Hydraulics: correct PTU function, fire valves

This commit is contained in:
legoboyvdlp R 2019-10-15 19:03:43 +01:00
parent ebe4d5aa3c
commit 5046369761
4 changed files with 161 additions and 77 deletions

View file

@ -30,9 +30,6 @@ var leftdoor = 0;
var rightdoor = 0;
var nosedoor = 0;
var gearlvr = 0;
var askidsw = 0;
var brakemode = 0;
var accum = 0;
var elapsedtime = 0;
var tr1_v = 0;
var tr1_a = 0;
@ -72,7 +69,7 @@ var aileron_ind_right = props.globals.getNode("/ECAM/Lower/aileron-ind-right", 1
var elevator_ind_left = props.globals.getNode("/ECAM/Lower/elevator-ind-left", 1);
var elevator_ind_right = props.globals.getNode("/ECAM/Lower/elevator-ind-right", 1);
var elevator_trim_deg = props.globals.getNode("/ECAM/Lower/elevator-trim-deg", 1);
var final_deg = props.globals.getNode("/fdm/jsbsim/hydraulics/rudder/final-deg", 1);
var final_deg = props.globals.getNode("/fdm/jsbsim/hydraulic/rudder/final-deg", 1);
var temperature_degc = props.globals.getNode("/environment/temperature-degc", 1);
var gw = props.globals.getNode("/FMGC/internal/gw", 1);
var tank3_content_lbs = props.globals.getNode("/fdm/jsbsim/propulsion/tank[2]/contents-lbs", 1);
@ -164,23 +161,37 @@ var tr2_fault = props.globals.getNode("/systems/failures/electrical/tr-2", 1);
var essTrVolt = props.globals.getNode("/systems/electrical/relay/dc-ess-feed-tr/output", 1);
var essTrAmp = props.globals.getNode("/systems/electrical/relay/dc-ess-feed-tr/output-amp", 1);
# Hydraulic
var blue_psi = 0;
var green_psi = 0;
var yellow_psi = 0;
var y_resv_lo_air_press = props.globals.getNode("/systems/hydraulic/yellow-resv-lo-air-press", 1);
var b_resv_lo_air_press = props.globals.getNode("/systems/hydraulic/blue-resv-lo-air-press", 1);
var g_resv_lo_air_press = props.globals.getNode("/systems/hydraulic/green-resv-lo-air-press", 1);
var elec_pump_y_ovht = props.globals.getNode("/systems/hydraulic/elec-pump-yellow-ovht", 1);
var elec_pump_b_ovht = props.globals.getNode("/systems/hydraulic/elec-pump-blue-ovht", 1);
var rat_deployed = props.globals.getNode("/controls/hydraulic/rat-deployed", 1);
var y_resv_ovht = props.globals.getNode("/systems/hydraulic/yellow-resv-ovht", 1);
var b_resv_ovht = props.globals.getNode("/systems/hydraulic/blue-resv-ovht", 1);
var g_resv_ovht = props.globals.getNode("/systems/hydraulic/green-resv-ovht", 1);
var askidsw = 0;
var brakemode = 0;
var accum = 0;
var eng1_running = props.globals.getNode("/engines/engine[0]/running", 1);
var eng2_running = props.globals.getNode("/engines/engine[1]/running", 1);
var switch_cart = props.globals.getNode("/controls/electrical/ground-cart", 1);
var total_psi = props.globals.getNode("/systems/pneumatic/total-psi", 1);
var b_psi = props.globals.getNode("/systems/hydraulic/blue-psi", 1);
var g_psi = props.globals.getNode("/systems/hydraulic/green-psi", 1);
var y_psi = props.globals.getNode("/systems/hydraulic/yellow-psi", 1);
var spoiler_L1 = props.globals.getNode("/fdm/jsbsim/hydraulics/spoiler-l1/final-deg", 1);
