EMER ELEC - improve warning so that it deals correctly with APU available signal, GEN fault signals
This should reduce the number of transients. Also added a small 200ms delay
This commit is contained in:
parent
7dfd9f15ff
commit
34acba26f4
3 changed files with 24 additions and 11 deletions
|
@ -3564,13 +3564,13 @@ var messages_right_memo = func {
|
||||||
wing_aice.active = 0;
|
wing_aice.active = 0;
|
||||||
}
|
}
|
||||||
|
|
||||||
if (systems.PNEU.Switch.apu.getValue() == 1 and pts.APU.rpm.getValue() >= 95) {
|
if (systems.PNEU.Switch.apu.getValue() == 1 and systems.PNEU.Valves.apu.getValue() != 0 and systems.APUController.APU != nil and systems.APUController.APU.signals.available.getBoolValue()) {
|
||||||
apu_bleed.active = 1;
|
apu_bleed.active = 1;
|
||||||
} else {
|
} else {
|
||||||
apu_bleed.active = 0;
|
apu_bleed.active = 0;
|
||||||
}
|
}
|
||||||
|
|
||||||
if (apu_bleed.active == 0 and pts.APU.rpm.getValue() >= 95) {
|
if (apu_bleed.active == 0 and systems.APUController.APU != nil and systems.APUController.APU.signals.available.getBoolValue()) {
|
||||||
apu_avail.active = 1;
|
apu_avail.active = 1;
|
||||||
} else {
|
} else {
|
||||||
apu_avail.active = 0;
|
apu_avail.active = 0;
|
||||||
|
|
|
@ -2153,7 +2153,7 @@
|
||||||
|
|
||||||
<channel name="Emergency Electric Logic" execrate="8">
|
<channel name="Emergency Electric Logic" execrate="8">
|
||||||
|
|
||||||
<switch name="/systems/electrical/some-electric-thingie/emer-elec-config">
|
<switch name="/systems/electrical/some-electric-thingie/emer-elec-config-cmd">
|
||||||
<default value="0"/>
|
<default value="0"/>
|
||||||
<test logic="AND" value="1">
|
<test logic="AND" value="1">
|
||||||
/systems/electrical/bus/ac-1 lt 110
|
/systems/electrical/bus/ac-1 lt 110
|
||||||
|
@ -2163,20 +2163,33 @@
|
||||||
/systems/electrical/relay/ext-epc/contact-pos eq 0
|
/systems/electrical/relay/ext-epc/contact-pos eq 0
|
||||||
<test logic="OR">
|
<test logic="OR">
|
||||||
/controls/electrical/switches/gen-1 eq 0
|
/controls/electrical/switches/gen-1 eq 0
|
||||||
/systems/failures/electrical/gen-1 eq 1
|
/ECAM/warnings/logic/gen-1-inop eq 1
|
||||||
</test>
|
</test>
|
||||||
<test logic="OR">
|
<test logic="OR">
|
||||||
/controls/electrical/switches/gen-2 eq 0
|
/controls/electrical/switches/gen-2 eq 0
|
||||||
/systems/failures/electrical/gen-2 eq 1
|
/ECAM/warnings/logic/gen-2-inop eq 1
|
||||||
</test>
|
</test>
|
||||||
<test logic="OR">
|
<test logic="OR">
|
||||||
/controls/electrical/switches/apu eq 0
|
/controls/electrical/switches/apu eq 0
|
||||||
/systems/failures/electrical/apu eq 1
|
/ECAM/warnings/logic/apu-gen-fault eq 1
|
||||||
/engines/engine[2]/n1 lt 94.9
|
/systems/apu/available eq 0
|
||||||
</test>
|
</test>
|
||||||
</test>
|
</test>
|
||||||
</switch>
|
</switch>
|
||||||
|
|
||||||
|
<actuator name="/systems/electrical/some-electric-thingie/emer-elec-config-timer">
|
||||||
|
<input>/systems/electrical/some-electric-thingie/emer-elec-config-cmd</input>
|
||||||
|
<rate_limit sense="incr">5</rate_limit>
|
||||||
|
<rate_limit sense="decr">100</rate_limit>
|
||||||
|
</actuator>
|
||||||
|
|
||||||
|
<switch name="/systems/electrical/some-electric-thingie/emer-elec-config">
|
||||||
|
<default value="0"/>
|
||||||
|
<test logic="OR" value="1">
|
||||||
|
/systems/electrical/some-electric-thingie/emer-elec-config-timer eq 1
|
||||||
|
</test>
|
||||||
|
</switch>
|
||||||
|
|
||||||
<switch name="/systems/electrical/some-electric-thingie/emer-elec-config-generator-1-bustie">
|
<switch name="/systems/electrical/some-electric-thingie/emer-elec-config-generator-1-bustie">
|
||||||
<default value="0"/>
|
<default value="0"/>
|
||||||
<test logic="AND" value="1">
|
<test logic="AND" value="1">
|
||||||
|
|
|
@ -2822,7 +2822,7 @@
|
||||||
</test>
|
</test>
|
||||||
</switch>
|
</switch>
|
||||||
|
|
||||||
<switch name="/ECAM/warnings/logic/eng/dual-failure-5-sec-input">
|
<switch name="/ECAM/warnings/logic/eng/dual-failure-2-sec-input">
|
||||||
<default value="0"/>
|
<default value="0"/>
|
||||||
<test logic="AND" value="1">
|
<test logic="AND" value="1">
|
||||||
/engines/engine[0]/n2-actual lt 59.4
|
/engines/engine[0]/n2-actual lt 59.4
|
||||||
|
@ -2830,8 +2830,8 @@
|
||||||
</test>
|
</test>
|
||||||
</switch>
|
</switch>
|
||||||
|
|
||||||
<actuator name="/ECAM/warnings/logic/eng/dual-failure-5-sec">
|
<actuator name="/ECAM/warnings/logic/eng/dual-failure-2-sec">
|
||||||
<input>/ECAM/warnings/logic/eng/dual-failure-5-sec-input</input>
|
<input>/ECAM/warnings/logic/eng/dual-failure-2-sec-input</input>
|
||||||
<rate_limit sense="incr">0.5</rate_limit>
|
<rate_limit sense="incr">0.5</rate_limit>
|
||||||
<rate_limit sense="decr">100</rate_limit>
|
<rate_limit sense="decr">100</rate_limit>
|
||||||
</actuator>
|
</actuator>
|
||||||
|
@ -2859,7 +2859,7 @@
|
||||||
/controls/engines/engine[0]/cutoff-switch eq 1
|
/controls/engines/engine[0]/cutoff-switch eq 1
|
||||||
/controls/engines/engine[1]/cutoff-switch eq 1
|
/controls/engines/engine[1]/cutoff-switch eq 1
|
||||||
</test>
|
</test>
|
||||||
/ECAM/warnings/logic/eng/dual-failure-5-sec eq 1
|
/ECAM/warnings/logic/eng/dual-failure-2-sec eq 1
|
||||||
</test>
|
</test>
|
||||||
</test>
|
</test>
|
||||||
</switch>
|
</switch>
|
||||||
|
|