Systems should run at 15hz rather than 120hz
This commit is contained in:
parent
76e3d5fe2b
commit
3dca066455
9 changed files with 25 additions and 25 deletions
|
@ -5,7 +5,7 @@
|
|||
|
||||
<system name="A320: ADR">
|
||||
|
||||
<channel name="ADR Inputs">
|
||||
<channel name="ADR Inputs" execrate="2">
|
||||
|
||||
<sensor name="/systems/navigation/probes/aoa-1">
|
||||
<input>aero/alpha-deg-norm</input>
|
||||
|
@ -128,7 +128,7 @@
|
|||
|
||||
</channel>
|
||||
|
||||
<channel name="ADR Computation">
|
||||
<channel name="ADR Computation" execrate="2">
|
||||
|
||||
<sensor name="/systems/navigation/adr/computation/baro-alt-1-capt">
|
||||
<input>/instrumentation/altimeter[0]/pressure-alt-ft</input>
|
||||
|
@ -755,7 +755,7 @@
|
|||
|
||||
</channel>
|
||||
|
||||
<channel name="ADR Output"> <!-- todo - need lowpass? -->
|
||||
<channel name="ADR Output" execrate="2"> <!-- todo - need lowpass? -->
|
||||
|
||||
<pure_gain name="/systems/navigation/adr/output/aoa-1">
|
||||
<input>/systems/navigation/probes/aoa-1</input>
|
||||
|
|
|
@ -5,7 +5,7 @@
|
|||
<property value="0">/systems/air-conditioning/packs/pack-flow-1-norm</property>
|
||||
<property value="0">/systems/air-conditioning/packs/pack-flow-2-norm</property>
|
||||
|
||||
<channel name="Valves">
|
||||
<channel name="Valves" execrate="8">
|
||||
|
||||
<switch name="/systems/air-conditioning/valves/flow-control-valve-1-cmd">
|
||||
<default value="0"/>
|
||||
|
@ -100,7 +100,7 @@
|
|||
|
||||
</channel>
|
||||
|
||||
<channel name="Packs">
|
||||
<channel name="Packs" execrate="8">
|
||||
|
||||
<switch name="/systems/air-conditioning/packs/single-pack">
|
||||
<default value="0"/>
|
||||
|
@ -727,11 +727,11 @@
|
|||
</actuator>
|
||||
</channel>
|
||||
|
||||
<channel name="Recirculation">
|
||||
<channel name="Recirculation" execrate="8">
|
||||
|
||||
</channel>
|
||||
|
||||
<channel name="Mass flow">
|
||||
<channel name="Mass flow" execrate="8">
|
||||
|
||||
<fcs_function name="/systems/air-conditioning/mass-flow-fresh-kg_s">
|
||||
<function>
|
||||
|
@ -798,7 +798,7 @@
|
|||
|
||||
</channel>
|
||||
|
||||
<channel name="Warnings">
|
||||
<channel name="Warnings" execrate="8">
|
||||
|
||||
<switch name="/systems/air-conditioning/warnings/pack-1-ovht">
|
||||
<default value="0"/>
|
||||
|
|
|
@ -5,7 +5,7 @@
|
|||
|
||||
<system name="A320: APU">
|
||||
|
||||
<channel name="APU">
|
||||
<channel name="APU" execrate="8">
|
||||
<!-- bleed 1.8 kg / sec @ 42 psig -->
|
||||
<!-- fuel 148 kg/hr -->
|
||||
<!-- generator 24034 rpm, 10129 rpm fuel ctl, 32045 rpm starter, 51965 rpm cooling, 4137rpm oil pump -->
|
||||
|
|
|
@ -4,7 +4,7 @@
|
|||
|
||||
<system name="A320: Engine Fire">
|
||||
|
||||
<channel name="Engine Fire">
|
||||
<channel name="Engine Fire" execrate="8">
|
||||
<fcs_function name="enginefire1">
|
||||
<function>
|
||||
<sum>
|
||||
|
@ -75,7 +75,7 @@
|
|||
</fcs_function>
|
||||
</channel>
|
||||
|
||||
<channel name="Cargo Fire">
|
||||
<channel name="Cargo Fire" execrate="8">
|
||||
<fcs_function name="fwdfire">
|
||||
<function>
|
||||
<sum>
|
||||
|
|
|
@ -5,7 +5,7 @@
|
|||
|
||||
<system name="A320: Fuel:">
|
||||
|
||||
<channel name="Fuel Pumps and Valves">
|
||||
<channel name="Fuel Pumps and Valves" execrate="8">
|
||||
<!-- Pumps -->
|
||||
|
||||
<switch name="/systems/fuel/pumps/apu-operate"> <!-- DC HOT 1 ? -->
|
||||
|
@ -409,7 +409,7 @@
|
|||
</actuator>
|
||||
</channel>
|
||||
|
||||
<channel name="Flow Rates">
|
||||
<channel name="Flow Rates" execrate="2">
|
||||
|
||||
<switch name="/systems/fuel/feed-left-inner">
|
||||
<default value="0"/>
|
||||
|
@ -793,7 +793,7 @@
|
|||
</summer>
|
||||
</channel>
|
||||
|
||||