var spoiler_L2 = props.globals.getNode("/fdm/jsbsim/hydraulics/spoiler-l2/final-deg", 1);
var spoiler_L3 = props.globals.getNode("/fdm/jsbsim/hydraulics/spoiler-l3/final-deg", 1);
var spoiler_L4 = props.globals.getNode("/fdm/jsbsim/hydraulics/spoiler-l4/final-deg", 1);
var spoiler_L5 = props.globals.getNode("/fdm/jsbsim/hydraulics/spoiler-l5/final-deg", 1);
var spoiler_R1 = props.globals.getNode("/fdm/jsbsim/hydraulics/spoiler-r1/final-deg", 1);
var spoiler_R2 = props.globals.getNode("/fdm/jsbsim/hydraulics/spoiler-r2/final-deg", 1);
var spoiler_R3 = props.globals.getNode("/fdm/jsbsim/hydraulics/spoiler-r3/final-deg", 1);
var spoiler_R4 = props.globals.getNode("/fdm/jsbsim/hydraulics/spoiler-r4/final-deg", 1);
var spoiler_R5 = props.globals.getNode("/fdm/jsbsim/hydraulics/spoiler-r5/final-deg", 1);
var spoiler_L1 = props.globals.getNode("/fdm/jsbsim/hydraulic/spoiler-l1/final-deg", 1);
var spoiler_L2 = props.globals.getNode("/fdm/jsbsim/hydraulic/spoiler-l2/final-deg", 1);
var spoiler_L3 = props.globals.getNode("/fdm/jsbsim/hydraulic/spoiler-l3/final-deg", 1);
var spoiler_L4 = props.globals.getNode("/fdm/jsbsim/hydraulic/spoiler-l4/final-deg", 1);
var spoiler_L5 = props.globals.getNode("/fdm/jsbsim/hydraulic/spoiler-l5/final-deg", 1);
var spoiler_R1 = props.globals.getNode("/fdm/jsbsim/hydraulic/spoiler-r1/final-deg", 1);
var spoiler_R2 = props.globals.getNode("/fdm/jsbsim/hydraulic/spoiler-r2/final-deg", 1);
var spoiler_R3 = props.globals.getNode("/fdm/jsbsim/hydraulic/spoiler-r3/final-deg", 1);
var spoiler_R4 = props.globals.getNode("/fdm/jsbsim/hydraulic/spoiler-r4/final-deg", 1);
var spoiler_R5 = props.globals.getNode("/fdm/jsbsim/hydraulic/spoiler-r5/final-deg", 1);
var spoiler_L1_fail = props.globals.getNode("/systems/failures/spoiler-l1", 1);
var spoiler_L2_fail = props.globals.getNode("/systems/failures/spoiler-l2", 1);
var spoiler_L3_fail = props.globals.getNode("/systems/failures/spoiler-l3", 1);
@ -217,25 +228,6 @@ var tank1pump1 = props.globals.getNode("controls/fuel/tank1pump1", 1);
var tank1pump2 = props.globals.getNode("controls/fuel/tank1pump2", 1);
var tank2pump1 = props.globals.getNode("controls/fuel/tank2pump1", 1);
var tank2pump2 = props.globals.getNode("controls/fuel/tank2pump2", 1);
var ptu = props.globals.getNode("/controls/hydraulic/ptu", 1);
var ptu_fault = props.globals.getNode("/systems/hydraulic/ptu-fault", 1);
var ptu_active = props.globals.getNode("/systems/hydraulic/ptu-active", 1);
var ptu_supplies = props.globals.getNode("/systems/hydraulic/ptu-supplies", 1);
var eng1_pump = props.globals.getNode("/controls/hydraulic/eng1-pump", 1);
var eng2_pump = props.globals.getNode("/controls/hydraulic/eng2-pump", 1);
var elec_pump_blue = props.globals.getNode("/controls/hydraulic/elec-pump-blue", 1);
var elec_pump_yellow = props.globals.getNode("/controls/hydraulic/elec-pump-yellow", 1);
