From a57235c3df2dba32510789835f84e1e49358001a Mon Sep 17 00:00:00 2001 From: legoboyvdlp R Date: Sun, 26 Jul 2020 17:56:09 +0100 Subject: [PATCH] Correction to electrical power on batteries only on the ground --- Systems/a320-electrical.xml | 16 ++++++++-------- 1 file changed, 8 insertions(+), 8 deletions(-) diff --git a/Systems/a320-electrical.xml b/Systems/a320-electrical.xml index 5be2c780..ead9f997 100644 --- a/Systems/a320-electrical.xml +++ b/Systems/a320-electrical.xml @@ -686,7 +686,7 @@ /systems/electrical/bus/ac-2 ne 0 - /instrumentation/airspeed-indicator/indicated-speed-kt gt 100 + /instrumentation/airspeed-indicator/indicated-speed-kt ge 100 /systems/electrical/bus/ac-1 eq 0 /systems/electrical/bus/ac-2 eq 0 gear/unit[0]/WOW eq 0 @@ -1392,11 +1392,11 @@ /systems/electrical/relay/dc-ess-feed-tr/contact-pos eq 0 - /systems/electrical/relay/tr-contactor-1/contact-pos eq 1 - /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 1 - /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 0 + + /systems/electrical/relay/dc-bus-tie-dc-1/contact-pos eq 0 + /systems/electrical/relay/dc-bus-tie-dc-2/contact-pos eq 0 + /controls/electrical/switches/emer-gen-test eq 0 - /systems/electrical/bus/dc-1 ge 25 @@ -1541,7 +1541,7 @@ - /instrumentation/airspeed-indicator/indicated-speed-kt lt 50 + /instrumentation/airspeed-indicator/indicated-speed-kt lt 100 /controls/electrical/switches/bat-1 eq 1 /controls/electrical/switches/bat-2 eq 1 @@ -1573,7 +1573,7 @@ - /instrumentation/airspeed-indicator/indicated-speed-kt lt 50 + /instrumentation/airspeed-indicator/indicated-speed-kt lt 100 /controls/electrical/switches/bat-1 eq 1 /systems/electrical/bus/dc-bat-src eq 3 /systems/electrical/sources/bat-1/volt ge 25 @@ -1588,7 +1588,7 @@ - /instrumentation/airspeed-indicator/indicated-speed-kt lt 50 + /instrumentation/airspeed-indicator/indicated-speed-kt lt 100 /controls/electrical/switches/bat-2 eq 1 /systems/electrical/bus/dc-bat-src eq 3 /systems/electrical/sources/bat-2/volt ge 25