Make the batteries drain when static inverter is active
This commit is contained in:
parent
d6344cca6e
commit
443207e9b6
1 changed files with 10 additions and 2 deletions
|
@ -87,8 +87,12 @@
|
|||
|
||||
<switch name="/systems/electrical/sources/bat-1/direction">
|
||||
<default value="0"/>
|
||||
<test value="0">
|
||||
<test logic="AND" value="0">
|
||||
/systems/electrical/sources/bat-1/contact eq 0
|
||||
/systems/electrical/sources/si-1/inverter-active eq 0
|
||||
</test>
|
||||
<test logic="AND" value="1">
|
||||
/systems/electrical/sources/si-1/inverter-active eq 1
|
||||
</test>
|
||||
<test logic="AND" value="1"> <!-- drain -->
|
||||
/systems/electrical/sources/bat-1/contact eq 1
|
||||
|
@ -253,8 +257,12 @@
|
|||
|
||||
<switch name="/systems/electrical/sources/bat-2/direction">
|
||||
<default value="0"/>
|
||||
<test value="0">
|
||||
<test logic="AND" value="0">
|
||||
/systems/electrical/sources/bat-2/contact eq 0
|
||||
/systems/electrical/sources/si-1/inverter-active eq 0
|
||||
</test>
|
||||
<test logic="AND" value="1">
|
||||
/systems/electrical/sources/si-1/inverter-active eq 1
|
||||
</test>
|
||||
<test logic="AND" value="1"> <!-- drain -->
|
||||
/systems/electrical/sources/bat-2/contact eq 1
|
||||
|
|
Loading…