var y_resv_lo_air_press = props.globals.getNode("/systems/hydraulic/yellow-resv-lo-air-press", 1);
var b_resv_lo_air_press = props.globals.getNode("/systems/hydraulic/blue-resv-lo-air-press", 1);
var g_resv_lo_air_press = props.globals.getNode("/systems/hydraulic/green-resv-lo-air-press", 1);
var elec_pump_y_ovht = props.globals.getNode("/systems/hydraulic/elec-pump-yellow-ovht", 1);
var elec_pump_b_ovht = props.globals.getNode("/systems/hydraulic/elec-pump-blue-ovht", 1);
var rat_deployed = props.globals.getNode("/controls/hydraulic/rat-deployed", 1);
var y_resv_ovht = props.globals.getNode("/systems/hydraulic/yellow-resv-ovht", 1);
var b_resv_ovht = props.globals.getNode("/systems/hydraulic/blue-resv-ovht", 1);
var g_resv_ovht = props.globals.getNode("/systems/hydraulic/green-resv-ovht", 1);
var y_fire_valve = props.globals.getNode("/systems/hydraulic/yellow-fire-valve", 1);
var g_fire_valve = props.globals.getNode("/systems/hydraulic/green-fire-valve", 1);
var autobreak_mode = props.globals.getNode("/controls/autobrake/mode", 1);
var gear1_pos = props.globals.getNode("gear/gear[0]/position-norm", 1);
var gear2_pos = props.globals.getNode("gear/gear[1]/position-norm", 1);
@ -244,9 +236,6 @@ var gear_door_L = props.globals.getNode("/systems/hydraulic/gear/door-left", 1);
var gear_door_R = props.globals.getNode("/systems/hydraulic/gear/door-right", 1);
var gear_door_N = props.globals.getNode("/systems/hydraulic/gear/door-nose", 1);
var gear_down = props.globals.getNode("/controls/gear/gear-down", 1);
var askid = props.globals.getNode("/systems/hydraulic/brakes/askidnwssw", 1);
var brk_mode = props.globals.getNode("/systems/hydraulic/brakes/mode", 1);
var accu_press = props.globals.getNode("/systems/hydraulic/brakes/accumulator-pressure-psi", 1);
var press_vs_norm = props.globals.getNode("/systems/pressurization/vs-norm", 1);
var cabinalt = props.globals.getNode("/systems/pressurization/cabinalt-norm", 1);
var gear0_wow = props.globals.getNode("/gear/gear[0]/wow", 1);
@ -1847,9 +1836,9 @@ var canvas_lowerECAM_fctl = {
"spoiler5Lf","ailLscale","ailRscale","path4249","path4249-3","path4249-3-6-7","path4249-3-6-7-5","path4249-3-6"];
},
update: func() {
blue_psi = b_psi.getValue();
green_psi = g_psi.getValue();
yellow_psi = y_psi.getValue();
blue_psi = systems.HYD.Psi.blue.getValue();
green_psi = systems.HYD.Psi.green.getValue();
yellow_psi = systems.HYD.Psi.yellow.getValue();
# Pitch Trim
me["PT"].setText(sprintf("%2.1f", math.round(elevator_trim_deg.getValue(), 0.1)));
@ -2442,9 +2431,9 @@ var canvas_lowerECAM_hyd = {
"LO-AIR-PRESS-Yellow","LO-AIR-PRESS-Blue","OVHT-Green","OVHT-Blue","OVHT-Yellow","Quantity-Indicator-Green","Quantity-Indicator-Blue","Quantity-Indicator-Yellow","Green-label","Blue-label","Yellow-label"];
},
update: func() {
blue_psi = b_psi.getValue();
green_psi = g_psi.getValue();
yellow_psi = y_psi.getValue();
blue_psi = systems.HYD.Psi.blue.getValue();
green_psi = systems.HYD.Psi.green.getValue();
yellow_psi = systems.HYD.Psi.yellow.getValue();
