1
0
Fork 0
A320-family/Systems/a320-aircond.xml

335 lines
10 KiB
XML
Raw Normal View History

2020-05-12 23:44:03 +00:00
<!-- Copyright (c) 2019 Jonathan Redpath (legoboyvdlp) -->
<system name="A320: Air Conditioning">
<channel name="Valves">
<switch name="/systems/air-conditioning/valves/flow-control-valve-1-cmd">
<default value="0"/>
<test logic="OR" value="0">
/controls/engines/engine[0]/fire-btn eq 1
<test logic="OR">
<test logic="AND">
<test logic="OR">
/systems/pneumatics/valves/starter-valve-1 ne 0
/systems/pneumatics/valves/starter-valve-2 ne 0
</test>
/gear/gear[1]/wow eq 1
</test>
<test logic="AND">
<test logic="OR">
/systems/pneumatics/valves/starter-valve-1 ne 0
<test logic="AND">
/systems/pneumatics/valves/crossbleed-valve eq 1
/systems/pneumatics/valves/starter-valve-2 ne 0
</test>
</test>
/gear/gear[1]/wow eq 0
</test>
</test>
/systems/pressurization/ditchingpb eq 1
/systems/pneumatics/psi/engine-1-psi le 13.8
</test>
<test logic="AND" value="1">
/controls/pneumatics/switches/pack-1 eq 1
</test>
</switch>
<switch name="/systems/air-conditioning/valves/flow-control-valve-1-power">
<default value="0"/>
<test logic="AND" value="5">
/systems/failures/pneumatics/pack-1-valve eq 0
/systems/electrical/bus/dc-ess-shed ge 25
</test>
</switch>
<actuator name="/systems/air-conditioning/valves/flow-control-valve-1">
<input>/systems/air-conditioning/valves/flow-control-valve-1-cmd</input>
<rate_limit>/systems/air-conditioning/valves/flow-control-valve-1-power</rate_limit>
</actuator>
<switch name="/systems/air-conditioning/valves/flow-control-valve-2-cmd">
<default value="0"/>
<test logic="OR" value="0">
/controls/engines/engine[1]/fire-btn eq 1
<test logic="OR">
<test logic="AND">
<test logic="OR">
/systems/pneumatics/valves/starter-valve-1 ne 0
/systems/pneumatics/valves/starter-valve-2 ne 0
</test>
/gear/gear[1]/wow eq 1
</test>
<test logic="AND">
<test logic="OR">
/systems/pneumatics/valves/starter-valve-2 ne 0
<test logic="AND">
/systems/pneumatics/valves/crossbleed-valve eq 1
/systems/pneumatics/valves/starter-valve-1 ne 0
</test>
</test>
/gear/gear[1]/wow eq 0
</test>
</test>
/systems/pressurization/ditchingpb eq 1
/systems/pneumatics/psi/engine-2-psi le 13.8
2020-05-12 23:44:03 +00:00
</test>
<test logic="AND" value="1">
/controls/pneumatics/switches/pack-2 eq 1
</test>
</switch>
<switch name="/systems/air-conditioning/valves/flow-control-valve-2-power">
<default value="0"/>
<test logic="AND" value="5">
/systems/failures/pneumatics/pack-2-valve eq 0
/systems/electrical/bus/dc-2 ge 25
</test>
</switch>
<actuator name="/systems/air-conditioning/valves/flow-control-valve-2">
<input>/systems/air-conditioning/valves/flow-control-valve-2-cmd</input>
<rate_limit>/systems/air-conditioning/valves/flow-control-valve-2-power</rate_limit>
</actuator>
</channel>
<channel name="Packs">
<switch name="/systems/air-conditioning/packs/single-pack">
<default value="0"/>
<test logic="OR" value="1">
<test logic="AND">
/systems/air-conditioning/valves/flow-control-valve-1 eq 0
/systems/air-conditioning/valves/flow-control-valve-2 eq 1
</test>
<test logic="AND">
/systems/air-conditioning/valves/flow-control-valve-1 eq 1
/systems/air-conditioning/valves/flow-control-valve-2 eq 0
</test>
</test>
</switch>