<channel name="Warnings">
|
||||
<channel name="Warnings" execrate="8">
|
||||
|
||||
<summer name="/systems/fuel/quantity/left-wing-kg">
|
||||
<input>/consumables/fuel/tank[0]/level-kg</input>
|
||||
|
|
|
@ -14,7 +14,7 @@
|
|||
</actuator>
|
||||
</channel>
|
||||
|
||||
<channel name="FWC Phase Logic and Switches">
|
||||
<channel name="FWC Phase Logic and Switches" execrate="4">
|
||||
|
||||
<switch name="/ECAM/flipflop/speed-gt-80-set">
|
||||
<default value="0"/>
|
||||
|
|
|
@ -4,7 +4,7 @@
|
|||
|
||||
<system name="A320: Lights">
|
||||
|
||||
<channel name="Interior Lights">
|
||||
<channel name="Interior Lights" execrate="8">
|
||||
<switch name="/controls/lighting/reading-light-tied">
|
||||
<default value="0" />
|
||||
<test value="/controls/lighting/main-flood-knb">
|
||||
|
@ -70,7 +70,7 @@
|
|||
</switch>
|
||||
</channel>
|
||||
|
||||
<channel name="Exterior Lights">
|
||||
<channel name="Exterior Lights" execrate="8">
|
||||
|
||||
<switch name="/sim/model/lights/nose-lights">
|
||||
<default value="0"/>
|
||||
|
|
|
@ -1,7 +1,7 @@
|
|||
<!-- Copyright (c) 2019 Jonathan Redpath (legoboyvdlp) -->
|
||||
|
||||
<system name="A320: Pneumatic">
|
||||
<channel name="Startup">
|
||||
<channel name="Startup" execrate="8">
|
||||
|
||||
<switch name="/systems/startup-power-valves">
|
||||
<default value="0"/>
|
||||
|
@ -12,7 +12,7 @@
|
|||
|
||||
</channel>
|
||||
|
||||
<channel name="Valves">
|
||||
<channel name="Valves" execrate="8">
|
||||
|
||||
<!-- apu -->
|
||||
<switch name="/systems/pneumatics/valves/apu-bleed-valve-cmd">
|
||||
|
@ -604,7 +604,7 @@
|
|||
</actuator>
|
||||
</channel>
|
||||
|
||||
<channel name="Source PSI">
|
||||
<channel name="Source PSI" execrate="8">
|
||||
|
||||
<fcs_function name="/systems/pneumatics/source/apu-psi">
|
||||
<function>
|
||||
|
@ -749,7 +749,7 @@
|
|||
|
||||
</channel>
|
||||
|
||||
<channel name="System PSI">
|
||||
<channel name="System PSI" execrate="8">
|
||||
|
||||
<fcs_function name="/systems/pneumatics/psi/engine-1-upstream-src">
|
||||
<function>
|
||||
|
@ -924,7 +924,7 @@
|
|||
|
||||
</channel>
|
||||
|
||||
<channel name="Precooler Left" execute="/systems/pneumatics/indicating/bmc1-working"> <!-- These values come from BMC, so makes sense to not have them when BMC lacks power -->
|
||||
<channel name="Precooler Left" execute="/systems/pneumatics/indicating/bmc1-working" execrate="8"> <!-- These values come from BMC, so makes sense to not have them when BMC lacks power -->
|
||||
|
||||
<fcs_function name="/systems/pneumatics/precooler/calc/temp-1">
|
||||
<function>
|
||||
|
@ -1037,7 +1037,7 @@
|
|||
</switch>
|
||||
</channel>
|
||||
|
||||
<channel name="Precooler Right" execute="/systems/pneumatics/indicating/bmc2-working"> <!-- These values come from BMC, so makes sense to not have them when BMC lacks power -->
|
||||
<channel name="Precooler Right" execute="/systems/pneumatics/indicating/bmc2-working" execrate="8"> <!-- These values come from BMC, so makes sense to not have them when BMC lacks power -->
|
||||
|
||||
<fcs_function name="/systems/pneumatics/precooler/calc/temp-2">
|
||||
<function>
|
||||
|
@ -1150,7 +1150,7 @@
|
|||
</switch>
|
||||
</channel>
|
||||
|
||||
<channel name="ECAM">
|
||||
<channel name="ECAM" execrate="8">
|
||||
|
||||
<switch name="/systems/pneumatics/indicating/bmc1-working">
|
||||
<default value="0"/>
|
||||
|
|
|
@ -7,7 +7,7 @@
|
|||
|
||||
<property value="0">hydraulics/spoiler-l2/main-cmd-feedback</property>
|
||||
|
||||
<channel name="Spoiler Logic">
|
||||
<channel name="Spoiler Logic" execrate="2">
|
||||
|
||||
<switch name="spoilers/main-gear-or">
|
||||
<default value="0"/>
|
||||
|
|
Loading…