me["Press-Green"].setText(sprintf("%s", math.round(green_psi, 50)));
me["Press-Blue"].setText(sprintf("%s", math.round(blue_psi, 50)));
@ -2491,12 +2480,12 @@ var canvas_lowerECAM_hyd = {
me["Press-Green"].setColor(0.7333,0.3803,0);
me["Green-label"].setColor(0.7333,0.3803,0);
}
if (ptu.getValue() == 1 and ptu_fault.getValue() == 0) {
if (systems.HYD.Switch.ptu.getValue() and !systems.HYD.Fail.ptuFault.getValue()) {
me["PTU-connection"].setColor(0.0509,0.7529,0.2941);
if (ptu_active.getValue() == 1) {
if (ptu_supplies.getValue() == "yellow") {
if (systems.HYD.Ptu.active.getValue()) {
if (systems.HYD.Ptu.diff.getValue() < 0) {
me["PTU-Supply-Line"].show();
me["PTU-supply-yellow"].show();
me["PTU-supply-green"].hide();
@ -2535,7 +2524,7 @@ var canvas_lowerECAM_hyd = {
me["Pump-Yellow-label"].setColor(0.7333,0.3803,0);
}
if (eng1_pump.getValue() == 1) {
if (systems.HYD.Switch.greenEDP.getValue()) {
me["Pump-Green-off"].hide();
if (green_psi >= 1500) {
me["Pump-Green-on"].show();
@ -2555,7 +2544,7 @@ var canvas_lowerECAM_hyd = {
me["Pump-Green"].setColor(0.7333,0.3803,0);
}
if (eng2_pump.getValue() == 1) {
if (systems.HYD.Switch.yellowEDP.getValue()) {
me["Pump-Yellow-off"].hide();
if (yellow_psi >= 1500) {
me["Pump-Yellow-on"].show();
@ -2576,7 +2565,7 @@ var canvas_lowerECAM_hyd = {
me["Pump-Yellow"].setColor(0.7333,0.3803,0);
}
if (elec_pump_blue.getValue() == 1) {
if (systems.HYD.Switch.blueElec.getValue()) {
me["Pump-Blue-off"].hide();
if (blue_psi >= 1500) {
me["Pump-Blue-on"].show();
@ -2596,7 +2585,7 @@ var canvas_lowerECAM_hyd = {
me["Pump-Blue"].setColor(0.7333,0.3803,0);
}
if (elec_pump_yellow.getValue() == 0) {
if (!systems.HYD.Switch.yellowElec.getValue()) {
me["ELEC-Yellow-on"].hide();
me["ELEC-Yellow-off"].show();
} else {
@ -2639,7 +2628,7 @@ var canvas_lowerECAM_hyd = {
me["ELEC-OVHT-Blue"].hide();
}
if (rat_deployed.getValue() == 1) {
if (systems.HYD.Rat.position.getValue() == 1) {
me["RAT-stowed"].hide();
me["RAT-not-stowed"].show();
} else {
@ -2665,19 +2654,19 @@ var canvas_lowerECAM_hyd = {
me["OVHT-Blue"].hide();
}
if (ac1.getValue() > 110) {
if (systems.ELEC.Bus.ac1.getValue() > 110) {
me["ELEC-Blue-label"].setColor(0.8078,0.8039,0.8078);
} else {
me["ELEC-Blue-label"].setColor(0.7333,0.3803,0);
}
if (ac2.getValue() > 110) {
if (systems.ELEC.Bus.ac2.getValue() > 110) {
me["ELEC-Yellow-label"].setColor(0.8078,0.8039,0.8078);
} else {
me["ELEC-Yellow-label"].setColor(0.7333,0.3803,0);
}
if (y_fire_valve.getValue() == 1) {
if (systems.HYD.Valve.yellowFire.getValue() != 0) {
me["Fire-Valve-Yellow"].setColor(0.7333,0.3803,0);
me["Fire-Valve-Yellow"].setRotation(90 * D2R);
} else {
@ -2685,7 +2674,7 @@ var canvas_lowerECAM_hyd = {
me["Fire-Valve-Yellow"].setRotation(0);
}
if (g_fire_valve.getValue() == 1) {
if (systems.HYD.Valve.greenFire.getValue() != 0) {
me["Fire-Valve-Green"].setColor(0.7333,0.3803,0);
me["Fire-Valve-Green"].setRotation(90 * D2R);