<switch name="/systems/air-conditioning/packs/pack-flow">
<default value="/controls/pneumatics/switches/pack-flow"/>
<test logic="OR" value="1.2">
/systems/pneumatics/valves/apu-bleed-valve eq 1
/systems/air-conditioning/packs/single-pack eq 1
</test>
</switch>
<fcs_function name="/systems/air-conditioning/packs/pack-flow-1-calc">
<function>
<product>
<property>/systems/air-conditioning/valves/flow-control-valve-1</property>
<property>/systems/air-conditioning/packs/pack-flow</property>
</product>
</function>
</fcs_function>
<lag_filter name="/systems/air-conditioning/packs/pack-flow-1">
<input>/systems/air-conditioning/packs/pack-flow-1-calc</input>
<c1>5</c1>
</lag_filter>
<fcs_function name="/systems/air-conditioning/packs/pack-flow-2-calc">
<function>
<product>
<property>/systems/air-conditioning/valves/flow-control-valve-2</property>
<property>/systems/air-conditioning/packs/pack-flow</property>
</product>
</function>
</fcs_function>
<lag_filter name="/systems/air-conditioning/packs/pack-flow-2">
<input>/systems/air-conditioning/packs/pack-flow-2-calc</input>
<c1>5</c1>
</lag_filter>
2020-05-12 23:44:03 +00:00
<switch name="/systems/air-conditioning/packs/pack-factor">
<default value="0"/>
<test logic="AND" value="0.0">
/systems/air-conditioning/valves/flow-control-valve-1 eq 0
/systems/air-conditioning/valves/flow-control-valve-2 eq 0
</test>
<test logic="OR" value="0.6">
/systems/air-conditioning/valves/flow-control-valve-1 eq 0
/systems/air-conditioning/valves/flow-control-valve-2 eq 0
</test>
<test logic="AND" value="1.0">
/systems/air-conditioning/valves/flow-control-valve-1 eq 1
/systems/air-conditioning/valves/flow-control-valve-2 eq 1
</test>
</switch>
2020-05-14 09:39:25 +00:00
<fcs_function name="/systems/air-conditioning/packs/pack-1-outlet-temp-calc">
<function>
2020-05-14 09:39:25 +00:00
<ifthen>
<gt>
<property>/systems/air-conditioning/valves/flow-control-valve-1</property>
<value>0.5</value>
</gt>
<product>
<value>0.6363636</value>
<property>/systems/air-conditioning/valves/flow-control-valve-1</property>
<property>/systems/pneumatics/precooler/temp-1</property>
</product>
<property>/systems/navigation/probes/tat-1/compute-tat</property>
</ifthen>
</function>
</fcs_function>
2020-05-14 09:39:25 +00:00
<lag_filter name="/systems/air-conditioning/packs/pack-1-outlet-temp">
<input>/systems/air-conditioning/packs/pack-1-outlet-temp-calc</input>
<c1>0.8</c1>
</lag_filter>
<fcs_function name="/systems/air-conditioning/packs/pack-2-outlet-temp-calc">
<function>
2020-05-14 09:39:25 +00:00
<ifthen>
<gt>
<property>/systems/air-conditioning/valves/flow-control-valve-2</property>
<value>0.5</value>
</gt>
<product>
<value>0.6363636</value>
<property>/systems/air-conditioning/valves/flow-control-valve-2</property>
<property>/systems/pneumatics/precooler/temp-2</property>
</product>
<property>/systems/navigation/probes/tat-2/compute-tat</property>
</ifthen>
</function>
</fcs_function>
2020-05-14 09:39:25 +00:00
<lag_filter name="/systems/air-conditioning/packs/pack-2-outlet-temp">
<input>/systems/air-conditioning/packs/pack-2-outlet-temp-calc</input>
<c1>0.8</c1>
</lag_filter>
<fcs_function name="/systems/air-conditioning/packs/pack-1-output-temp-calc">
<function>
2020-05-14 09:39:25 +00:00
