@ -456,7 +456,7 @@
<switch name="/systems/fuel/apu-feed-pump">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND" value="1">
/systems/fuel/pumps/apu-operate eq 1
/systems/fuel/valves/apu-lp-valve eq 1
</test>
@ -551,7 +551,6 @@
/systems/fuel/apu-feed-pump eq 1
</test>
/consumables/fuel/tank[2]/level-gal_us gt /consumables/fuel/tank[2]/unusable-gal_us
propulsion/tank[5]/contents-lbs lt 9
</test>
<test logic="AND" value="1"> <!-- left -->
<test logic="OR">
@ -559,7 +558,6 @@
/systems/fuel/apu-feed-pump eq 1
</test>
/consumables/fuel/tank[1]/level-gal_us gt /consumables/fuel/tank[1]/unusable-gal_us
propulsion/tank[5]/contents-lbs lt 9
</test>
<test logic="AND" value="3"> <!-- right -->
<test logic="OR">
@ -568,7 +566,6 @@
</test>
/systems/fuel/valves/crossfeed-valve eq 1
/consumables/fuel/tank[3]/level-gal_us gt /consumables/fuel/tank[3]/unusable-gal_us
propulsion/tank[5]/contents-lbs lt 9
</test>
</switch>