} else {
@ -2711,9 +2700,9 @@ var canvas_lowerECAM_wheel = {
"braketemp2","braketemp3","braketemp4","leftuplock","noseuplock","rightuplock","Triangle-Left1","Triangle-Left2","Triangle-Nose1","Triangle-Nose2","Triangle-Right1","Triangle-Right2","BSCUrect1","BSCUrect2","BSCU1","BSCU2"];
},
update: func() {
blue_psi = b_psi.getValue();
green_psi = g_psi.getValue();
yellow_psi = y_psi.getValue();
blue_psi = systems.HYD.Psi.blue.getValue();
green_psi = systems.HYD.Psi.green.getValue();
yellow_psi = systems.HYD.Psi.yellow.getValue();
autobrakemode = autobreak_mode.getValue();
nosegear = gear1_pos.getValue();
leftgear = gear2_pos.getValue();
@ -2722,9 +2711,9 @@ var canvas_lowerECAM_wheel = {
rightdoor = gear_door_R.getValue();
nosedoor = gear_door_N.getValue();
gearlvr = gear_down.getValue();
askidsw = askid.getValue();
brakemode = brk_mode.getValue();
accum = accu_press.getValue();
askidsw = systems.HYD.Brakes.askidSw.getBoolValue();
brakemode = systems.HYD.Brakes.mode.getBoolValue();
accum = systems.HYD.Brakes.accumPressPsi.getBoolValue();
# L/G CTL
if ((leftgear == 0 or nosegear == 0 or rightgear == 0 and gearlvr == 0) or (leftgear == 1 or nosegear == 1 or rightgear == 1 and gearlvr == 1)) {

View file

@ -3,8 +3,24 @@
# Copyright (c) 2019 Jonathan Redpath
var accum = 0;
var parking = 0;
var askidnws_sw = 0;
var down = 0;
var HYD = {
Brakes: {
accumPressPsi: props.globals.initNode("/systems/hydraulic/brakes/accumulator-pressure-psi", 0, "INT"),
accumPressPsi1: props.globals.initNode("/systems/hydraulic/brakes/accumulator-pressure-psi-1", 0, "INT"),
leftPressPsi: props.globals.initNode("/systems/hydraulic/brakes/pressure-left-psi", 0, "INT"),
rightPressPsi: props.globals.initNode("/systems/hydraulic/brakes/pressure-right-psi", 0, "INT"),
askidSw: props.globals.initNode("/systems/hydraulic/brakes/askidnwssw", 1, "BOOL"),
mode: props.globals.initNode("/systems/hydraulic/brakes/mode", 0, "INT"),
lbrake: props.globals.initNode("/systems/hydraulic/brakes/lbrake", 0, "INT"),
rbrake: props.globals.initNode("/systems/hydraulic/brakes/rbrake", 0, "INT"),
noserubber: props.globals.initNode("/systems/hydraulic/brakes/nose-rubber", 0, "INT"),
counter: props.globals.initNode("/systems/hydraulic/brakes/counter", 0, "INT"),
},
Fail: {
blueElec: props.globals.getNode("/systems/failures/hydraulic/blue-elec"),
blueLeak: props.globals.getNode("/systems/failures/hydraulic/blue-leak"),
@ -16,12 +32,22 @@ var HYD = {
yellowLeak: props.globals.getNode("/systems/failures/hydraulic/yellow-leak"),
},
Psi: {
blue: props.globals.getNode("/systems/hydraulic/blue-psi"),
green: props.globals.getNode("/systems/hydraulic/green-psi"),
yellow: props.globals.getNode("/systems/hydraulic/yellow-psi"),
},
Ptu: {
active: props.globals.getNode("/systems/hydraulic/sources/ptu/ptu-active"),
diff: props.globals.getNode("/systems/hydraulic/yellow-psi-diff"),
},
Qty: {
blueInput: props.globals.initNode("/systems/hydraulic/blue-qty-input", 0, "INT"),
