical/sources/apu/output-hertz ge 361
/systems/electrical/sources/apu/output-hertz le 435
/systems/electrical/relay/ext-epc/contact-pos eq 0
/systems/electrical/sources/apu/gcu-fault ne 1 <!-- software trip -->
</test>
</switch>
@ -1870,11 +1913,16 @@
<default value="0"/>
<test logic="AND" value="1">
/controls/electrical/switches/apu eq 1
<test logic="OR">
/systems/electrical/sources/apu/gcu-fault eq 1
<test logic="AND">
/systems/electrical/relay/apu-glc/contact-pos eq 0
/systems/electrical/relay/ext-epc/contact-pos eq 0
/systems/electrical/relay/gen-1-glc/contact-pos eq 0
/systems/electrical/relay/gen-2-glc/contact-pos eq 0
/systems/electrical/sources/apu/drive-rpm gt 2000
</test>
</test>
/systems/electrical/sources/apu/drive-rpm gt 22800
</test>
</switch>