1
0
Fork 0

Fix that yellow elec pump would come on with yellow elec pump failed

This commit is contained in:
legoboyvdlp R 2020-10-18 17:42:36 +01:00
parent bcf4754174
commit 83e80c0a73

View file

@ -230,6 +230,7 @@
<default value="0"/>
<test logic="AND" value="1">
/controls/hydraulic/switches/yellow-elec eq 1
/systems/failures/hydraulic/yellow-elec ne 1
<test logic="OR"> <!-- TODO: via 3XX CB 122VU -->
/systems/electrical/sources/ext/output-volt ge 110
/systems/electrical/bus/ac-2 ge 110
@ -239,11 +240,6 @@
<fcs_function name="/systems/hydraulic/sources/yellow-elec/source-psi">
<function>
<ifthen>
<nq>
<property>/systems/failures/hydraulic/yellow-elec</property>
<value>1</value>
</nq>
<table>
<independentVar lookup="row">/systems/hydraulic/sources/yellow-elec/pump-operate</independentVar>
<tableData>
@ -251,8 +247,6 @@
1 3000
</tableData>
</table>
<value>0</value>
</ifthen>
</function>
</fcs_function>