greenInput: props.globals.initNode("/systems/hydraulic/green-qty-input", 0, "INT"),
yellowInput: props.globals.initNode("/systems/hydraulic/yellow-qty-input", 0, "INT"),
},
Rat: {
position: props.globals.getNode("/systems/hydraulic/sources/rat/position"),
},
Switch: {
blueElec: props.globals.getNode("/controls/hydraulic/switches/blue-elec"),
blueElecOvrd: props.globals.getNode("/controls/hydraulic/switches/blue-elec-ovrd"),
@ -31,6 +57,10 @@ var HYD = {
yellowEDP: props.globals.getNode("/controls/hydraulic/switches/yellow-edp"),
yellowElec: props.globals.getNode("/controls/hydraulic/switches/yellow-elec"),
},
Valve: {
yellowFire: props.globals.getNode("/systems/hydraulics/sources/yellow-edp/fire-valve"),
greenFire: props.globals.getNode("/systems/hydraulics/sources/green-edp/fire-valve"),
},
init: func() {
me.resetFail();
me.Qty.blueInput.setValue(math.round((rand() * 4) + 8 , 0.1)); # Random between 8 and 12
@ -55,6 +85,24 @@ var HYD = {
me.Fail.yellowLeak.setBoolValue(0);
},
loop: func() {
accum = me.Brakes.accumPressPsi.getValue();
parking = getprop("/controls/gear/brake-parking");
askidnws_sw = me.Brakes.askidSw.getBoolValue();
if (!parking and askidnws_sw and me.Psi.green.getValue() > 2500) {
# set mode to on
me.Brakes.mode.setValue(1);
} else if ((!parking and askidnws_sw and me.Psi.yellow.getValue() > 2500) or (!parking and askidnws_sw and accum > 0)) {
# set mode to altn
me.Brakes.mode.setValue(2);
} else {
# set mode to off
me.Brakes.mode.setValue(0);
}
if (me.Brakes.mode.getValue() == 2 and me.Psi.yellow.getValue() > 2500 and accum < 700) {
me.Brakes.accumPressPsi.setValue(me.Brakes.accumPressPsi.getValue() + 50);
}
},
};

View file

@ -1096,8 +1096,10 @@
<test logic="AND" value="1">
/systems/electrical/bus/ac-1 lt 110
/systems/electrical/bus/ac-2 lt 110
/systems/acconfig/autoconfig-running ne 1
</test>
<test logic="AND" value="1">
/systems/acconfig/autoconfig-running ne 1
/systems/electrical/relay/ext-epc/contact-pos eq 0
<test logic="OR">
/controls/electrical/switches/gen-1 eq 0

View file

@ -101,13 +101,20 @@
<fcs_function name="/systems/hydraulic/sources/rat/source-psi">
<function>
<table>
<independentVar lookup="row">/instrumentation/airspeed-indicator/indicated-speed-kt</independentVar>
<tableData>
99 0
100 2500
</tableData>
</table>
<ifthen>
<eq>
<property>/systems/hydraulic/sources/rat/position</property>
<value>1</value>
</eq>
<table>
<independentVar lookup="row">/instrumentation/airspeed-indicator/indicated-speed-kt</independentVar>
<tableData>
99 0
100 2500
</tableData>
</table>
<value>0</value>
</ifthen>
</function>
</fcs_function>
@ -207,10 +214,16 @@
</function>
</fcs_function>
<actuator name="/systems/hydraulic/sources/green-edp/fire-valve">
<input>/controls/engines/engine[0]/fire-btn</input>
<rate_limit>0.25</rate_limit> <!-- 4 seconds -->
</actuator>
<switch name="/systems/hydraulic/sources/green-edp/output-psi">
<default value="0"/>
