APU: make the code shutting down the APU after 0.2 seconds of power loss more resilient, uisng JSBSim
This commit is contained in:
parent
5e61555eb5
commit
7dfd9f15ff
2 changed files with 161 additions and 145 deletions
|
@ -273,24 +273,6 @@ var APU = {
|
||||||
me.autoStop();
|
me.autoStop();
|
||||||
}
|
}
|
||||||
|
|
||||||
if (systems.ELEC.Bus.dcBat.getValue() < 25) {
|
|
||||||
if (!me._powerLost) {
|
|
||||||
me._powerLost = 1;
|
|
||||||
settimer(func() {
|
|
||||||
if (me._powerLost) {
|
|
||||||
if (me.GenericControls.starter.getValue()) {
|
|
||||||
me.GenericControls.starter.setValue(0);
|
|
||||||
}
|
|
||||||
if (me.state != 0) {
|
|
||||||
me.autoStop();
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}, 0.2);
|
|
||||||
}
|
|
||||||
} else {
|
|
||||||
me._powerLost = 0;
|
|
||||||
}
|
|
||||||
|
|
||||||
if (systems.ELEC.EmerElec.getValue() == 1 and (systems.ELEC.EmerElec45.getValue() != 1 and systems.ELEC.Source.EmerGen.voltsRelay.getValue() < 110)) {
|
if (systems.ELEC.EmerElec.getValue() == 1 and (systems.ELEC.EmerElec45.getValue() != 1 and systems.ELEC.Source.EmerGen.voltsRelay.getValue() < 110)) {
|
||||||
me.inhibitEMERELEC = 1;
|
me.inhibitEMERELEC = 1;
|
||||||
} else {
|
} else {
|
||||||
|
@ -316,6 +298,19 @@ var APUController = {
|
||||||
}
|
}
|
||||||
};
|
};
|
||||||
|
|
||||||
|
setlistener("/systems/apu/shutdown-power-loss", func(val) {
|
||||||
|
if (APUController.APU != nil) {
|
||||||
|
if (val.getBoolValue()) {
|
||||||
|
if (APUController.APU.GenericControls.starter.getValue()) {
|
||||||
|
APUController.APU.GenericControls.starter.setValue(0);
|
||||||
|
}
|
||||||
|
if (APUController.APU.state != 0) {
|
||||||
|
APUController.APU.autoStop();
|
||||||
|
}
|
||||||
|
}
|
||||||
|
}
|
||||||
|
}, 0, 0);
|
||||||
|
|
||||||
var _masterTime = 0;
|
var _masterTime = 0;
|
||||||
setlistener("/controls/apu/master", func() {
|
setlistener("/controls/apu/master", func() {
|
||||||
if (APUController.APU != nil) {
|
if (APUController.APU != nil) {
|
||||||
|
|
|
@ -183,6 +183,27 @@
|
||||||
<output>/systems/apu/oil/level-l</output>
|
<output>/systems/apu/oil/level-l</output>
|
||||||
</fcs_function>
|
</fcs_function>
|
||||||
|
|
||||||
|
<switch name="/systems/apu/shutdown-power-loss-cmd">
|
||||||
|
<default value="0"/>
|
||||||
|
<test logic="AND" value="1">
|
||||||
|
/systems/electrical/bus/dc-bat lt 25
|
||||||
|
</test>
|
||||||
|
</switch>
|
||||||
|
|
||||||
|
<actuator name="/systems/apu/shutdown-power-loss-timer">
|
||||||
|
<input>/systems/apu/shutdown-power-loss-cmd</input>
|
||||||
|
<rate_limit sense="incr">5</rate_limit>
|
||||||
|
<rate_limit sense="decr">100</rate_limit>
|
||||||
|
</actuator>
|
||||||
|
|
||||||
|
<switch name="/systems/apu/shutdown-power-loss">
|
||||||
|
<default value="0"/>
|
||||||
|
<test logic="AND" value="1">
|
||||||
|
/systems/apu/shutdown-power-loss-timer eq 1
|
||||||
|
</test>
|
||||||
|
</switch>
|
||||||
|
|
||||||
|
|
||||||
</channel>
|
</channel>
|
||||||
|
|
||||||
</system>
|
</system>
|
||||||
|
|