diff --git a/Nasal/ECAM/ECAM-logic.nas b/Nasal/ECAM/ECAM-logic.nas
index 526caaed..5b834670 100644
--- a/Nasal/ECAM/ECAM-logic.nas
+++ b/Nasal/ECAM/ECAM-logic.nas
@@ -1535,7 +1535,7 @@ var messages_priority_2 = func {
ECAM_controller.warningReset(eng2BleedLowTempIcing);
}
- if (eng1BleedNotClsd.clearFlag == 0 and (phaseVar <= 2 or phaseVar >= 9 or phaseVar == 6) and warningNodes.Timers.bleed1NotShutOutput.getBoolValue()) {
+ if (eng1BleedNotClsd.clearFlag == 0 and (phaseVar <= 2 or phaseVar >= 9 or phaseVar == 6) and warningNodes.Timers.bleed1NotShutOutput.getValue() == 1) {
eng1BleedNotClsd.active = 1;
if (systems.PNEU.Switch.bleed1.getBoolValue()) {
eng1BleedNotClsdOff.active = 1;
@@ -1547,7 +1547,7 @@ var messages_priority_2 = func {
ECAM_controller.warningReset(eng1BleedNotClsdOff);
}
- if (eng2BleedNotClsd.clearFlag == 0 and (phaseVar <= 2 or phaseVar >= 9 or phaseVar == 6) and warningNodes.Timers.bleed2NotShutOutput.getBoolValue()) {
+ if (eng2BleedNotClsd.clearFlag == 0 and (phaseVar <= 2 or phaseVar >= 9 or phaseVar == 6) and warningNodes.Timers.bleed2NotShutOutput.getValue == 1) {
eng2BleedNotClsd.active = 1;
if (systems.PNEU.Switch.bleed2.getBoolValue()) {
eng2BleedNotClsdOff.active = 1;
diff --git a/Systems/a320-pneumatic.xml b/Systems/a320-pneumatic.xml
index 51a99d3a..99fbdbbb 100644
--- a/Systems/a320-pneumatic.xml
+++ b/Systems/a320-pneumatic.xml
@@ -764,7 +764,7 @@
/systems/pneumatics/valves/engine-2-prv-valve
/systems/pneumatics/valves/engine-2-opv-valve
/engines/engine[1]/egt-actual
- 0.36
+ 2.45
/systems/pneumatics/valves/apu-bleed-valve