<test value="/systems/hydraulic/sources/green-edp/source-psi">
/controls/hydraulic/switches/green-edp eq 1
/systems/hydraulic/sources/green-edp/fire-valve lt 0.10
</test>
</switch>
@ -272,10 +285,16 @@
</function>
</fcs_function>
<actuator name="/systems/hydraulic/sources/yellow-edp/fire-valve">
<input>/controls/engines/engine[1]/fire-btn</input>
<rate_limit>0.25</rate_limit> <!-- 4 seconds -->
</actuator>
<switch name="/systems/hydraulic/sources/yellow-edp/output-psi">
<default value="0"/>
<test value="/systems/hydraulic/sources/yellow-edp/source-psi">
/controls/hydraulic/switches/yellow-edp eq 1
/systems/hydraulic/sources/yellow-edp/fire-valve lt 0.10
</test>
</switch>
@ -338,6 +357,11 @@
<rate_limit sense="decr">/systems/hydraulic/sys-decr-rate</rate_limit>
</actuator>
<pure_gain name="/systems/hydraulic/green-psi-ptu">
<input>/systems/hydraulic/green-psi</input>
<gain>0.9</gain>
</pure_gain>
<!-- Yellow PSI -->
<fcs_function name="/systems/hydraulic/yellow-psi-cmd-pump">
<function>
@ -377,6 +401,11 @@
<rate_limit sense="decr">/systems/hydraulic/sys-decr-rate</rate_limit>
</actuator>
<pure_gain name="/systems/hydraulic/yellow-psi-ptu">
<input>/systems/hydraulic/yellow-psi</input>
<gain>0.9</gain>
</pure_gain>
<!-- PTU -->
<fcs_function name="/systems/hydraulic/yellow-psi-diff">
<function>
@ -388,30 +417,46 @@
</fcs_function>
<switch name="/systems/hydraulic/sources/ptu/ptu-active">
<default value="0"/>
<test logic="OR" value="1">
/systems/hydraulic/yellow-psi-diff gt 500
/systems/hydraulic/yellow-psi-diff lt -500
<test logic="AND" value="0">
/systems/hydraulic/yellow-psi-diff gt -250
/systems/hydraulic/yellow-psi-diff lt 250
/systems/hydraulic/sources/ptu/ptu-active eq 1
</test>
<test logic="AND" value="1">
<test logic="OR">
/systems/hydraulic/yellow-psi-diff ge 250
/systems/hydraulic/yellow-psi-diff le -250
</test>
/systems/hydraulic/sources/ptu/ptu-active eq 1
</test>
<test logic="AND" value="1">
<test logic="OR">
/systems/hydraulic/yellow-psi-diff gt 500
/systems/hydraulic/yellow-psi-diff lt -500
</test>
/systems/hydraulic/sources/ptu/ptu-active eq 0
</test>
</switch>
<switch name="/systems/hydraulic/sources/ptu/green-yellow">
<default value="0"/>
<test logic="AND" value="/systems/hydraulic/green-psi">
<test logic="AND" value="/systems/hydraulic/green-psi-ptu">
/controls/hydraulic/switches/ptu eq 1
/systems/hydraulic/sources/ptu/ptu-active eq 1
/systems/electrical/bus/dc-2 ge 25
/systems/failures/hydraulic/ptu ne 1
/systems/hydraulic/sources/yellow-edp/fire-valve lt 0.10
</test>
</switch>
<switch name="/systems/hydraulic/sources/ptu/yellow-green">
<default value="0"/>
<test logic="AND" value="/systems/hydraulic/yellow-psi">
<test logic="AND" value="/systems/hydraulic/yellow-psi-ptu">
/controls/hydraulic/switches/ptu eq 1
/systems/hydraulic/sources/ptu/ptu-active eq 1
/systems/electrical/bus/dc-2 ge 25
/systems/failures/hydraulic/ptu ne 1
/systems/hydraulic/sources/green-edp/fire-valve lt 0.10
</test>
</switch>