<ifthen>
<gt>
2020-05-14 10:42:45 +00:00
<property>/systems/air-conditioning/valves/flow-control-valve-1</property>
2020-05-14 09:39:25 +00:00
<value>0.5</value>
</gt>
<sum>
<product>
<value>-1</value>
<sum>
<product>
<value>0.76</value>
<property>/systems/air-conditioning/packs/pack-1-outlet-temp</property>
</product>
<value>37.5</value>
</sum>
</product>
<property>/systems/air-conditioning/packs/pack-1-outlet-temp</property>
</sum>
2020-05-14 10:42:45 +00:00
<property>/systems/navigation/probes/tat-1/compute-tat</property>
2020-05-14 09:39:25 +00:00
</ifthen>
</function>
</fcs_function>
2020-05-14 09:39:25 +00:00
<lag_filter name="/systems/air-conditioning/packs/pack-1-output-temp">
<input>/systems/air-conditioning/packs/pack-1-output-temp-calc</input>
<c1>0.8</c1>
</lag_filter>
<fcs_function name="/systems/air-conditioning/packs/pack-2-output-temp-calc">
<function>
2020-05-14 09:39:25 +00:00
<ifthen>
<gt>
<property>/systems/air-conditioning/valves/flow-control-valve-2</property>
<value>0.5</value>
</gt>
<sum>
<product>
<value>-1</value>
<sum>
<product>
<value>0.76</value>
<property>/systems/air-conditioning/packs/pack-2-outlet-temp</property>
</product>
<value>37.5</value>
</sum>
</product>
<property>/systems/air-conditioning/packs/pack-2-outlet-temp</property>
</sum>
<property>/systems/navigation/probes/tat-2/compute-tat</property>
</ifthen>
</function>
</fcs_function>
2020-05-14 09:39:25 +00:00
<lag_filter name="/systems/air-conditioning/packs/pack-2-output-temp">
<input>/systems/air-conditioning/packs/pack-2-output-temp-calc</input>
<c1>0.8</c1>
</lag_filter>
</channel>
<channel name="Recirculation">
2020-05-12 23:44:03 +00:00
</channel>
<channel name="Mass flow">
<fcs_function name="/systems/air-conditioning/mass-flow-fresh-kg_s">
<function>
<quotient>
<product>
<property>/systems/air-conditioning/packs/pack-factor</property>
<property>/systems/air-conditioning/packs/pack-flow</property>
<product>
<property>/systems/pressurization/cabinpsi</property>
<value>68.9476</value>
</product>
<value>0.928</value>
</product>
<product>
<value>2.87</value>
<property>/systems/air-conditioning/temperatures/cabin-overall-temp-kelvin</property>
</product>
</quotient>
</function>
</fcs_function>
<switch name="/systems/air-conditioning/recirc/recirc-factor">
<default value="0"/>
<test logic="AND" value="0.738095">
/systems/air-conditioning/packs/pack-flow eq 1.0
</test>
<test logic="OR" value="0.5686275">
/systems/air-conditioning/packs/pack-flow eq 1.2
</test>
<test logic="AND" value="0.93998">
/systems/air-conditioning/packs/pack-flow eq 0.8
</test>
</switch>
<fcs_function name="/systems/air-conditioning/mass-flow-total-kg_s">
<function>
<sum>
<product>
<property>/systems/air-conditioning/recirc/recirc-factor</property>
<property>/systems/air-conditioning/recirc/recirc-fans</property>
<property>/systems/air-conditioning/mass-flow-fresh-kg_s</property>
</product>
<property>/systems/air-conditioning/mass-flow-fresh-kg_s</property>
</sum>
</function>
</fcs_function>
<fcs_function name="/systems/air-conditioning/mass-flow-cockpit-kg_s">
<function>
<product>
<value>0.14</value>
<property>/systems/air-conditioning/mass-flow-total-kg_s</property>
</product>
</function>
</fcs_function>
</channel>